Display: CRT event link error Used by: Cause: Unable to link the CRT event. Remedy: Re-execute the function. If the error recurs, re-boot MCS. ------------------------------ Code: 2100750A Display: MTT file get error Use…
Remedy: If doing a direct start-up, check the start-up option.
------------------------------
Code: 21007501
Display: Illegal parameter
Used by:
Cause: The startup parameter is illegal.
Remedy: If doing a direct start-up, check the start-up parameters.
------------------------------
Code: 21007502
Display: Illegal base position (ST1)
Used by:
Cause: The reference device is out of range.
Remedy: Station 1 includes devices 1~35. Specify within this range.
------------------------------
Code: 21007503
Display: Illegal base position (ST2)
Used by:
Cause: The reference device is out of range.
Remedy: Station 1 includes devices 41~45. Specify within this range.
------------------------------
Code: 21007504
Display: Illegal base position (TRAY_R)
Used by:
Cause: The reference device is out of range.
Remedy: TRAY_R includes devices 101~110. Specify within this range.
------------------------------
Code: 21007505
Display: Illegal base position (TRAY_L)
Used by:
Cause: The reference device is out of range.
Remedy: TRAY_L includes devices 111~120. Specify within this range.
------------------------------
Code: 21007506
Display: Message file read error
Used by:
Cause: Unable to read the message file.
Remedy: Re-boot MCS.
------------------------------
Code: 21007507
Display: Read pipe create error
Used by:
Cause: Unable to create the pipe.
Remedy: Re-install the software.
------------------------------
Code: 21007508
Display: Write pipe create error
Used by:
Cause: Unable to create the pipe.
Remedy: Re-install the software.
------------------------------
Code: 21007509
第 1938 页
Display: CRT event link error
Used by:
Cause: Unable to link the CRT event.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 2100750A
Display: MTT file get error
Used by:
Cause: Unable to read the system (MTT) file.
Remedy: Re-install the software.
------------------------------
Code: 2100750B
Display: MTT file not found
Used by:
Cause: MTT file not found.
Remedy: Re-install the software.
------------------------------
Code: 2100750C
Display: MTT file open error
Used by:
Cause: Unable to open the machine type table.
Remedy: Re-install the system.
------------------------------
Code: 2100750D
Display: Memory is full
Used by:
Cause: Unable to allocate memory.
Remedy: Re-boot MCS.
------------------------------
Code: 2100750E
Display: MTT file seek error
Used by:
Cause: Unable to seek the file.
Remedy: Re-install the software.
------------------------------
Code: 2100750F
Display: Production file not found
Used by:
Cause: Unable to find the production program.
Remedy: Check the filename and the file.
------------------------------
Code: 21007510
Display: Production file open error
Used by:
Cause: Unable to open the production file.
Remedy: Check the file.
------------------------------
Code: 21007511
Display: Program machine type unmatched
Used by:
Cause: The production program's machine type is wrong.
第 1939 页
Remedy: Check the file.
------------------------------
Code: 21007512
Display: Production file read err
Used by:
Cause: Unable to read the production file.
Remedy: Check the file.
------------------------------
Code: 21007513
Display: No entry Machine type
Used by:
Cause: No machine type has been entered.
Remedy: Check the file.
------------------------------
Code: 21007514
Display: Part data read error
Used by:
Cause: Unable to read Part data.
Remedy: Check the file.
------------------------------
Code: 21007515
Display: Cartridge name create err
Used by:
Cause: Unable to create feeder names.
Remedy: Check that the information in Part data's Package_and_appearance_data is entered correctly.
------------------------------
Code: 21007516
Display: Cartridge data read error
Used by:
Cause: Unable to read feeder data.
Remedy: Check the Part data file.
------------------------------
Code: 21007517
Display: No entry Tray type
Used by:
Cause: The tray type has not been specified.
Remedy: Check the Part data file.
------------------------------
Code: 21007518
Display: No entry Cartridge type
Used by:
Cause: The feeder type has not been specified.
Remedy: Check the Part data file.
------------------------------
Code: 21007519
Display: Dequeing error
Used by:
Cause: Unable to de-queue memory.
Remedy: Re-boot MCS.
------------------------------
Code: 2100751A