FUJI错误代码查询.pdf - 第171页

Remedy: Confirm that the Proper data item 526: [PM] Creep Speed Z was set. If not, input correct data. ------------------------------ Code: 11022A16 Display: 11022A16 Used by: Cause: One of the settings H_X, M_X, L_X for…

100%1 / 5282
Cause: The pulse count for the PI-axis plus direction limit was not set.
Remedy: Specify the correct data for 143. Max Limit Position PI in Proper data.
------------------------------
Code: 11022A0C
Display: 11022A0C
Used by: QP132
Cause: The pulse count for the PO-axis plus direction limit was not set.
Remedy: Specify the correct data for 166. Max Limit Position PO in Proper data.
------------------------------
Code: 11022A0D
Display: 11022A0D
Used by: QP132
Cause: The pulse count for the F-axis plus direction limit was not set.
Remedy: Specify the correct data for 145. Max Limit Position F in Proper data.
------------------------------
Code: 11022A0E
Display: 11022A0E
Used by:
Cause: The X-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 520: [PM] Zero Setup Speed X is set. If not, input correct data.
------------------------------
Code: 11022A0F
Display: 11022A0F
Used by:
Cause: The Y-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 521: [PM]Zero Setup Speed Y was set. If not, input correct
data.
------------------------------
Code: 11022A11
Display: 11022A11
Used by:
Cause: The Z-axis servo zero setting speed was not specified in PM Proper data.
Remedy: Confirm that the Proper data item 522: [PM] Zero Setup Speed Z was set. If not, input correct
data.
------------------------------
Code: 11022A12
Display: 11022A12
Used by:
Cause: The creep speed for X-axis servo zero setting was not specified in the common PM Proper data.
Remedy: Confirm that the Proper data item 524: [PM] Creep Speed X was set. If not, input correct data.
------------------------------
Code: 11022A13
Display: 11022A13
Used by:
Cause: The creep speed for Y-axis servo zero setting was not specified in the common PM Proper data.
Remedy: Confirm that the Proper data item 525: [PM] Creep Speed Y was set. If not, input correct data.
------------------------------
Code: 11022A15
Display: 11022A15
Used by:
Cause: The creep speed for Z-axis servo zero setting was not specified in the common PM Proper data.
第 170 页
Remedy: Confirm that the Proper data item 526: [PM] Creep Speed Z was set. If not, input correct data.
------------------------------
Code: 11022A16
Display: 11022A16
Used by:
Cause: One of the settings H_X, M_X, L_X for the X-axis movement speed was not specified in the
common PM Proper data.
Remedy: Confirm that the Proper data items 528: [PM] Move Speed H_X, 529: [PM] M_X, and 530: [PM]
Move speed L_X are set. If not, input correct data.
------------------------------
Code: 11022A17
Display: 11022A17
Used by:
Cause: One of the settings H_Y, M_Y, L_Y for the Y-axis movement speed was not specified in the
common PM Proper data.
Remedy: Confirm that the Proper data items 531: [PM] Move Speed H_Y, 532: [PM] M_Y, and 533: [PM]
Move speed L_Y are set. If not, input correct data.
------------------------------
Code: 11022A18
Display: 11022A18
Used by:
Cause: One of the settings H_Q, M_Q, L_Q for the Q-axis movement speed was not specified in the
common PM Proper data.
Remedy: Confirm that the Proper data items 537: [PM] Move Speed H_Q, 538: [PM] M_Q, and 539: [PM]
Move speed L_Q are set. If not, input correct data.
------------------------------
Code: 11022A19
Display: 11022A19
Used by:
Cause: One of the settings H_Z, M_Z, L_Z for the Z-axis movement speed was not specified in the
common PM Proper data.
Remedy: Confirm that the Proper data items 534: [PM] Move Speed H_Z, 535: [PM] M_Z, and 536: [PM]
Move speed L_Z are set. If not, input correct data.
------------------------------
Code: 11022A1A
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The transmitted Proper data indicates a different machine type.
Remedy: Use F4G to retransmit the Proper data for the machine in question.
------------------------------
Code: 11022A1B
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The specified PLM quantity is outside the valid range.
Remedy: Set a value from 1 to 6 for "The Number of PLM (QP2)" in the Proper data.
------------------------------
Code: 11022A1C
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: A value has not been set for the PLM servo counter output interval.
Remedy: Set a value of 1 or greater for the "Counter Output Interval (QP2)" parameter in the Proper data.
第 171 页
------------------------------
Code: 11022A1D
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The board quantity specified for vision processing is outside the valid range.
Remedy: Set a value from 1 to 6 for "The Number of Vision Processor (QP2)" in the Proper data.
------------------------------
Code: 11022A1E
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Parts Camera Type (QP2)" setting (which indicates the vision processing camera type)
is outside the valid range. The value for the "?" in the parameter name indicates the module number.
Remedy: Set the correct camera type for the "PLM? Parts Camera Type (QP2)" parameter in the Proper
data.
------------------------------
Code: 11022A1F
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Mark Camera MPX ch. No. (QP2)" setting (which indicates the number of the
multiplexer port that the mark camera is connected to) either is outside the valid range, or duplicates
another setting. The value for the "?" in the parameter name indicates the module number.
Remedy: Set the correct port number (a value from 1 to 12) for the "PLM? Mark Camera MPX ch. No.
(QP2)" parameter in the Proper data.
------------------------------
Code: 11022A20
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? Parts Camera MPX ch. No. (QP2)" setting (which indicates the number of the
multiplexer port that the RS vision processing camera is connected to) either is outside the valid range, or
duplicates another setting. The value for the "?" in the parameter name indicates the module number.
Remedy: Set the correct port number (a value from 1 to 12) for the "PLM? Parts Camera MPX ch. No.
(QP2)" parameter in the Proper data.
------------------------------
Code: 11022A21
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? LSO ch. No. (QP2)" setting (which indicates the number of the LSO board port that the
LS vision processing camera is connected to) either is outside the valid range, or duplicates another
setting. The value for the "?" in the parameter name indicates the module number.
Remedy: Set the correct port number (a value from 1 to 4) for the "PLM? LSO ch. No. (QP2)" parameter in
the Proper data.
------------------------------
Code: 11022A22
Display: Same as code
Used by: QP242,QP201,QP202,QP203
Cause: The "PLM? LSO board No. (QP2)" setting (which indicates the number of the LSO board that the
LS vision processing camera is connected to) is outside the valid range. The value for the "?" in the
parameter name indicates the module number.
Remedy: Set the correct board number (either 1 or 2) for the "PLM? LSO board No. (QP2)" parameter in
the Proper data.
------------------------------
第 172 页