FUJI错误代码查询.pdf - 第1454页

data. ------------------------------ Code: 1D14F??? Display: Used by: Cause: There was a logical error in the management program. Remedy: Check Part data. ------------------------------ Code: 1D150002 Display: Used by: C…

100%1 / 5282
Used by:
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D14C4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D14C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D14C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D14C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D14D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D14D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D14E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
第 1453 页
data.
------------------------------
Code: 1D14F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D150002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D154001
Display:
Used by:
Cause: This Vision number is unsupported.
Remedy: It is necessary to upgrade the software.
------------------------------
Code: 1D154007
Display:
Used by:
Cause: There are 2~4 leads more than set in Part data.
Remedy: Check the setting in Part data.
------------------------------
Code: 1D154009
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D15400A
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D15400B
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D15400C
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D15400D
第 1454 页
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D15400E
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D15400F
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D154010
Display:
Used by:
Cause: The lead width is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D154011
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D154012
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D154013
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the part shape, check that the part is being picked properly, and check the image taken
by vision processing.
------------------------------
Code: 1D158002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D158100