FUJI错误代码查询.pdf - 第590页
Display: Interlock Top cleaner Supply Solder Used by: GP551 Cause: The solder supply unit (SSD-axis) and the upper cleaner may collide. This error occurs when the solder supply unit (SSD-axis) is not at the retract posit…
Code: 12056120
Display: "Move squeegee head to escape position."
Used by: GP551
Cause: The squeegee head is not at the lock position.
Remedy: Move the squeegee head to the lock position.
------------------------------
Code: 12056121
Display: Move camera to lower cleaner coupling position
Used by: GP551
Cause: The lower cleaner coupler is not in position.
Remedy: Move the camera or the lower cleaner coupler into position.
------------------------------
Code: 12056122
Display: Move lower cleaner to retract position
Used by: GP551
Cause: The lower cleaner is not at its retract position.
Remedy: Move the lower cleaner to its retract position.
------------------------------
Code: 12056123
Display: 联锁 (Z|Y)轴 电路板通过确认
[Interlock (Z|Y)axis ]
Used by: GP551,GPX,NXTP
Cause: 在移动所显示的轴时,IN-MAIN搬运轨道的电路板换乘确认传感器或MAIN-OUT搬运轨道的电路板换乘确认
传感器因为确认了电路板,所以不能够移动平台。
Remedy: 请从搬运轨道上除去电路板。或者,请确认平台移动许可确认传感器的ON/OFF动作。
<img src="$LKEY_ERRIMG_MC$/12056123.PNG">
------------------------------
Code: 12056124
Display: "Interlock CX axis Z axis"
Used by: GP551
Cause: The Z-axis may interfere with the CX-axis. This error occurs if the CX-axis is moved while the Z-
axis is not at the escape position.
Remedy: Move the Z-axis to the escape position. If necessary, make sure that the Z-axis escape position
check sensor is functioning normally.
------------------------------
Code: 12056125
Display: Interlock Camera/Non-retracted Upper|Lower Cleaner
Used by: GP551
Cause: The cleaner has not been stowed. This error occurs during the coupling of the camera axis and
cleaner, if an attempt is made to move the camera axis when the cleaner is not in the stored position.
Remedy: Move the cleaner to the stored position. Alternatively, check the cleaner storage sensor.
------------------------------
Code: 12056126
Display: "Interlock S axis"
Used by: GP551
Cause: The S-axis may interfere with the upper cleaner. This error occurs if the cleaner drive axis is
moved while the S-axis is not at the escape position.
Remedy: Move the S-axis to the escape position. If necessary, make sure that the S-axis escape position
check sensor is functioning normally.
------------------------------
Code: 12056127
第 589 页
Display: Interlock Top cleaner Supply Solder
Used by: GP551
Cause: The solder supply unit (SSD-axis) and the upper cleaner may collide. This error occurs when the
solder supply unit (SSD-axis) is not at the retract position and the cleaner axis is moving.
Remedy: Move the solder supply unit (SSD-axis) to the retract position. Alternatively, check the on/off
status of the SSD-axis' retract position sensor.
------------------------------
Code: 12056128
Display: 联锁 相机 下清洁器连结
[Interlock Camera ]
Used by: GP551,GPX
Cause: CX轴与下清洁器连结着。在CY轴移动时CX轴与下清洁器处于连结状态的情况下发生。 存在清洁器和相
机机械手发生了干涉的可能性。 (GPX)
Remedy: 请解除CX轴与下清洁器的连结。或者,请确认下清洁器连结、下清洁器/相机轴接近的各确认传感器的
ON/OFF动作。 1.请用手将清洁器移动到退避位置。
2.发生了干涉时,请与本公司的Support联系。(GPX)
<img src="$LKEY_ERRIMG_MC$/EI0021.bmp">
------------------------------
Code: 12056129
Display: Interlock S axis Solder Pusher
Used by: GP551
Cause: This error occurs when the S-axis moves while the solder pusher is down.
Remedy: Raise the solder pusher. Alternatively, check the on/off status of the solder pusher's up
position/down position sensors.
------------------------------
Code: 1205612A
Display: Interlock S axis SQG Open/Close
Used by: GP551
Cause: This error occurs when the S-axis moves while the squeegee head is opened.
Remedy: Close the squeegee head. Alternatively, check the on/off status of the squeegee head's
open/closed sensors.
------------------------------
Code: 1205612B
Display: "Interlock S axis"
Used by: GP551
Cause: This error occurs if the S-axis is moved while the squeegee head is not stored.
Remedy: Store the squeegee head. If necessary, make sure that the squeegee head storage check sensor
is functioning normally.
------------------------------
Code: 1205612C
Display: Interlock Y axis Z axis
Used by: GP551
Cause: This error occurs if the Y-axis moves when the Z-axis is not at the retract position.In order to
detect an abnormal board width, the Y-axis can only move when the Z-axis is at the retract position.
Remedy: Move the Z-axis to the retract position. Alternatively, check the on/off status of the Z-axis'
retract position sensor.
------------------------------
Code: 1205612D
Display: Interlock Y axis Main Stopper
Used by: GP551,NXTP
Cause: This error occurs when the Y-axis moves while the main stopper is down.
第 590 页
Remedy: Raise the main stopper. Alternatively, check the on/off status of the main conveyor stopper's
engaged/disengaged sensors.
<img src="$LKEY_ERRIMG_MC$/1205612D.PNG">
------------------------------
Code: 1205612E
Display: Interlock Y axis Push Plate
Used by: GP551
Cause: The push plate is down. This error occurs if the Y-axis moves when the push plate is down.
Remedy: Raise the push plate.Alternatively, check the on/off status of the push plate's raised
position/lowered position sensors.
------------------------------
Code: 1205612F
Display: Interlock Y axis/Frame
Used by: GP551
Cause: To prevent the side clamp from colliding with the frame, the Y-axis cannot be moved.
Remedy: Lower the Z-axis until the lower limit sensor comes on. Alternatively, check the on/off status of
the sensor. (X034Y AXIS ILK)
------------------------------
Code: 12056130
Display: InterlockComp axis/Screen Clamp
Used by: GP551
Cause: This error occurs when the compensation axis moves while the upper clamp is engaged.
Remedy: Unclamp the screen. Alternatively, check the on/off status of the screen's upper clamp
clamped/unclamped sensor.
------------------------------
Code: 12056131
Display: "Interlock Supply Solder S axis"
Used by: GP551
Cause: The S-axis may interfere with the solder supply unit (SSD-axis). This error occurs if the solder
supply unit (SSD-axis) is moved while the S-axis is not at the escape position.
Remedy: Move the S-axis to the escape position. If necessary, make sure that the S-axis escape position
check sensor is functioning normally.
------------------------------
Code: 12056132
Display: Interlock Supply Solder Top Cleaner
Used by: GP551
Cause: The top cleaner and the solder supply unit (SSD-axis) may collide. This error occurs if the solder
supply unit moves when the top cleaner is not at its origin position.
Remedy: Move the top cleaner to its origin position. Alternatively, check the on/off status of the top
cleaner's origin position sensor.
------------------------------
Code: 12056133
Display: 联锁 Z轴 下清洁器及相机
Used by: GP551,GPX
Cause: Z轴与下清洁器及相机(CX轴)发生了干涉。或者,有可能发生干涉。在Z轴启动时下清洁器在原位置及
相机(CX轴)不在待机位置的情况下发生。
Remedy: 请将下清洁器移动到原位置,将相机(CX轴)移动到待机位置。或者,请确认下清洁器原位置确认传感器
、CX轴相机待机确认传感器的ON/OFF动作。
------------------------------
Code: 12056134
Display: Interlock Y-axis Camera
第 591 页