Cause: The machine attempted to move the pallet in the IN station, the stopper has not been turned off. Remedy: Make sure that both the stopper is functioning normally. Check the stopper OFF limit sensor. ---------------…

100%1 / 5282
Remedy: Press the reset button at servo box 3.
------------------------------
Code: 12052109
Display: Servo Not Ready(CP5)
Servo system error!(NP2,QP3)
Used by:
Cause: The servo board is not ready.
Servo system error!(NP2,QP3)
Remedy: Cut the power supply and reboot the machine.
Turn the power to the machine off and restart the machine.(NP2,QP3)
------------------------------
Code: 12052110
Display: Servo amp Alarm
Used by:
CP4,CP42,CP43,CP6,CP6M,CP65,CP652C,CP642,CP642M,CP643,NP132.NP133,NP134,NP153,NP2,QP3
Cause: The servo amp is not functioning correctly.
Remedy: Check the servo amp.
------------------------------
Code: 12052111
Display: 软件限位范围外
Used by: NP2,QP3,NP133,NP134,NP153,GPX,NXTP
Cause: 参数部所显示的轴的移动目的值超出了固有值的移动范围。
Remedy: 请确认移动目的位置及固有值的能够移动的范围。
------------------------------
Code: 12052112
Display: A deviation overflow error occurred.
Used by: NP2,QP3
Cause: The target position for the axis displayed in the parameter section falls outside the travel range.
Remedy: Check the target position or travel range specified in machine calibration data.
------------------------------
Code: 12052113
Display: Z-axis positioning error!
Used by: NP2,QP3
Cause: Z-axis movement was aborted due to an error.
Remedy: Check if Z-axis movement is particularly heavy and check for servo amp errors.
------------------------------
Code: 12054001
Display: Plt Unclamp Error DF
Used by: CP5
Cause: Unclamp error at the DF axis pallet.
Remedy: Check the movement of the DF axis pallet clamp, and check the lower edge.
------------------------------
Code: 12054002
Display: Plt Unclamp Error DR
Used by: CP5
Cause: Unclamp error at the DR axis pallet.
Remedy: Check the movement of the DR axis pallet clamp, and check the lower edge.
------------------------------
Code: 12054003
Display: "Pallet IN stn stopper error"
Used by: CP5
第 542 页
Cause: The machine attempted to move the pallet in the IN station, the stopper has not been turned off.
Remedy: Make sure that both the stopper is functioning normally. Check the stopper OFF limit sensor.
------------------------------
Code: 12054004
Display: "Pallet clamp error: DF IN stn"
Used by: CP5
Cause: The DF-axis has failed to clamp a pallet at the pallet IN station.
Remedy: Make sure the DF-axis pallet clamp is functioning normally. Check the upper limit and clamp
check sensors.
------------------------------
Code: 12054005
Display: "Pallet clamp error: DR IN stn"
Used by: CP5
Cause: The DR-axis failed to clamp a pallet at the pallet IN station.
Remedy: Make sure the DR-axis pallet clamp is functioning normally. Check the upper limit and clamp
check sensors.
------------------------------
Code: 12054006
Display: CHECK CLUTCH
Used by: CP3,CP4-1,CP4-2
Cause: There was a clutch movement alarm (CP3).
Remedy: Check the clutch.
------------------------------
Code: 12054007
Display: "Cycle alarm: carrier" (IP)
Used by: IP1
Cause: A problem has occurred in the tray component carrier cylinder system.
Remedy: Adjust the carrier cylinder so that it is capable of moving forward and retracting. Confirm that
the carrier's forward end and retract end sensors are functioning normally.
------------------------------
Code: 12054008
Display: "Cycle alarm: sub nozzle" (IP)
Used by: IP1
Cause: A problem has occurred in the subrobot nozzle cylinder system.
Remedy: Adjust the subrobot nozzle cylinder so that it is capable of moving up and down. Confirm that
the subrobot nozzle's upper and lower limit sensors are functioning normally.
------------------------------
Code: 12054009
Display: Cycle Alarm Tray Remover
Used by: IP1
Cause: There was a tray removal cylinder alarm.
Remedy: Adjust the advanced and retracted positions of the tray removal cylinder.
------------------------------
Code: 1205400A
Display: Cycle Alarm Error conveyor
Used by: IP1,IP2,IP3
Cause: There was a rejected parts conveyor alarm.
Remedy: Adjust the operating ability of the rejected parts conveyor motor.
------------------------------
Code: 1205400B
Display: "Cycle alarm: feeder" (IP,IP2)
第 543 页
Used by: IP1,IP2,IP3
Cause: An alarm has occurred in a stick feeder or tape feeder cylinder system.
Remedy: Adjust the stick or tape feeder cylinder so that it is capable of moving forward and retracting.
------------------------------
Code: 1205400C
Display: PCM OUT Cylinder Time Out
Used by: CP5
Cause: The palette was not successfully unloaded from the out station to the down lifter.
Remedy: Check the PCM's out cylinder as well as the out cylinder's extended position.
------------------------------
Code: 12054010
Display: Cycle Alarm NOZZLE SHUTTER(IP)
Shutter(IP2)
Nozzle shutter error!(NP2,QP3)
Used by: IP1,IP2,NP2,QP3
Cause: There was a nozzle shutter cylinder alarm.
The nozzle shutter failed to open within the specified time (time-out error).(NP2,QP3)
Remedy: Adjust the advanced and retracted positions of the nozzle shutter cylinder.
Check the action of the nozzle shutter.(NP2,QP3)
------------------------------
Code: 12054012
Display: Cycle Alarm NOZZLE SHIFT
Used by: IP1,IP2
Cause: There was a nozzle shift cylinder alarm.
Remedy: Adjust the advanced and retracted positions of the nozzle shift cylinder.
------------------------------
Code: 12054013
Display: Cycle Alarm Holder1
Used by: IP2
Cause: There was a holder 1 cylinder alarm.
Remedy: Adjust the advanced and retracted positions of the nozzle shutter cylinder.
------------------------------
Code: 12054014
Display: Cycle Alarm Holder2
Used by: IP2
Cause: There was a holder 2 cylinder alarm.
Remedy: Adjust the advanced and retracted positions of the holder 2 cylinder.
------------------------------
Code: 12054015
Display: Cycle Alarm Holder3
Used by: IP2
Cause: There was a holder 3 cylinder alarm.
Remedy: Adjust the advanced and retracted positions of the holder 3 cylinder.
------------------------------
Code: 12054016
Display: Cycle Alarm Holder4
Used by: IP2
Cause: There was a holder 4 cylinder alarm.
Remedy: Adjust the advanced and retracted positions of the holder 4 cylinder.
------------------------------
Code: 12054017
第 544 页