FUJI错误代码查询.pdf - 第467页
Remedy: Resupply the parts. ------------------------------ Code: 1204010B Display: Recovery limit error! Used by: NP2,QP3 Cause: The recovery limit has been reached. Remedy: Clear the cause of the error and press the RES…
Code: 12040104
Display: Supply components PM??:D**
Used by: CP3,CP5,IP1,IP2,IP3
Cause: No part was picked up. The machine stopped because the tape end sensor detected the end of
the tape or recovery was attempted the number of times specified. D** indicates the device number.
Remedy: Replenish the parts. If there are already parts, check that the machine is picking properly, and
check that the feeder is mounted properly.
------------------------------
Code: 12040105
Display: Supply tray
Used by: IP2
Cause: There is no MTU tray.
Remedy: Replenish the tray.
------------------------------
Code: 12040106
Display: "Empty Check L" (GL), "Empty Check Z1" (FGL5)
Used by: GL2,GL5,GL541
Cause: There is very little glue remaining in each syringe.
Remedy: Add glue, or replace the syringe. If an error occurs, the machine can be started by pressing the
START button but it will stop again after one board has been completed.
------------------------------
Code: 12040107
Display: "Empty Check R" (GL), "Empty Check Z2" (GL5)
Used by: GL2,GL5,GL541
Cause: The amount of glue remaining in syringes is low.
Remedy: Add glue, or replace syringes. The machine will restart operation if the START button is pressed
while this error state is in effect, but it will stop again after applying glue to one board. It is possible to
prevent the machine from checking the amount of glue remaining by adding a value of 1 for the "Machin
status A" parameter in the Proper data.
------------------------------
Code: 12040108
Display: "Empty Check Z3" (GL5)
Used by: GL5,GL541
Cause: The amount of glue remaining in syringes has become low.
Remedy: Add glue, or replace syringes. The machine will restart operation if the START button is pressed
while this error state is in effect, but it will stop again after applying glue to one board. It is possible to
prevent the machine from checking the amount of glue remaining by adding a value of 1 for the "Machin
status A" parameter in the Proper data.
------------------------------
Code: 12040109
Display: Supply Components
Used by: IP1,IP2,NP132,NP133
Cause: All the specified next devices have been used up.
Remedy: Register that the next devices have been replenished. Refer to the appropriate operation manual
for more information about next devices.
------------------------------
Code: 1204010A
Display: NO parts D***
Used by: IP1
Cause: The parts check sensor has detected that there are no parts and the machine has gone out of
automatic operation.
第 466 页
Remedy: Resupply the parts.
------------------------------
Code: 1204010B
Display: Recovery limit error!
Used by: NP2,QP3
Cause: The recovery limit has been reached.
Remedy: Clear the cause of the error and press the RESET button.
------------------------------
Code: 1204010C
Display: Parts error for robot 1!
Used by: NP2,QP3
Cause: A cycle stop was executed due to a parts error.
Remedy: Clear the cause of the error and push the RESET button.
------------------------------
Code: 1204010D
Display: Parts out
Used by: QP301
Cause: No available tray.
Remedy: Supply trays or remove empty trays.
------------------------------
Code: 1204010E
Display: Supplying trays
Used by: QP301
Cause: Supplying trays.
Remedy: Complete tray supply and start Auto Production.
------------------------------
Code: 1204010F
Display: Glue level warning.
Used by: QP3
Cause: Syringe glue exhausted.
Remedy: Resupply glue and resume operation.
------------------------------
Code: 12040110
Display: Glue level warning.
Used by: QP3
Cause: Switching to single panel production due to limited glue. The machine will stop when the next
panel is complete.
Remedy: Resupply glue and resume operation.
------------------------------
Code: 12040111
Display: Glue level warning.
Used by: QP3
Cause: Insufficient remaining glue.
Remedy: Resupply glue and resume operation.
------------------------------
Code: 12040112
Display: Recovery selection not specified.
Used by: QP3
Cause: The head at which the insertion error occurred does not perform move as specified when
production is resumed.
Remedy: After verifying the part status for the insertion error, select [Automatic] qG [Sequence] at the
第 467 页
touch panel to access the sequence screen, and specify whether recovery selection for the head in question
is necessary or not.
------------------------------
Code: 12040113
Display: MTU parts are being supplied.
Used by: QP3
Cause: MTU parts are being supplied.
Remedy: After completion of parts supply, press the [SUPPLY COPLT] button.
------------------------------
Code: 12040114
Display: 料尽。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 到达了设定的补件数。
Remedy: 因料尽而使机器停止时,请在补充元件后在重新开始生产。
有元件的时候,请确认吸取状态是否正确。
另外,请检查供料器或者料盘是否正确地安装。
------------------------------
Code: 12040115
Display: 超出最大补件次数
Used by: XP141
Cause: 到达了设定的补件数。
Remedy: 因料尽而使机器停止时,请按下“料尽确认”按键,请在补充元件后在重新开始生产。
有元件的时候,请确认吸取状态是否正确。
另外,请检查供料器是否正确地安装。
------------------------------
Code: 12040201
Display:
Used by:
Cause: A part was dropped.
Remedy: Re-pick the part.
------------------------------
Code: 12040202
Display: Sub nozzle parts drop
Used by: IP1,IP2
Cause: A part was dropped before being set onto the carrier.
Remedy: Check the air pressure, and check the sub-nozzle part detection sensor.
------------------------------
Code: 12040203
Display: Carrier parts drop
Used by: IP2
Cause: A part was dropped while the carrier was in motion.
Remedy: Process the dropped part.
------------------------------
Code: 12040204
Display: "Part dropped during dipping operation"
Used by:
Cause: A component has been dropped during a dipping operation.
Remedy: If a component was dropped in the flux container, adjust the "Dipping_depth", "Dipping_timer",
or "Slow_dipping_speed" parameters. If this error has occurred even though no component was dropped,
make sure that the vacuum sensor is turning on and off normally.
------------------------------
第 468 页