FUJI错误代码查询.pdf - 第326页

Code: 12031277 Display: Used by: QP242,QP201,QP202,QP203 Cause: Unit number 2 (VM 1440). Communication internal alarm. Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji. -----------------------…

100%1 / 5282
Cause: Unit number 2 (VM 1440). Framing occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031264
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Parity error occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031265
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Over-run error occurred during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031266
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). DCD turned off during reception.
Remedy: Inspect the transmission cable.
------------------------------
Code: 12031272
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031273
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031274
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031275
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031276
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
第 325 页
Code: 12031277
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031278
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031279
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 1203127A
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 1203127B
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 1203127C
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 1203127D
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 1203127E
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 1203127F
Display:
Used by: QP242,QP201,QP202,QP203
第 326 页
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031280
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031288
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031289
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 1203128A
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 1203128B
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 2 (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031300
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 3 (ACIA) parity error.
Remedy: Turn off the machine power.
------------------------------
Code: 12031301
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 3 (ACIA) parity error.
Remedy: Turn off the machine power.
------------------------------
Code: 12031302
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number 3 (ACIA) reception buffer full.
Remedy: Turn off the machine power.
------------------------------
第 327 页