FUJI错误代码查询.pdf - 第498页
Display: A safety relay error occurred. Used by: NP2,QP3 Cause: Safety relay failed to come on within prescribed time. Remedy: Check the safety relay input. ------------------------------ Code: 120501A2 Display: Nozzle l…
Code: 12050195
Display: D2 pallet sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D2 pallet UP sensor. The D2 pallet UP sensor (X0A2) and DOWN
sensor (X095) are both on.
Remedy: Check the sensors.
------------------------------
Code: 12050196
Display: Currently in maintenance mode!
Used by: NP2,QP3
Cause: The part supply unit is currently in maintenance mode.
Remedy: Leave the maintenance mode to start automatic operation.
------------------------------
Code: 12050197
Display: D2 pallet position error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: A logic error occurred at the D2 pallet UP (X0A2) and DOWN (X095) sensors. Both of these
sensors are off.
Remedy: Lower the D2 pallet.
------------------------------
Code: 12050198
Display: D1 pallet position error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: D1 pallet position error.A logic error occurred at the D1 pallet UP (X08C) and DOWN (X07F)
sensors.Both of these sensors are off.
Remedy: Lower the D1 pallet.
------------------------------
Code: 12050199
Display: 温度超范围
Used by: NXTP
Cause: 机内温度超范围。
Remedy: 1)请确认温控单元。2)请确认温度设定是否合理 3)请确认机外温度是否超出下列范围:合理温度度
±5℃。温控单元的温度调节范围为±5度。4)如果温度没有显示,则有可能是控制器出了故障。
<img src="$LKEY_ERRIMG_MC$/12050199.PNG">
------------------------------
Code: 1205019A
Display: 湿度在合适范围外
Used by: NXTP
Cause: 机内湿度在合适范围之外。
Remedy: 1)请调整湿度。
2)请确认湿度设定范围是否合适。
<img src="$LKEY_ERRIMG_MC$/1205019A.PNG">
------------------------------
Code: 1205019B
Display: 清洗剂蓄水盘已满
Used by: NXTP
Cause: 清洗剂蓄水盘已满。
Remedy: 请将被堵塞的清洗剂输送管路打通。
<img src="$LKEY_ERRIMG_MC$/EI0243.png">
------------------------------
Code: 120501A0
第 497 页
Display: A safety relay error occurred.
Used by: NP2,QP3
Cause: Safety relay failed to come on within prescribed time.
Remedy: Check the safety relay input.
------------------------------
Code: 120501A2
Display: Nozzle length error.
Used by: NP2,QP3
Cause: The nozzle is bent, an incorrect nozzle is loaded, the nozzle check sensor is not adjusted correctly
, or the nozzle check position is incorrect.
Remedy: Check the loaded nozzle. If the correct nozzle is loaded, check the nozzle check sensor is
adjusted correctly, or remeasure the nozzle check position.
------------------------------
Code: 120501A3
Display: Nozzle diameter error.
Used by: NP2,QP3
Cause: The nozzle diameter is incorrect.
Remedy: Attach a nozzle with the correct diameter.
------------------------------
Code: 120501B0
Display: 吸件后,吸嘴活塞不能上升。请除去锁定活塞的原因。
Used by: XP141
Cause: 吸嘴活塞有可能锁住。
Remedy: 请试着将吸嘴活塞压住,确认是否能上下顺畅地移动。
------------------------------
Code: 120501B1
Display: 压送后、吸嘴活塞不能上升。请除去锁定活塞的原因。
Used by: XP141
Cause: 吸嘴活塞有可能锁住。
Remedy: 请确认复位气缸上升确认传感器是否正常地动作。
请试着将吸嘴活塞压住,确认是否能上下顺畅地移动。
------------------------------
Code: 120501B2
Display: 复位汽缸动作出错。
Used by: XP141,XP142
Cause: 没有进行复位气缸的上升以及下降的确认。
Remedy: 请确认复位气缸上升确认传感器是否正常地动作。
吸嘴活塞有可能锁住。
请试着将吸嘴活塞压住,确认是否能上下顺畅地移动。
------------------------------
Code: 120501B3
Display: 真空支撑销干扰传感器有反应。
Used by: XP141,XP241,XP341,XP142,XP242,GPX,NXTP
Cause: 真空支撑销干扰传感器被遮住光线。
Remedy: 请修正吸取位置。
请确认真空支撑销干扰传感器的反应是否异常。
<img src="$LKEY_ERRIMG_MC$/120501B3.PNG">
------------------------------
Code: 120501B4
Display: 热量异常。请确认下列项目。
Used by: XP141,XP241,XP341,XP142,XP242
第 498 页
Cause: 检测出热量异常。
Remedy: 请确认X,Y轴再生电阻的温度保险丝、真空泵的温度保险丝(XP141,XP142)、
真空泵用马达的热继电器(XP141,XP142)是否异常。
------------------------------
Code: 120501B5
Display: 废料箱脱离了。
Used by: XP141
Cause: 废料带切刀打开的状态下、废料带箱脱离。
Remedy: 请确认废料带箱是否脱离。
请确认废料带箱有无确认传感器是否正常地动作。
请确认废料带箱是否正常地动作。
------------------------------
Code: 120501B6
Display: 吸取位置超过极限值。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 吸取位置X或Y超过极限值。
Remedy: 请确认吸取补正值以及Pick-up Point Offset。
------------------------------
Code: 120501B7
Display: 吸取位置超过极限值。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 吸取位置Z超过极限值。
Remedy: 请确认Pick-up Point Offset Z。
------------------------------
Code: 120501B8
Display: 在送出料盘动作中料盘掉下来了。
Used by: XP241,XP242
Cause: 在吸取空料盘的状态下移动吸取器时吸取传感器处于OFF。
Remedy: 请清除机器内落下的空料盘。
------------------------------
Code: 120501B9
Display: 吸取的测定位置超过伺服极限位置。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 吸取的测定位置超过伺服极限位置。
Remedy: 请确认固有值的伺服极限值是否设定成正确的数值。
伺服极限值是正确的时候,为了能使吸取位置测定功能可以进行而有必要扩大进行机器改造的伺服极限值。
在没有结束改造的机器上,请将固有值__PickPosAutoMeasure设定为0、并使本功能无效。
------------------------------
Code: 120501BA
Display: 不能使往复臂前进。
前进侧已有料盘托架。
请确认料盘托架位置。
Used by: XP241,XP242
Cause: 因为前进侧有料盘托架(料盘前进确认传感器处于OFF)、所以不能使往复臂移动到前进侧。
Remedy: 请确认料盘托架位置。
请确认料盘前进确认传感器是否正常地动作。
------------------------------
Code: 120501BB
Display: 不能使往复臂后退。
后退侧已有料盘托架。
请确认料盘托架位置。