Remedy: Check that there is no load on the cylinder. Also check the sensor signal at the I/O map. ------------------------------ Code: 15024003 Display: (Differs according to the machine.) Failed to arrive at target posi…

100%1 / 5282
------------------------------
Code: 15021005
Display: Loader ROM Error.
Used by:
Cause: The software version in the board loader PLC ROM is newer than the software version in the
machine ROM. An error results when the PLC version is higher than the machine version.
Remedy: Contact Fuji.
------------------------------
Code: 15021006
Display: not in loading pos.
Used by: GSP5,GP2,GP551,GP3,GP6
Cause: The table was not in loading position when the lock/unlock function was attempted in order to
perform conveyor width adjustment.
Remedy: Perform the load position command to move the table to the loading position.
------------------------------
Code: 15021007
Display: Board pstn alarm main cnvyr
Used by: GSP5,GP551,GP6
Cause: The main conveyor board check is unclear, so the results of the check are that there is a board on
the main conveyor.
Remedy: Unload this board to the out conveyor.
------------------------------
Code: 15021008
Display: unrecognizable command
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: Either there is no Proper data measurement or zero setting was not performed.
Remedy: If there is no Proper data, transmit Proper to the machine. Then, perform zero setting.
------------------------------
Code: 15021009
Display: interlock
Used by: GSP5,GP551,GP6
Cause: The width adjustment clutch has not been released so the table cannot be moved.
Remedy: Remove the clutch using the loader unlock command. If the problem recurs, adjust the clutch
retract limit sensor.
------------------------------
Code: 1502100B
Display: Idle operation error!
Used by: NP2,QP3
Cause: The loader contains a PCB, even though the machine is in idle operation.
Remedy: Remove the PCB from the loader.
------------------------------
Code: 15024001
Display: Cycle alarm servo ??
Used by:
Cause: The servo did not reach its target position within the preset time limit.
Remedy: Check that there is no load on the servo axis.
------------------------------
Code: 15024002
Display: Cycle aiarm ??
Used by:
Cause: The cylinder did not reach its target position within the preset time limit.
第 1103 页
Remedy: Check that there is no load on the cylinder. Also check the sensor signal at the I/O map.
------------------------------
Code: 15024003
Display: (Differs according to the machine.)
Failed to arrive at target position.(NP2,QP3)
Used by:
Cause: Board delivery time up error.
The specified time for the monitoring of the clearance of the PCB request signal has
elapsed.(NP2,QP3)
Remedy: The board stalled on the conveyor. Remove the board from the conveyor or re-load the board.
------------------------------
Code: 15024004
Display: (Differs according to the machine.)
Used by:
Cause: The lifter did not reach its target position within the preset time limit.
Remedy: The lifter is not working. At the I/O map check the lifter operation and the sensor input.
------------------------------
Code: 15024005
Display: (Differs according to the machine.)
Used by:
Cause: The sequencer did not reply within the preset time.
Remedy: There is no reply from the loader's sequencer. Switch off the machine and then re-boot it. If the
problem recurs it is probably due to a wiring fault or damage to the sequencer.
------------------------------
Code: 15024006
Display: (Differs according to the machine.)
Used by:
Cause: The reference pin did not reach its target position within the preset time limit.
Remedy: The reference pin is not moving. At the I/O map check the reference pin and the sensor input.
------------------------------
Code: 15024007
Display: (Differs according to the machine.)
Used by: IP3
Cause: Vertical movement of the 2 level conveyor could not be completed within the preset time limit.
Remedy: The 2 level conveyor could not move up or down within the set time. Check that it is possible for
the 2 level conveyor to freely move up and down.
------------------------------
Code: 15024008
Display: Cycle alarm (cylinder) conveyor adj. clutch
Used by: GSP5,GP551,GP6
Cause: The clutch could not enter the conveyor connecting notch within the preset time limit.
Remedy: Check for items that may be interfering with clutch movement. Check the widths of the main
and out conveyors to make sure they match. Check the sensors at the I/O board.
------------------------------
Code: 15024009
Display: Cycle alarm (cylinder) backup pin
Used by: GSP5,GP551,GP6
Cause: The backup pin could not lock or unlock within the preset time limit.
Remedy: Check the sensors at the I/O board.
------------------------------
Code: 1502400A
第 1104 页
Display: Package unclamping error!
Used by: QP301
Cause: The ON or OFF signal for the package unclamper timed out.
Remedy: Check for interference with the package unclamper.
------------------------------
Code: 15026007
Display: Package unclamper sensor error!
Used by: QP301
Cause: Both the ON and OFF sensor of the package unclamper are on.
Remedy: Check both sensors.
------------------------------
Code: 15031001
Display:
Used by: CP5,GL5,GL541,IP3
Cause: Operation was cancelled because of an alarm from the application.
Remedy: None.
------------------------------
Code: 15031002
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: Loading position alarm.
Remedy: None.
------------------------------
Code: 15031003
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: Lifter position error
Remedy: None.
------------------------------
Code: 15031004
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,CP-752,GL5,GL541,IP3
Cause: Interlock error
Remedy: None.
------------------------------
Code: 15031005
Display: Loader ROM Error
Used by:
Cause: The board loader PLC ROM version is newer than the machine ROM version (i.e. the number of
the machine version is lower than the number of the PLC version).
Remedy: Contact Fuji.
------------------------------
Code: 15031006
Display: Brd supply number rpt error
Used by: CP643
Cause: Board quantity cannot be ascertained when loading a board from in-carrier to main conveyor.
Remedy: Turn the machine off,then on again.
------------------------------
Code: 15031007
Display: IN-loader brd rpt error
Used by: CP643
第 1105 页