FUJI错误代码查询.pdf - 第823页

Remedy: Check whether the RS cable to the MTU6 is disconnected. ------------------------------ Code: 1207E?31 Display: "SCU?(ICM,PMC?) Error Code:********" (QP2) "RS Port Not Set / Flux" (QP2) Used by…

100%1 / 5282
select station upper and lower limit sensors are functioning normally.
------------------------------
Code: 1207E?2B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TY Not in Safe Vertcl Pos." (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The TZ-axis cannot be moved because the TY-axis is not in a position that allows vertical
movement.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to return the TY-axis to a position (i.e., the forward or retract
end) that will allow the TZ-axis to be moved.
------------------------------
Code: 1207E?2C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TY Not at Forward End" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The TZ-axis cannot be moved because the TY-axis is not at the forward end.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to move the TY axis to the forward end.
------------------------------
Code: 1207E?2D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TZ Incorrect Stop Pos." (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The TY-axis cannot be moved because the TZ-axis is not stopped at the correct position.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to return the TZ-axis to a position that will allow the TY-axis to
be moved.
------------------------------
Code: 1207E?2E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Mag.slot Occupied w/ Tray" (QP2)
Used by: QP242
Cause: A tray cannot be stored in the magazine tray slot because the slot is already occupied by a tray.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the tray from the magazine, and store it at another device position in the magazine.
------------------------------
Code: 1207E?2F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"RS Port Not Set / MTU6" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The MTU6 cannot be started because the RS port has not been set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?30
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"RS Cable Not Conected/MTU6" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The MTU6 cannot be started because the RS cable is not connected.
(value replacing "?" is module number; error code appears in place of asterisks)
第 822 页
Remedy: Check whether the RS cable to the MTU6 is disconnected.
------------------------------
Code: 1207E?31
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"RS Port Not Set / Flux" (QP2)
Used by: QP242
Cause: The flux application pump cannot be started because the RS port has not been set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?32
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"RS Cable Not Connected/Flux" (QP2)
Used by: QP242
Cause: The flux application pump cannot be started because the RS cable is not connected.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?33
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Inexcutable (FZ not up-end)" (QP2)
Used by: QP242
Cause: The command cannot be executed because the flux application axis (FZ-axis) is not at the upper
limit.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use an I/O command or other method to raise the flux head.
------------------------------
Code: 1207E?34
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Pstn'g time-out (FX/TY/TZ)" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Positioning timeout (FX-axis, TY-axis, or TZ-axis).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the above-named axes, or whether the axis action
has become extremely heavy. Check the robust controller for problems.
------------------------------
Code: 1207E?35
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"FZ-axis operation time-out" (QP2)
Used by: QP242
Cause: Timeout during FZ-axis operation.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the FZ-axis. Make sure that the upper and lower
limit sensors are functioning normally.
------------------------------
Code: 1207E?36
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Syringe size parameter 0" (QP2)
Used by: QP242
Cause: The parameter that specifies the flux syringe size is set to 0.
(value replacing "?" is module number; error code appears in place of asterisks)
第 823 页
Remedy: Set the flux ejection quantity in the "Flux Cylinge Size" parameter in the Proper data.
------------------------------
Code: 1207E?37
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"SCU warning" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: SCU warning report.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?38
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC communication timeout" (QP2)
Used by: QP242
Cause: A timeout has occurred during communication with the PPC.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether the cable to the PPC is connected. Check the PPC for problems.
------------------------------
Code: 1207E?39
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Data overflow at PPC" (QP2)
Used by: QP242
Cause: PPC data overflow.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the power off and on once, then perform measurements again. Make sure the cable
between the PPC and the load cell table is not broken.
------------------------------
Code: 1207E?3A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC measurement unstable" (QP2)
Used by: QP242
Cause: PPC measurement values are not stable.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the power off and on once, then perform measurements again. If this error occurs
frequently, the PPC must be replaced.
------------------------------
Code: 1207E?3B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC Holdmode not set" (QP2)
Used by: QP242
Cause: The PPC hold mode has not been set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Change the PPC hold mode setting to 3.
------------------------------
Code: 1207E?3C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC Zero-tracking mode..." (QP2)
Used by: QP242
Cause: The PPC is operating in zero-tracking mode.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the PPC zero-tracking function off.
第 824 页