FUJI错误代码查询.pdf - 第475页

Remedy: Resupply parts to the feeder at the target slot. ------------------------------ Code: 12040602 Display: Splicing warning (remaining parts). Used by: Cause: The number of parts remaining has reached the splicing l…

100%1 / 5282
------------------------------
Code: 12040505
Display: Part detected returning to feeder
Used by: QP3
Cause: A part was detected returning to the feeder and vision processing
was preformed but the part was not confirmed.
The pressure sensor may have output an incorrect signal.
If production is continued a placement may be duplicated.
Check the following before proceeding.
Remedy: Check if the sequence displayed in the parameters has been
placed on the panel.
If the part has been placed, an incorrect signal was received.
If this is the case, skip the sequence at the [Start] screen.
Furthermore, the sensor may be damaged, please contact your Fuji
representative.
If the part has not been placed, a vision processing error has
occurred due to a discharge or the part fell during movement.
Check the part has not fallen in the machine and that it is not
on the panel or camera. This may cause damage to the machine.
------------------------------
Code: 12040506
Display: Fix Flux Unit Error
Used by: QP3
Cause: Fix flux unit does not function correctly or the unit's status(set/not set) setting is incorrect.
Remedy: When the fix flux unit is mounted on the machine: Check that there
is no obstruction in an operating area of the unit.
When the fix flux unit is not mounted on the machine: Set the data (Fix Flux Sw) to "0" to set the
unit's status to "not set".
------------------------------
Code: 12040507
Display: Placement Revision Limit
Used by: NP133,NP134,NP153
Cause: The X-direction amount from the results of offset calculations preformed during placement
exceeds the value set for "Placement Revision X".
Remedy: Confirm that the specified value is not too small.
When contacting Fuji, ensure to attach trace data taken immediately after error occurred.
------------------------------
Code: 12040508
Display: Placement Revision Limit
Used by: NP133,NP134,NP153
Cause: The Y-direction amount from the results of offset calculations preformed during placement
exceeds the value set for "Placement Revision Y".
Remedy: Confirm that the specified value is not too small.
When contacting Fuji, ensure to attach trace data taken immediately after error occurred.
------------------------------
Code: 12040601
Display: Parts out limit (remaining parts).
Used by:
Cause: The number of parts remaining has reached the low quantity limit.
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or at the Handy Terminal.
第 474 页
Remedy: Resupply parts to the feeder at the target slot.
------------------------------
Code: 12040602
Display: Splicing warning (remaining parts).
Used by:
Cause: The number of parts remaining has reached the splicing low quantity limit.
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or at the Handy Terminal.
Remedy: Splice new parts to the feeder at the target slot.
------------------------------
Code: 12040603
Display: Parts out warning (remaining time).
Used by:
Cause: The number of parts remaining has reached the low quantity limit (time).
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or using the parts administration functions at the machine.
Remedy: Resupply parts to the feeder at the target slot, or prepare parts for resupply.
------------------------------
Code: 12040604
Display: Splicing limit.
Used by:
Cause: The number of parts remaining has reached the splicing limit.
This error is also a warning for faulty splicing.
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or at the Handy Terminal.
Remedy: Carry out verification again for the parts on the feeder at the target slot.
------------------------------
Code: 12040605
Display: Verification incomplete.
Used by:
Cause: The machine attempted to pick-up a part for which verification is not complete.
Verification has not been properly completed.
Communications with Fujitrax Verifier may be in progress.
The parameter indicates the target slot number.
Remedy: Carry out verification using the Handy Terminal.
If communications with Fujitrax Verifier are still in progress,
complete the communications at the device check screen,
and continue production when verification is complete.
------------------------------
Code: 12040606
Display: Device check incomplete
Used by:
Cause: Production cannot commence because the device check has not been completed.
Remedy: Perform verification for any incomplete devices using the device check panel.
------------------------------
Code: 12040632
Display: Duplicate FIDL
Used by:
Cause: An FIDL for a feeder that is already registered for another feeder on the machine has been
submitted.
An FIDL for a feeder loaded on the machine has been duplicated.
第 475 页
Fujitrax Verifier will not be able to administer parts correctly.
The parameter indicates the target slot number.
Remedy: Use a feeder with a different FIDL, or make a new FIDL for the feeder with the duplicated FIDL.
------------------------------
Code: 12040633
Display: Duplicate DID
Used by:
Cause: A DID for a part that is already registered for another part on the machine, has been submitted.
A reel DID loaded on the machine has been duplicated.
Fujitrax Verifier will not be able to administer parts correctly.
The parameter indicates the target slot number.
Remedy: Make a new DID for the parts reel that has the duplicated DID.
------------------------------
Code: 12040634
Display: Statistical device error
Used by:
Cause: The specified error count was reached when performing statistical device skip processing.
The machine was stopped due to a statistical device error.
Remedy: Adjust the feeder or nozzle used for the slot at which the statistical device skip error was issued.
------------------------------
Code: 12040635
Display: Statistical device warning
Used by:
Cause: The specified error count was reached when performing statistical device skip processing.
Remedy: Adjust the feeder or nozzle.
------------------------------
Code: 12042001
Display: "CARTRIDGE NG" (CP), Feeder NG" (CP5), or "FEEDER SET *" (IP2)
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,IP2,IP3
Cause: This is a tape leaf error (an error in the tape feeder error). The tape leaf detection sensor has
been tripped.
Remedy: Check the feeder. Make sure the feeder is properly set on the pallet. Check the tape leaf
detection sensor.
------------------------------
Code: 12042002
Display: "CARTRIDGE NG" (CP), Feeder NG" (CP5), or "FEEDER SET *" (IP2)
Tape leaf sensor error!(NP2,QP3)
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,IP2,IP3,NP2,QP3
Cause: This is a tape leaf error (an error in the tape feeder error). The tape leaf detection sensor has
been tripped.
The tape leaf sensor was triggered.(NP2,QP3)
Remedy: Check the feeder. Make sure the feeder is properly set on the pallet. Check the tape leaf
detection sensor.
Check the condition of the feeders.(NP2,QP3)
------------------------------
Code: 12042003
Display: COMP. UNSET
Used by: CP3
Cause: The parts have not been set (CP3).
Remedy: Set the parts.
------------------------------
第 476 页