FUJI错误代码查询.pdf - 第483页
The parameter indicates the target slot number. Remedy: Carry out a device check at the device check screen. Check that the splicing detection sensor is operating correctly. ------------------------------ Code: 1204B000 …
Remedy: Prepare the reject parts conveyor. If parts can be rejected to positions other than the conveyor,
change the [Reject Position] in part data to a position other than the conveyor.
------------------------------
Code: 1204A300
Display: Coplanarity Err
Used by: IP1,IP2,IP3
Cause: The results of coplanarity calculations indicate that the height of at least one lead exceeds the set
tolerance (Coplanarity item 2.Coplanarity_tolerance).
Remedy: Check whether the leads are coplanar. Check that the value set in 2.Coplanarity_tolerance is
not too small.
------------------------------
Code: 1204A301
Display: Linearity Err
Used by: IP1,IP2,IP3
Cause: The measurement indicates that the height of at least one lead exceeds the set tolerance
(Coplanarity item 3.Linearity_tolerance).
Remedy: Check whether the lead linearity is within set limits. Check that the value set in
3.Linearity_tolerance is not too small.
------------------------------
Code: 1204A302
Display: Lead qty Err
Used by: IP1,IP2,IP3
Cause: The measurement indicates that the number of leads on the part are not the same as the Qty in
Part data.
Remedy: Check that some leads are not bent. Confirm that the number input in Vision datals
10.lead_length,11.Lead_length_y, and in Side data's Body_size and Qty are correct.
------------------------------
Code: 1204A303
Display: Scan pos Err
Used by: IP1,IP2,IP3
Cause: Coplanarity check cannot be done because the point at which the part was picked was too close
to the leads (i.e., if the check was performed the nozzle might hit the sensor).
Remedy: Check that the part size and lead length are appropriate. Check that the part picking position is
not at the corner of the part.
------------------------------
Code: 1204A401
Display: No response from the splicing detection sensor.
Used by:
Cause: There was no response from the splicing detection sensor, even though a splicing report was
submitted from the Handy Terminal.
The splicing clip may have dropped off, or the splicing detection sensor may be out of order.
The parameter indicates the target slot number.
Remedy: Check that the splicing detection sensor is operating correctly, and that the splicing clip has not
dropped off the tape.
------------------------------
Code: 1204A402
Display: No splicing report.
Used by:
Cause: Splicing has been detected, but no splicing report has been received for that slot.
No splicing report was submitted from the Handy Terminal, or the splicing detection sensor may be
out of order.
第 482 页
The parameter indicates the target slot number.
Remedy: Carry out a device check at the device check screen.
Check that the splicing detection sensor is operating correctly.
------------------------------
Code: 1204B000
Display: “毛巾余量不足 上”/“毛巾余量不足 下”
Used by: GSP5,GP551,GP6,GPX,NXTP
Cause: 上或下的毛巾余量计数器到了设定值。或者,由传感器测出。
Remedy: 请供应毛巾。
<img src="$LKEY_ERRIMG_MC$/1204B000.PNG">
------------------------------
Code: 1204B001
Display: 溶剂的余量不足了
Used by: GSP5,GP551,GP6,GPX.NXTP
Cause: 没有清洁用的溶剂。
Remedy: 请添加溶剂。
<img src="$LKEY_ERRIMG_MC$/1204B001.PNG">
------------------------------
Code: 1204B002
Display: Solder Supply Remaining Level Warning
Used by: GP551,GP6,NXTP
Cause: The solder has run out.
Remedy: Supply solder.
<img src="$LKEY_ERRIMG_MC$/1204B002.PNG">
------------------------------
Code: 1204B003
Display: Backlight brightness deficiency.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The backlight brightness for the nozzle(s) indicated at the Parameter area is insufficient. When
several nozzles are involved, the nozzle backlight disks may be soiled.
Remedy: Replace the nozzle(s). If this error occurs frequently, there may be an ultraviolet lamp problem.
In this case, replace the light source.
------------------------------
Code: 1204B005
Display: 清洁纸剩余量警告
Used by: NXTP
Cause: 超过了清洁纸的剩余量。
Remedy: 请进行供应清洁纸的准备。
<img src="$LKEY_ERRIMG_MC$/1204B005.PNG">
------------------------------
Code: 1204B006
Display: 锡膏余量不足
Used by: NXTP, GPX-C
Cause: 锡膏自动供应器内的锡膏即将用完。
Remedy: 请准备新锡膏。
<img src="$LKEY_ERRIMG_MC$/1204B006.png">
------------------------------
Code: 1204B007
Display: 焊锡杯托架脱落
Used by: NXTP,GPX-C
Cause: 焊锡杯托架没有正确地安装在机器上。
第 483 页
Remedy: (NXTP)
●[Detect cup holder]为[Yes]时
1.请将焊锡杯托架安装到机器上
2.可能是托架安装监视传感器[X10C]发生故障
●[Detect cup holder]为[No]时
1.请将安装有焊锡杯的焊锡杯托架安装到机器上
2.可能是焊锡余量传感器[X109]发生故障
(GPX-C)
没有成为负压。
1.请将焊锡杯托架安装到机器上
2.可能是减压机构[IN35,OUT33]发生故障
<img src="$LKEY_ERRIMG_MC$/1204B007.png">
------------------------------
Code: 1204B008
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1204C0??
Display: Same as Code
Used by: QP132
Cause: This is the code used by production data indicating that the recovery limit was reached. The code
includes device numbers and so the number of times that recovery has been carried out can be
determined when the system creates a production data summary. The vision processing error code that
was the direct cause of the recovery processing is recorded in a different report.
The "??" represent the device number.
Remedy: This code represents the recovery code. Carry out the necessary adjustments in light of the
vision processing error which caused the recovery processing.
------------------------------
Code: 1204C1??
Display: Same as Code
Used by: QP132
Cause: This is the code used by production data indicating that the recovery limit was reached. The code
includes device numbers and so the number of times that recovery has been carried out can be
determined when the system creates a production data summary. The vision processing error code that
was the direct cause of the recovery processing is recorded in a different report.
The "??" (+255) represent the device number.
Remedy: This code represents the recovery code. Carry out the necessary adjustments in light of the
vision processing error which caused the recovery processing.
------------------------------
Code: 12050001
Display: 操作系统错误
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 操作系统错误
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据并送至弊社。
------------------------------
Code: 12050002
Display: 操作系统错误
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 操作系统错误
第 484 页