Cause: The scan area is too narrow. Remedy: The minimum scan area is 0.2 millimeters. Make sure that the mark data description in the production program is correct. ------------------------------ Code: 1CB04003 Display: …

100%1 / 5282
------------------------------
Code: 1CB03004
Display:
Used by: GL541
Cause: Mark data registration failed.
Remedy: Check that the settings in the production program are correct.
------------------------------
Code: 1CB03010
Display: 1CB03010
Used by: GL541,QP132
Cause: The mark could not be found.
Remedy: Check that the production program's mark data is correct. Check that the coordinates of the
mark in the production program are correct.
------------------------------
Code: 1CB03011
Display: 1CB03011
Used by: GL541
Cause: The scan area is too narrow.
Remedy: Set the production program scan area to 1.5 times the mark size. However, the maximum scan
area is 8 mm.
------------------------------
Code: 1CB03012
Display:
Used by: GL541
Cause: There is a large difference between the actual mark size and that in Mark Data.
Remedy: Change the mark size in Mark data.
------------------------------
Code: 1CB03013
Display: 1CB03013
Used by: GL541
Cause: The shape of the mark is ill defined.
Remedy: Unless the mark shape is clearly defined, production cannot begin. Check that there is no dirt
or foreign objects on the mark itself or in the restricted area around the mark.
------------------------------
Code: 1CB03014
Display: 1CB03014
Used by: GL541
Cause: The mark could not be found.
Remedy: Check that the mark is clearly displayed in the image. If the contrast is not clear, adjust the
gain offset for the mark camera.
------------------------------
Code: 1CB04001
Display: 1CB04001
Used by: GL541
Cause: The scan area is larger than the image.
Remedy: The maximum scan area is 8.0 millimeters. Make sure that the mark data description in the
production program is correct.
------------------------------
Code: 1CB04002
Display: 1CB04002
Used by: GL541
第 1205 页
Cause: The scan area is too narrow.
Remedy: The minimum scan area is 0.2 millimeters. Make sure that the mark data description in the
production program is correct.
------------------------------
Code: 1CB04003
Display: 1CB04003
Used by: GL541
Cause: The glue could not be found.
Remedy: The minimum glue size is 0.008 square millimeters. Verify that the glue does exist in the scan
area. Make sure the mark data glue color in the production program is correct. Verify that the glue is
clearly reflected in the image. Adjust the gain and/or offset of the mark camera if the contrast is not
easily discernible.
------------------------------
Code: 1CB04004
Display: 1CB04004
Used by: GL541
Cause: The glue lies outside of the scan area.
Remedy: Make sure the glue dot is not too big in relation to the scan area due to stringing or excessive
dispensing force. Make sure the scan area is not too narrow in relation to the glue. Also check the mark
data description in the production program for any mistakes.
------------------------------
Code: 1CB05001
Display: 1CB05001
Used by: NP133
Cause: The entered range is larger than the image range.
Remedy: Check the entered range.
------------------------------
Code: 1CB05002
Display: 1CB05002
Used by: NP133
Cause: The calculated average is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB05003
Display: 1CB05003
Used by: NP133
Cause: The calculated standard deviation is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB06001
Display: 1CB06001
Used by: NP133
Cause: The entered parameter is outside the permissible range.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB06002
Display: 1CB06002
Used by: NP133
Cause: The nozzle cannot be detected because of a lack of contrast.
Remedy: Because of a lack of contrast, the vision system cannot determine between the nozzle and the
nozzle disk. Check for deterioration in the nozzle disk sticker and the light source.
第 1206 页
------------------------------
Code: 1CB06003
Display: 1CB06003
Used by: NP133
Cause: The vision window used to calculate the histogram is larger than the image range.
Remedy: Check whether the entered diameter for the nozzle reflective disk is larger than the image range.
Check that there are no marks on the reflective surface which could be mistaken for the nozzle.
------------------------------
Code: 1CB06004
Display: 1CB06004
Used by: NP133
Cause: The calculated average is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB06005
Display: 1CB06005
Used by: NP133
Cause: The calculated standard deviation is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB07001
Display: 1CB07001
Used by:
Cause: Data required for processing has not been entered.
Remedy: Specify the mark size, camera resolution, and window size.
------------------------------
Code: 1CB07002
Display: 1CB07002
Used by:
Cause: Mark is too large.
Remedy: Specify the setting so that mark fits in the window.
------------------------------
Code: 1CB07003
Display: 1CB07003
Used by:
Cause: Window area (range) is incorrect.
Remedy: Specify the window range so that the window fits in the screen.
------------------------------
Code: 1CB07004
Display: 1CB07004
Used by:
Cause: No image contrast.
Remedy: Check to see if the image is being acquired properly. Also verify that the nozzle is correct.
------------------------------
Code: 1CB07005
Display: 1CB07005
Used by:
Cause: No mark at the specified position.
Remedy: Check to see if the wrong position was specified.
------------------------------
Code: 1CB07006