Display: "Pallet clamp error: IN stn" Used by: CP5 Cause: The carrier pallet check sensor has not turned on even though the machine's pallet status memory data indicates that there is a pallet in the IN st…
Display: 操作系统错误
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 操作系统错误
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据并送至弊社。
------------------------------
Code: 12050030
Display: 伺服系统错误。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 伺服系统错误
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据并送至弊社。
------------------------------
Code: 12050031
Display: 伺服系统错误。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 伺服系统错误
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据并送至弊社。
------------------------------
Code: 12050032
Display: 伺服系统错误。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 伺服系统错误
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据并送至弊社。
------------------------------
Code: 12050033
Display: 未获取绝对值数据。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 未获取绝对值数据。有可能是与伺服相关的硬件的故障。
Remedy: 有可能是与伺服相关的硬件的故障。如果发生的话,请获取跟踪数据并送至弊社。
------------------------------
Code: 12050101
Display: 安全门不良 (GL,IP2) 或者防护栏 ? FENCE ?(CP) FENCE 1,2(CP3)
F,R FENCE(CP3) R DOOR(CP3)
安全门敞开(NP2,QP3)
Used by: CP3,CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,GP551,GP6,IP1,IP3,
QP242,QP201,QP202,QP203,QP132,NP132,NP133,NP2,QP3,CP-732E,CP-742ME,CP-742E,CP-
752E,GPX,NXTP
Cause: 门、防护栏敞开了。FENCE 1,2: 后面右、左面的光防护栏, F FENCE:前面的门, R FENCE:后面中央的防
护栏, R DOOR:后面的门
安全门敞开了。(NP2,QP3) 安全门打开着。(GPX)
Remedy: 请关闭门、防护栏。
请关闭参数部所显示的平台的安全门,按下READY ON 。(NP2,QP3) 请关闭安全门。(GPX)
<img src="$LKEY_ERRIMG_MC$/12050101.PNG">
------------------------------
Code: 12050102
Display: SHUTTER ?
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The shutter is down (CP).
Remedy: Raise the shutter.
------------------------------
Code: 12050104
第 490 页
Display: "Pallet clamp error: IN stn"
Used by: CP5
Cause: The carrier pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the IN station.
Remedy: If there is a pallet in the IN station, check the carrier pallet check sensor. If there is no pallet,
enter a command to set the IN station ID to 0.
------------------------------
Code: 12050105
Display: "Pallet clamp error: WRK stn"
Used by: CP5
Cause: The carrier pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the WRK station.
Remedy: If there is a pallet in the WRK station, check the carrier pallet check sensor. If there is no pallet,
enter a command to set the WRK station ID to 0.
------------------------------
Code: 12050106
Display: "Pallet clamp error: OUT stn"
Used by: CP5
Cause: The carrier pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the OUT station.
Remedy: If there is a pallet in the OUT station, check the carrier pallet check sensor. If there is no pallet,
enter a command to set the OUT station ID to 0.
------------------------------
Code: 12050107
Display: "Pallet clamp error: IN stn"
Used by: CP5
Cause: The IN station pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the IN station.
Remedy: Check the IN station pallet check sensor.
------------------------------
Code: 12050108
Display: "Pallet clamp error: OUT stn"
Used by: CP5
Cause: The OUT station pallet check sensor has not turned on even though the machine's pallet status
memory data indicates that there is a pallet in the OUT station.
Remedy: Check the OUT station pallet check sensor.
------------------------------
Code: 12050109
Display: "1st pickup check sensor alarm"
Used by: CP5
Cause: The 1st robot component check sensor is stuck off.
Remedy: The 1st robot component check sensor is a reflection sensor. The will not turn on because the
sensor beam is improperly aligned.Adjust the sensor.
------------------------------
Code: 1205010A
Display: Lifter Not at lower limit (CP6/6M).
Used by: CP6
Cause: Before the XY table was moved in the automatic operation mode, the input from the table's lower
position 2 sensor (X032: TABLE DNCHK2) was checked, and found to be OFF. Therefore, to avoid a
collision, an emergency stop was made.
Remedy: Ensure that the sensor at table lower position 2 is working properly. Check for foreign objects on
第 491 页
the table.Move the table to the loading position and ensure that the upper and lower sensors work
properly by performing the lifter up/down command and performing an I/O check.
------------------------------
Code: 1205010B
Display: "Interlock: camera" (GP-6)
Used by: GP551,GP6
Cause: The Z-axis and X-axis are in the interference zone, or are interfering with each other. This error
may also be caused by a sensor error.
Remedy: If the Z-axis and Y-axis are interfering with each other, manually move the X-axis until the X-
axis escape position check sensor (X03D: X ESC POS CHK) is tripped. If they are in the interference zone,
or if there is no interference, check the X-axis escape position check sensor (X03D: X ESC POS CHK) and
the Z-axis camera interference prevention check sensor (X03C: Z ESC POS CHK).
------------------------------
Code: 1205010C
Display: Interlock Sqg/Cleaner Head
Used by:
Cause: This error occurs when both the upper cleaning head and the squeegee are in the lowered
position.
Remedy: Raise the cleaning head or the squeegee holder. Alternatively, check the following sensors:
(X070: (F) SQG HLDR UP, X078: R SQG HLDR UP) or (X07C: TP CLR OPN CHK, X05A: LW CLR OPN CHK).
------------------------------
Code: 1205010E
Display: Sqg Head Unlock
Used by: GP551,GP6
Cause: The squeegee head has been opened.
Remedy: Close and lock the squeegee head.
------------------------------
Code: 1205010F
Display: "Parking Position Error"
Used by: GP551,GP6
Cause: When a parking command is executed, the squeegee head is down after the S-axis has moved to
the position specified in the Proper data and the squeegee parking position check sensor (X03F) has
turned on. This error occurs when the squeegee parking position check sensor remains off after the S-axis
has moved.
Remedy: Check the position detected by the parking position check sensor and the position specified by
the "Parking Position S" parameter in the Proper data.These should be adjusted so that the sensor turns
on when the S-axis arrives at the parking position, and the squeegee head comes to rest on the screen
support when it is down.
------------------------------
Code: 12050110
Display: Sqg Head Position Error
Used by: GP551
Cause: The squeegee head is not in the locked position.
Remedy: Ensure that the squeegee head is in the locked position.
------------------------------
Code: 12050111
Display: Top Cleaner Position Error
Used by: GP551
Cause: The top cleaner swing bar is not in the locked position.
Remedy: Move the top cleaner swing bar to the locked position.
------------------------------