another device. (??? indicates the sequence number (in hexadecimal).) (For sequences above 4096, 4096 is displayed.) Remedy: Check and correct the data item combination D_data TU and D_data TM in the production program. …

100%1 / 5282
(2) 没有解决时,请重新接通电源。
(3) 上述的对策也不能解决时,对不起麻烦您获取错误发生时的跟踪数据,记录下Flexa的设定,与弊公司Support联系
------------------------------
Code: 11C00???
Display: 11C00???
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A device number specified in the placing sequence data is incorrect (out of range).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
For sequences above 4096, 4096 is displayed.
Remedy: Specify the correct data for D in the production program's N_data.
------------------------------
Code: 11C01???
Display: 11C01???
Used by:
Cause: An attempt was made to use device numbers 1 - 3 (85 - 87) even though the MTU1 (MTU2) was
specified.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for D in the production program's N_data for sequences other than 1 -3 and
85 - 87.
------------------------------
Code: 11C02???
Display: 11C02???
Used by:
Cause: There is a mistake in the TPU's original device setting for a particular device.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for OD in the production program's D_data.
------------------------------
Code: 11C03???
Display: 11C03???
Used by:
Cause: There is a mistake in the TPU's unit number setting for a particular device.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for TU in the production program's D_data.
------------------------------
Code: 11C04???
Display: 11C04???
Used by:
Cause: There is a mistake in the TPU's magazine number setting for a particular device.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for TM in the production program's D_data.
------------------------------
Code: 11C05???
Display: 11C05???
Used by:
Cause: This combination of TPU unit number and magazine number has already been specified for
第 274 页
another device.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Check and correct the data item combination D_data TU and D_data TM in the production
program.
------------------------------
Code: 11C06???
Display: 11C06???
Used by: QP132
Cause: There is an unspecified next device in the next device loop.
??? indicates the sequence number (in hexadecimal).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Check the next device loop of the appropriate sequence in the production program. Specify the
next device in Next.
------------------------------
Code: 11C07???
Display: 11C07???
Used by: QP132
Cause: The next device station number is different from the first device.
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for Next in the production program's D_data.
------------------------------
Code: 11C08???
Display: 11C08???
Used by: QP132
Cause: The loop does not close even though the next device nest has exceeded 30 (12 for the QP132).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Check the next device loop of the appropriate sequence. Change Next in D_data so that the loop
closes within 30 devices (within 12 for the QP132).
------------------------------
Code: 11C0A???
Display: Same as Code.
Used by: QP132
Cause: The device comment of the device used by the specified sequence, is not set. This setting must be
made for the QP132.
("???" represents the sequence number in hexadecimal format. However, if the sequence number is 4096
or greater, subtract 4096.)
Remedy: Set the device comment.
------------------------------
Code: 11C10???
Display: 11C10???
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An x coordinate in sequence data is out of range in the minus direction (for example placing area
or movement range).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for X in the production program's N_data.
------------------------------
第 275 页
Code: 11C11???
Display: 11C11???
Used by: QP242,QP201,QP202,QP203,QP132
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Cause: An x coordinate in sequence data is out of range in the plus direction (for example placing area or
movement range).
Remedy: Specify correct data for X in the production program's N_data.
------------------------------
Code: 11C12???
Display: 11C12???
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An y coordinate in sequence data is out of range in the minus direction (for example placing area
or movement range).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for Y in the production program's N_data.
------------------------------
Code: 11C13???
Display: 11C13???
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An y coordinate in sequence data is out of range in the plus direction (for example placing area or
movement range).
(??? indicates the sequence number (in hexadecimal).)
(For sequences above 4096, 4096 is displayed.)
Remedy: Specify correct data for Y in the production program's N_data.
------------------------------
Code: 11C20???
Display: 11C20???
??? represents the sequence number (in hexadecimal).
For sequences above 4096, 4096 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: The main mark or the submark which is referred to by this sequence is not in the production
program, or has been skipped.
Remedy: Check the mark numbers at the placement sequence in question and the main and submark
numbers at the mark sequences.
------------------------------
Code: 11C21???
Display: 11C21???
??? represents the sequence number (in hexadecimal).
For sequences above 4096, 4096 is displayed.
Used by: QP242,IP3
Cause: The referenced main and sub marks for the sequence in question are set to the same number.
Remedy: Check the main and sub mark numbers.
------------------------------
Code: 11C22???
Display: 11C22???
??? represents the sequence number (in hexadecimal).
For sequences above 4096, 4096 is displayed.
Used by: QP242,IP3
Cause: The referenced main and sub marks for the sequence in question are set to the same coordinates.