FUJI错误代码查询.pdf - 第2287页

Code: 52??1222 Display: No "UNIT", "MARK" - "BLOCK", "HEADER-". Used by: Cause: "BLOCK", "HEADER" was not found in "UNIT", "MARK" in the spe…

100%1 / 5282
program are in different files, the mark data referred to in the production program is required in the
applicable machine type and the above error is detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the mark data file referred to in
the production program.
------------------------------
Code: 52??1215
Display: "UNIT", "MARK" - "BLOCK", "MARKDT-" multiply defined for same mark.
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and "BLOCK", "MARKDT-" was
multiply defined for the same mark. This report is made if the mark data and production program are in
the same file and the above error is detected. When downloading, the first "BLOCK", "MARKDT-" is valid.
Remedy: At "MARKTYPE" in "UNIT", "MARK" - "BLOCK", "HEADER" in the production program, check that
the same mark is not multiply defined.
------------------------------
Code: 52??1216
Display: Mark data file "UNIT", "MARK" - "BLOCK", "HEADER-" format error.
Used by:
Cause: The mark data file referred to in the specified production program was read and an error detected
in the format of "BLOCK", "HEADER-" in "UNIT", "MARK. This report is made if the mark data and
production program are in different files, the mark data referred to in the production program is required
in the applicable machine type and the above error is detected.
Remedy: Check the settings in "UNIT", "MARK" - "BLOCK", "HEADER-" in the mark data file referred to in
the production program.
------------------------------
Code: 52??1217
Display: Mark data file "UNIT", "MARK" - "BLOCK", "MARKDT-" format error.
Used by:
Cause: The mark data file referred to in the specified production program was read and an error detected
in the format of "BLOCK", "MARKDT-" in "UNIT", "MARK. This report is made if the mark data and
production program are in different files, the mark data referred to in the production program is required
in the applicable machine type and the above error is detected.
Remedy: Check the settings in "UNIT", "MARK" - "BLOCK", "MARKDT-" in the mark data file referred to in
the production program.
------------------------------
Code: 52??1220
Display: No "UNIT", "MARK" or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" was not found in the specified production program or "UNIT", "MARK" does not
follow the correct unit. This report is made if the mark data and production program are in the same file
and the above error is detected.
Remedy: Check the settings in "UNIT", "MARK" in the production program. Also check the setting for the
"UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1221
Display: There is no "BLOCK" in "UNIT", "MARK".
Used by:
Cause: No "BLOCK" was found in "UNIT", "MARK" in the specified production program. This report is
made if the mark data and production program are in the same file and the above error is detected. The
relevant unit is ignored when downloading.
Remedy: Check the "UNIT", "MARK" setting in the production program.
------------------------------
第 2286 页
Code: 52??1222
Display: No "UNIT", "MARK" - "BLOCK", "HEADER-".
Used by:
Cause: "BLOCK", "HEADER" was not found in "UNIT", "MARK" in the specified production program. This
report is made if the mark data and production program are in the same file and the above error is
detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "HEADER" in the specified production
program.
------------------------------
Code: 52??1223
Display: No "UNIT", "MARK" - "BLOCK", "MARKDT-".
Used by:
Cause: "BLOCK", "MARKDT-" was not found in "UNIT", "MARK" in the specified production program.
This report is made if the mark data and production program are in the same file and the above error is
detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the specified production
program.
------------------------------
Code: 52??1224
Display: "UNIT", "MARK" - "BLOCK", "HEADER-" format error.
Used by:
Cause: "UNIT", "MARK" was read in the specified production program and a format error was detected in
"BLOCK", "HEADER-". This report is made if the mark data and production program are in the same file
and the above error is detected.
Remedy: Check the setting "UNIT", "MARK" - "BLOCK", "HEADER-" in the production program.
------------------------------
Code: 52??1225
Display: No "MARKTYPE" in "UNIT", "MARK" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "MARK" was read in the specified production program and there was no "MARKTYPE" in
"BLOCK", "HEADER-". This report is made if the mark data and production program are in the same file
and the above error is detected.
Remedy: Check the setting for "MARKTYPE" in "UNIT", "MARK"-"BLOCK" , "HEADER-".
------------------------------
Code: 52??1226
Display: "MARKTYPE" format error in "UNIT", "MARK" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "MARK" was read in the specified production program and a format error was detected in
"MARKTYPE" in "BLOCK", "HEADER-". This report is made if the mark data and production program are
in the same file and the above error is detected.
Remedy: Check the setting for "MARKTYPE" in "UNIT", "MARK" - "BLOCK", "HEADER-".
------------------------------
Code: 52??1227
Display: Format error in "UNIT", "MARK" - "BLOCK", "MARKDT-.
Used by:
Cause: "UNIT", "MARK" was read in the specified production program and a format error was detected in
"BLOCK", "MARKDT-". This report is made if the mark data and production program are in the same file
and the above error is detected.
Remedy: Check the settings for "UNIT", "MARK" - "BLOCK", "MARKDT" in the production program.
------------------------------
Code: 52??1230
第 2287 页
Display: There is a "UNIT", "MARK".
Used by:
Cause: Even though "UNIT", "MARK" is specified as being separate from the production program, "UNIT",
"MARK" exists in the production program. When downloading "UNIT", MARK" in the production program
is ignored.
Remedy: Check the "UNIT", "MARK" setting in the production program and the "FILESTRUCT" setting in
"UNIT", "STRUCT".
------------------------------
Code: 52??1231
Display: No "UNIT", "MARK" for F mark or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" for the F mark was not found in the specified production program or "UNIT",
"MARK" may not follow the correct unit. This report is made if the mark data and production program are
in the same file and the above error is detected. When downloading, the F mark data is set to its default
values.
Remedy: Check the setting for "UNIT", "MARK" in the production program. Furthermore, check the
setting for the "UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1232
Display: No "UNIT", "MARK" for B mark or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" for the B mark was not found in the specified production program or "UNIT",
"MARK" may not follow the correct unit. This report is made if the mark data and production program are
in the same file and the above error is detected. When downloading, the B mark data is set to its default
values.
Remedy: Check the setting for "UNIT", "MARK" in the production program. Furthermore, check the
setting for the "UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1233
Display: No "UNIT", "MARK" for M mark or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" for the M mark was not found in the specified production program or "UNIT",
"MARK" does not follow the correct unit. This report is made if the mark data and production program are
in the same file and the above error is detected. When downloading, the M mark data is set to its default
values.
Remedy: Check the setting for "UNIT", "MARK" in the production program. Furthermore, check the
setting for the "UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1234
Display: No "UNIT", "MARK" for G mark or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" for the G mark was not found in the specified production program or "UNIT",
"MARK" does not follow the correct unit. This report is made if the mark data and production program are
in the same file and the above error is detected. When downloading, the G mark data is set to its default
values.
Remedy: Check the setting for "UNIT", "MARK" in the production program. Furthermore check the setting
for the "UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1240
Display: Cannot find F mark file specification line.
Used by:
第 2288 页