------------------------------ Code: 1101161A Display: Used by: IP2 Cause: Holder 2, 3 and nozzle change check error (sequences 1251~1375) Remedy: Check the holder numbers on sequences 1251~1375. When the sequence specif…

100%1 / 5282
Remedy: Check the holder numbers on sequences 0376~0500. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 11011614
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 0501~0625)
Remedy: Check the holder numbers on sequences 0501~0625. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 11011615
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 0626~0750)
Remedy: Check the holder numbers on sequences 0626~0750. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 11011616
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 0751~875)
Remedy: Check the holder numbers on sequences 0751~0875. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 11011617
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 0876~1000)
Remedy: Check the holder numbers on sequences 0876~1000. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 11011618
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 1001~1125)
Remedy: Check the holder numbers on sequences 1001~1125. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 11011619
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 1126~1250)
Remedy: Check the holder numbers on sequences 1126~1250. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
第 38 页
------------------------------
Code: 1101161A
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 1251~1375)
Remedy: Check the holder numbers on sequences 1251~1375. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 1101161B
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 1376~1500)
Remedy: Check the holder numbers on sequences 1376~1500. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 1101161C
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 1501~1625)
Remedy: Check the holder numbers on sequences 1501~1625. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 1101161D
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 1626~1750)
Remedy: Check the holder numbers on sequences 1626~1750. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 1101161E
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 1751~1875)
Remedy: Check the holder numbers on sequences 1751~1875. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 1101161F
Display:
Used by: IP2
Cause: Holder 2, 3 and nozzle change check error (sequences 1876~2000)
Remedy: Check the holder numbers on sequences 1876~2000. When the sequence specifies holder 2 or
3, if there is a nozzle change between this point and the point at which nozzle size is selected, this error
occurs (IP2).
------------------------------
Code: 11011620
Display:
第 39 页
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0000~0125).
Remedy: Check the holder numbers at sequences 0000~0125. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011621
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0126~0250).
Remedy: Check the holder numbers at sequences 0126~0250. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011622
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0251~0375).
Remedy: Check the holder numbers at sequences 0251~0375. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011623
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0376~0500).
Remedy: Check the holder numbers at sequences 0376~0500. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011624
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0501~0625).
Remedy: Check the holder numbers at sequences 0501~0625. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011625
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0626~0750).
Remedy: Check the holder numbers at sequences 0626~0750. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011626
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0751~0875).