FUJI错误代码查询.pdf - 第1118页

Used by: CP-732E, CP-742ME, CP-742E Cause: The in-conveyor mid-stopper ON limit sensor failed to switch on. Although the in-conveyor mid- stopper was switched off, the OFF limit sensor failed to switch on within the pres…

100%1 / 5282
Display: In-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: In-carrier close was executed but in-carrier close limit sensor failed to switch on. An in-carrier
close was executed in order to retract the in-carrier from the advance limit position, but the open
confirmation sensor at the retract side failed to switch off within the prescribed period of time. An in-
carrier close was executed in order to advance the in-carrier from the retract limit position, but the open
confirmation sensor at the advance side failed to switch off within the prescribed period of time.
Remedy: Check to see if the in-carrier close operation has occurred correctly. Also verify that the in-
carrier open limit sensor is mounted at the correct position.
------------------------------
Code: 15040223
Display: In-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: An in-carrier open was executed but the in-carrier open limit sensor failed to switch on.
Remedy: Check to see if the in-carrier open operation has occurred correctly. Also verify that the in-
carrier open limit sensor is mounted at the correct position.
------------------------------
Code: 15040224
Display: In-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier clamper's open limit (clamp limit) sensor failed to switch on.
Remedy: The clamper must be closed in order to move the XY-table to the middle loading position. Check
to see if the in-carrier clamper is closed. If closed, and if this error occurs anyway, adjust the sensor
mounting position.
------------------------------
Code: 15040225
Display: In-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier panel sensors 1 and 2 (X0B1, X0B2) failed to switch on even though 2 panel s were
loaded from the in-lifter.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040226
Display: In-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier panel sensor 1 (X0B1) failed to switch on even though 1 panel was loaded from the
in-lifter.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040227
Display: In-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier panel sensor failed to switch on even though a panel was conveyed from the in-
lifter to the XY-table.
Remedy: Check to see if the panel was conveyed properly to the XY-table. If this error occurs even though
panel was conveyed properly, adjust the sensor mounting position.
------------------------------
Code: 15040228
Display: In-conveyor mid-stopper error.
第 1117 页
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-conveyor mid-stopper ON limit sensor failed to switch on. Although the in-conveyor mid-
stopper was switched off, the OFF limit sensor failed to switch on within the prescribed period of time (3
secs.).
Remedy: If this error occurs even though both the stopper ON and OFF limit sensors switch on within the
prescribed period of time, with the stopper operating correctly, check the operation of the sensors (X0C4,
X0C5).
------------------------------
Code: 15040229
Display: In-conveyor panel set error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Although single-board production is in effect, there are 2 boards on the in-lifter. Alternatively,
during double-board production, the X-direction size of the panel on the in-lifter exceeds the prescribed
size.
Remedy: The in-conveyor panel check revealed a panel problem on the in-conveyor. Verify that the
number of panel s on the in-lifter matches the number of panel s designated by the current production
mode (single-board production). If the panel s are being conveyed properly, verify that the sensors (X0AB,
X0AC, X0AE, X0AF) are operating properly. This error may also occur if there is a mid-stopper problem
which results in the panel s not stopping at the stopper position. The panel interval sensor should be on
when a panel is absent, and off when a panel is present.
------------------------------
Code: 1504022A
Display: 搬运轨道电路板确认传感器异常。
电路板载入异常 IN-MAIN(NXTP)
Used by: CP-732E,CP-742ME,CP-742E,NXTP
Cause: 载入搬运轨道电路板确认传感器异常。 载入侧搬运爪取入载入升降台上的电路板,移动到载入侧搬运爪前进
端完成电路板搬运时,确认载入升降台上的电路板的传感器检测出电路板了。
没有正常地进行从载入搬运轨道向主搬运轨道电路板搬送。(NXTP)
Remedy: 请确认传感器(X0AB,X0AC,X0AD,X0AF)确实动作。 此外,确认电路板间隙传感器在没有电路板时
ON,有的时候OFF。
1.请确认搬运轨道间的电路板载入是否顺畅。(NXTP)
2.请确认IN到达传感器(RX04A)能正常检测电路板。(NXTP)
<img src="$LKEY_ERRIMG_MC$/1504022A.PNG">
------------------------------
Code: 1504022B
Display: In-conveyor panel sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier 1 panel sensor or the in-carrier 2 panel sensor switched on while the in-carrier was
being advanced after a panel was loaded from the in-lifter to the in-carrier. The in-carrier 1 panel sensor
or the in-carrier 2 panel sensor remained on for 0.5 seconds when the XY-table was at its DOWN limit or
loading position with the in-carrier open at its advance limit position.
Remedy: Check to see if the sensors (X0B1, X0B2) are operating properly.
------------------------------
Code: 1504022C
Display: In-lifter cycle error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-lifter UP limit sensor failed to switch on. The in-lifter was lowered but the DOWN limit
sensor failed to switch on within the prescribed time period (3 secs.).
Remedy: Check to see if the in-lifter is operating smoothly. If operation is smooth, but the error still
occurs, check to see if the sensors (X0B5, X0B6) are operating properly.
------------------------------
第 1118 页
Code: 1504022D
Display: In-carrier cycle error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The in-carrier advance limit sensor failed to switch on. The in-carrier was retracted but the
retract limit sensor failed to switch on within the prescribed time period (8 secs.).
Remedy: Check to see if the in-carrier is operating smoothly. If operation is smooth, but the error still
occurs, check to see if the sensors (X0B3, X0B4) are operating properly.
------------------------------
Code: 1504022E
Display: In-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: After conveying the panel to the advance limit position with the panel being confirmed by the in-
carrier 1 panel sensor and the in-carrier 2 panel sensor, these sensors both switched off before the panel
could be loaded from the in-carrier to the in-lifter, resulting in a panel absent condition on the in-carrier.
In systems with an in-carrier panel present memory, the panel present/absent status on the in-carrier
was checked, but the in-carrier 1 panel sensor and the in-carrier 2 panel sensor could not verify the
presence of a panel .
Remedy: Check the panel conveyance condition. If there is no panel on the in-carrier, use the in-carrier
unclamp command to open the in-carrier. If this error occurs even though panel s are being conveyed
properly, check to see if the sensors (X0B1, X0B2) are operating properly.
------------------------------
Code: 1504022F
Display: In-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: At the in-carrier panel check, the in-carrier 1 panel sensor (X0B1) and the in-carrier 2 panel
sensor (X0B2) both switched on.
Remedy: Check the panel conveyance condition. If this error occurs even though the panel s are being
conveyed properly, check to see if the sensors (X0B1, X0B2) are operating properly.
------------------------------
Code: 15040230
Display: In-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: After panel loading to the in-lifter from the in-carrier began, the in-conveyor 1 panel arrival
sensor or the in-conveyor 2 panel arrival sensor switched from on to off before the in-carrier could be
advanced.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensors (X0AC, X0AE) are operating properly.
------------------------------
Code: 15040231
Display: In-carrier unclamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: In-carrier unclamp limit sensor input error.
Remedy: Verify that the sensors (X0B7 to X0BA) are operating properly.
------------------------------
Code: 15040232
Display: In-carrier clamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: In-carrier clamp limit sensor input error.
Remedy: Verify that the sensors (X0BB to X0BE) are operating properly.
------------------------------
Code: 15040233
第 1119 页