------------------------------ Code: 15032003 Display: IN-car for/bck lmt both ON Used by: CP643 Cause: The in-carrier extended sensor and retracted sensor are both ON. Remedy: Check the in-carrier extended sensor (LX01C…
Code: 1503100F
Display: 确认电路板通过失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 确认电路板通过失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认MAIN通过传感器是否正常地动作。
------------------------------
Code: 15031010
Display: 向次工序的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 向次工序的电路板搬运失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认从次工程来的要求电路板信号是否正常地动作。
------------------------------
Code: 15031011
Display: 向MAIN搬运轨道的电路板减速传感器的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 向MAIN搬运轨道的电路板减速传感器的电路板搬运失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认电路板减速信号是否正常地动作。
------------------------------
Code: 15031012
Display: IN搬运轨道的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: IN搬运轨道的电路板搬运失败。
Remedy: 请确认电路板是否正常地运行至IN搬运轨道到达传感器。
请确认从前工程来的可以搬运电路板信号(X018:PcbAvailable)是否正常地动作。
------------------------------
Code: 15031013
Display: 搬运轨道宽度与前工序不一致。
Used by: XP142,XP242
Cause: 搬运轨道宽度与前工序不一致。
Remedy: ·请确认前工序和本机器的搬运轨道宽度。
·搬运轨道宽度没有问题时,请确认+跟踪确认传感器(X059)、以及、-跟踪确认传感器(X05A)是否正常地动
作。
·+跟踪确认传感器(X059)、以及、-跟踪确认传感器(X05A)未安装的机器上,请设定固有值「
__ConveyorFollowCheck」为"0"。
------------------------------
Code: 15031014
Display: 在IN升降台下降后IN平台电路板到达确认传感器没作出反应。
Used by: XP142,XP143,XP242,XP243
Cause: 在IN升降台下降后IN平台电路板到达确认传感器没作出反应。
Remedy: 请确认IN平台的电路板的位置是否在IN平台电路板到达确认传感器作出反应的位置。
请确认IN平台电路板到达确认传感器在正常工作。
------------------------------
Code: 15032002
Display: IN-car for/bck lmt both OFF
Used by: CP643
Cause: The in-carrier extended sensor and retracted sensor are both OFF.
Remedy: Check the in-carrier extended sensor (LX01C) and the in-carrier retracted sensor (LX01D). if the
carrier is stopped between the sensors,move the in-carrier either forward or backward.
第 1107 页
------------------------------
Code: 15032003
Display: IN-car for/bck lmt both ON
Used by: CP643
Cause: The in-carrier extended sensor and retracted sensor are both ON.
Remedy: Check the in-carrier extended sensor (LX01C) and the in-carrier retracted sensor (LX01D).
------------------------------
Code: 15032004
Display: IN-car clp limits both OFF:extended limit
Used by: CP643
Cause: The in-carrier extended limit claws closed sensors and the in-carrier extended limit claws opened
sensors are both OFF.
Remedy: Check the in-carrier extended limit claws closed sensors (LX042,LX043)
and the in-carrier extended limit claws opened sensors (LX046,LX047). if the in-carrier clamp is stopped
between the sensors,either open or close the in-carrier.
------------------------------
Code: 15032005
Display: IN-car clp limits both ON:extended limit
Used by: CP643
Cause: The in-carrier extended limit claws closed sensors and the in-carrier extended limit claws opened
sensors are both ON.
Remedy: Check the in-carrier extended limit claws closed sensors (LX042,LX043)
and the in-carrier extended limit claws opened sensors (LX046,LX047).
------------------------------
Code: 1503200A
Display: OUT-car for/bck lmt both OFF
Used by: CP643
Cause: The out-carrier extended sensor and retracted sensor are both OFF.
Remedy: Check the out-carrier extended sensor (LX03C) and the out-carrier retracted sensor (LX03D). if
the carrier is stopped between the sensors,move the in-carrier either forward or backward.
------------------------------
Code: 1503200B
Display: OUT-car for/bck lmt both ON
Used by: CP643
Cause: The out-carrier extended sensor and retracted sensor are both ON.
Remedy: Check the out-carrier extended sensor (LX03C) and the out-carrier retracted sensor (LX03D).
------------------------------
Code: 1503200C
Display: OUT-car clp limits both OFF:extended limit
Used by: CP643
Cause: The out-carrier extended limit claws closed sensors and the out-carrier extended limit claws
opened sensors are both OFF.
Remedy: Check the out-carrier extended limit claws closed sensors (LX048,LX049)and the out-carrier
extended limit claws opened sensors (LX04C,LX04D). if the out-carrier clamp is stopped between the
sensors,either open or close the out-carrier.
------------------------------
Code: 1503200D
Display: OUT-car clp limits both ON:extended limit
Used by: CP643
Cause: The out-carrier extended limit claws closed sensors and the out-carrier extended limit claws
opened sensors are both ON.
第 1108 页
Remedy: Check the out-carrier extended limit claws closed sensors (LX048,LX049)and the out-carrier
extended limit claws opened sensors (LX04C,LX04D).
------------------------------
Code: 15032010
Display: MAIN搬运轨道减速·到达·通过传感器上有电路板,因阻挡块没有上升而不能启动自动运转。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道减速·到达·通过传感器上有电路板,因阻挡块没有上升而不能启动自动运转。
Remedy: 在搬运轨道操作画面上使阻挡块上升后再启动机器。
无论是否有电路板,只要出现这个错误时,就请确认MAIN搬运轨道减速·到达·通过传感器是否正常地动作。
------------------------------
Code: 15032011
Display: 向确认OUT通过传感器的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 电路板没有正常地流向OUT通过传感器。
Remedy: 请确认电路板是否在搬运途中停留。
没有电路板时,请确认OUT通过确认传感器是否正常地动作。
------------------------------
Code: 15032012
Display: OUT搬运轨道上有电路板,因从次工序来的要求电路板信号处于OFF,所以不能送出。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: OUT搬运轨道上有电路板,因从次工序来的要求电路板信号处于OFF,所以不能送出。
Remedy: ·从次工序来的要求电路板信号处于ON的状态,请启动机器。
·请除去OUT搬运轨道上的电路板后再启动。
·无论是否有电路板,只要出现这个错误时,就请确认MAIN通过传感器是否正常地动作。
------------------------------
Code: 15034001
Display: Cycle Alarm Servo ??
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: The servo did not reach its target position within the preset time limit.
Remedy: Undecided.
------------------------------
Code: 15034002
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: The cylinder did not reach its target position within the preset time limit.
Remedy: Undecided.
------------------------------
Code: 15034003
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: The conveyor did not reach its target position within the preset time limit.
Remedy: Undecided.
------------------------------
Code: 15034004
Display:
Used by: CP4-1,CP4-2,CP4-3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: The lifter did not reach its target position within the preset time limit.
Remedy: Undecided.
------------------------------
Code: 15034005