Used by: CP5,CP6M,CP65,CP652C,CP642,CP643 Cause: The quantity of cooling oil is not sufficient. There is a fault in the circulating motor. There is a fault in the detecting sensor. Remedy: Switch off the machine power an…
Cause: Either the very fine tool probe does not advance, or it does not retract.
Remedy: Adjust the probe.
------------------------------
Code: 12061009
Display: VF Meter Er
Used by: CP3
Cause: Data was not returned from the very fine tool or from the LCR meter.
Remedy: Check that the connector and the lines have not been cut.
------------------------------
Code: 1206100A
Display: CHECK CAM
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam axis was not returned to the zero position.
Remedy: Using the cam handle, return the cam to the zero position.
------------------------------
Code: 1206100B
Display: Carrier Position Err. IN
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis in position is the Proper data Pallet Position DF
IN plus 500. Inch the axis to a point in this range.
------------------------------
Code: 1206100C
Display: Carrier Position Err. WORK
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis in position is the Proper data Pallet Position DF
IN plus 500. The D axis out position is the Proper data Pallet Position DF OUT minus 500. Inch the axis
to a point in this range.
------------------------------
Code: 1206100D
Display: Carrier Position Err. OUT
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis out position is the Proper data Pallet Position
DF OUT minus 500. Inch the axis to a point in this range.
------------------------------
Code: 1206100E
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: A nozzle has hit the parts in the rejected parts box.
Remedy: Empty the box.
------------------------------
Code: 1206100F
Display:
Used by: CP5
Cause: The Z origin position (Z0) in the machine has changed.
Remedy: Check that the coupling is not loose. If adjustments are necessary, readjust the Z axis.
------------------------------
Code: 12061010
Display: Coolant oil circulat prob.(cp6)
第 598 页
Used by: CP5,CP6M,CP65,CP652C,CP642,CP643
Cause: The quantity of cooling oil is not sufficient. There is a fault in the circulating motor. There is a
fault in the detecting sensor.
Remedy: Switch off the machine power and check if the oil quantity is within specifications. Check the
circulating motor and the detecting sensor.
------------------------------
Code: 12061012
Display: Nzl origin search err stn12.(cp6)
Used by:
Cause: The nozzle origin position cannot be found.
Remedy: If this error occurs often and at random (ie: not always in the same nozzle), check the
adjustment of the origin position sensor. If this error occurs in a specific nozzle, check the clutch section
of this nozzle.
------------------------------
Code: 12061013
Display: Pallet ID Zero Error
Used by: CP652C
Cause: The result of reading the pallet ID of the pallet on the up-elevator was a pallet ID of "0".
Remedy: Use the pallet ID write command to set a proper ID_No. A value from 1 to 255 can be used as a
valid ID_No. Refer to the Operation Manual for information regarding the ID_No write command.
------------------------------
Code: 12061014
Display: "Ref. side clamp mesh error" (CP-642)
Used by: CP642,CP643
Cause: The guiderail on the XY table did not mesh with the guide on the conveyor.
Remedy: Align the XY table guiderail with the guide on the conveyor.
------------------------------
Code: 12061015
Display: "Interfered with backup pin"
Used by: CP642,CP643
Cause: The XY table structure interfered with the backup pin.
Remedy: Change the position of the backup pin.
------------------------------
Code: 12061016
Display: "ST15 nozzle origin error.", "Return nzl hldr to org pos." (CP6/6M)
Used by: CP6,CP6M,CP65,CP642,CP643
Cause: A Station 15 nozzle origin position check failed to confirm the origin.
Remedy: Return the nozzle holder to a position near the origin. (Nozzle disorientation may occur after
continuous production involving 90[deg] rotation.) If this error occurs even though the nozzleholder is at
the origin position, the Station 15 origin position check sensor requires adjustment.
------------------------------
Code: 12061017
Display: ST1:Nozzle up/down error
ST1:UP-lmt sensor OFF
Used by: CP643
Cause: The ST1 cylinder upper limit sensor was OFF even though the stopper has been engaged to
prevent the nozzle at ST1 from descending,after the head at ST20 was a skipped head during D-axis
positioning or D-axis retraction at the start of automatic operation.
Remedy: Check the ST1 stopper and the ST1 cylinder upper limit sensor(X06A)
------------------------------
Code: 12061018
第 599 页
Display: ST1:Nozzle up/down error
ST1:UP-lmt sensor ON
Used by: CP643
Cause: The ST1 cylinder upper limit sensor is ON even though the machine has lowered the nozzle at
ST1 to pick up a part.
Remedy: Check the ST1 cylinder upper limit sensor(X06A)
------------------------------
Code: 12061019
Display: ST11:Nozzle up/down error
ST11:UP-lmt sensor OFF
Used by: CP643
Cause: The ST11 cylinder upper limit sensor was OFF even though the stopper has been engaged to
prevent the nozzle at ST11 from descending,after the head at ST10 was a skipped head during at the start
of automatic operation.
Remedy: Check the ST11 stopper and the ST11 cylinder upper limit sensor(X06B)
------------------------------
Code: 1206101A
Display: ST11:Nozzle up/down error
ST11:UP/DWN sensor error
Used by: CP643
Cause: Both the cylinder upper limit and lower limit sensors are ON even though the machine has
lowered the nozzle ae ST11 to place a part.
Remedy: Check the ST11 cylinder upper limit sensor(X06B)
------------------------------
Code: 1206101B
Display: Production method does not match
Check Proper and header data
Used by: CP643
Cause: The production program item "Multiple pcb set" is set to "2", even though the Proper data item
"mc_pcb_type" is set to "1". These data do not match.
Remedy: Use one of the following remedies.
1. Set Proper item "mc_pcb_type" to "0".
2. Set the production program item "Multiple pcb set" to "1" and ensure there is only one board's worth of
sequences in the sequence data.
------------------------------
Code: 1206101C
Display: Nozzle holder origin position error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The nozzle holder is not at its origin position.
Remedy: Frequent occurrences of this error at the same shaft indicates a shaft rotation problem.
------------------------------
Code: 1206101D
Display: Parts height sensor malfunction.
Used by: CP-742ME, CP-742E, CP-752E
Cause: Parts height sensor is soiled.
Remedy: Wipe the sensor beam emitter and receptor lenses with a soft object such as a cotton swab, etc.
------------------------------
Code: 1206101E
Display: Parts height sensor error.
Used by: CP-742ME, CP-742E, CP-752E
Cause: Parts height sensor processing was not completed in the prescribed period of time.