Coarse_edge_d2 Coarse_edge_e1_polarity Coarse_edge_e3_polarity break_rate max_break ------------------------------ Code: 1C410123 Display: Used by: Cause: Pickup tolerance is too large. Remedy: Make the GD tolerances (pi…

100%1 / 5282
Remedy: Change the center tolerance (l center tolerance).
------------------------------
Code: 1C410115
Display:
Used by:
Cause: D center tolerance error. D direction center tolerance error. This error can occur at the end of
device inspection, and the corresponding tolerance check cannot be disabled.
Remedy: Change the center tolerance (d center tolerance).
------------------------------
Code: 1C410116
Display:
Used by:
Cause: H position error.
Remedy: The pickup point has moved. This generally means that the part pickup rate is bad. Check the
pickup conditions at the monitor.
------------------------------
Code: 1C410117
Display:
Used by:
Cause: V position error.
Remedy: The pickup point has moved. This generally means that the part pickup rate is bad. Check the
pickup conditions at the monitor.
------------------------------
Code: 1C410118
Display:
Used by:
Cause: Angle position error.
Remedy: The pickup point has moved. This generally means that the part pickup rate is bad. Check the
pickup conditions at the monitor.
------------------------------
Code: 1C410120
Display:
Used by:
Cause: The part is too large.
Remedy: Check the relevant specifications.
------------------------------
Code: 1C410121
Display:
Used by:
Cause: There is no coarse edge in GD.
Remedy: Check the coarse edge in the GD editor.
------------------------------
Code: 1C410122
Display:
Used by:
Cause: When using a frontlight, a coarse edge is necessary.
Remedy: Check the device description.
Coarse_edge_angle
Coarse_edge_l1
Coarse_edge_d1
Coarse_edge_l2
第 1180 页
Coarse_edge_d2
Coarse_edge_e1_polarity
Coarse_edge_e3_polarity
break_rate
max_break
------------------------------
Code: 1C410123
Display:
Used by:
Cause: Pickup tolerance is too large.
Remedy: Make the GD tolerances (pickup tolerance x, pickup tolerance y, rotation tolerance) smaller. This
error generally means that part pickup rates are bad. Check pickup conditions at the monitor.
------------------------------
Code: 1C410124
Display:
Used by:
Cause: Pickup tolerance is too large.
Remedy: Make the GD tolerances (pickup tolerance x, pickup tolerance y, rotation tolerance) smaller. This
error generally means that part pickup rates are bad. Check pickup conditions at the monitor.
------------------------------
Code: 1C410125
Display:
Used by:
Cause: A preset time limit has been exceeded.
Remedy: Set Part data's PD.Cam_speed lower. Check to see if the part can be placed at 100% cam speed.
------------------------------
Code: 1C410126
Display:
Used by:
Cause: Even though coarse edge was performed, the pickup tolerance is too large.
Remedy: Make the GD tolerances (pickup tolerance x, pickup tolerance y, rotation tolerance) smaller.
------------------------------
Code: 1C410127
Display:
Used by:
Cause: The coarse edge could not be found.
Remedy: Set up a correct coarse edge description. Check the following:
Coarse_edge_angle
Coarse_edge_l1
Coarse_edge_d1
Coarse_edge_l2
Coarse_edge_d2
Coarse_edge_e1_polarity
Coarse_edge_e3_polarity
break_rate
max_break
------------------------------
Code: 1C410128
Display:
Used by:
Cause: Training cannot be done because the pickup tolerance is too large.
第 1181 页
Remedy: Make the device description tolerance settings (pickup tolerance x, pickup tolerance y, rotation
tolerance) smaller. Generally, if the parts are small, the edge of the nozzle protrudes, and this makes the
vacuum weaker, and the parts can therefore easily slide after vision processing is complete. Caution must
be exercised on this point.
------------------------------
Code: 1C410129
Display:
Used by:
Cause: Training cannot be done because the coarse edge is incorrect.
Remedy: Enter a correct device description coarse edge. Check the following:
Coarse_edge_angle
Coarse_edge_l1
Coarse_edge_d1
Coarse_edge_l2
Coarse_edge_d2
Coarse_edge_e1_polarity
Coarse_edge_e3_polarity
break_rate
max_break
------------------------------
Code: 1C410130
Display:
Used by:
Cause: The coarse edge pickup tolerance is too large.
Remedy: Make the device description tolerance settings (pickup tolerance x, pickup tolerance y, rotation
tolerance) smaller.
------------------------------
Code: 1C410131
Display:
Used by:
Cause: The coarse edge tolerance (positional uncertainty) is too large.
Remedy: Make the generic device description tolerance settings (pickup tolerance x, pickup tolerance y,
rotation tolerance) smaller.
------------------------------
Code: 1C410132
Display:
Used by:
Cause: The blob cannot be found in the nozzle position.
Remedy: If the nozzle seen at the monitor is not dirty, this is probably a hardware problem.
------------------------------
Code: 1C410133
Display:
Used by:
Cause: A blob analysis failed to determine the device rotation angle during inspection. However, device
training indicated that the angle could be determined. Therefore the run-time image is not what the
software expects based on the device description. Pickup uncertainty is large enough to require that blob
analysis be used during device inspection. In such cases, during device training, the system uses the
device description to predict whether useful angle information will appear in the blob results. If the
system expects angle information to appear and it does not, then this error occurs.
Remedy: Check that the direction is correct. Also, check the part placement direction in PD. If the nozzle
edge protrudes from the part (the nozzle is too large) this error can also occur. Either improve the
第 1182 页