FUJI错误代码查询.pdf - 第765页

9: slot number 5 sub-slot number 0 or 1 A: slot number 5 sub-slot number 2 B: slot number 6 sub-slot number 0 or 1 C: slot number 6 sub-slot number 2 Remedy: Use the Origin SW at the feeder panel to execute origin positi…

100%1 / 5282
2: slot number 1 sub-slot number 2
3: slot number 2 sub-slot number 0 or 1
4: slot number 2 sub-slot number 2
5: slot number 3 sub-slot number 0 or 1
6: slot number 3 sub-slot number 2
7: slot number 4 sub-slot number 0 or 1
8: slot number 4 sub-slot number 2
9: slot number 5 sub-slot number 0 or 1
A: slot number 5 sub-slot number 2
B: slot number 6 sub-slot number 0 or 1
C: slot number 6 sub-slot number 2
Remedy: Re-set the feeder at the PFU and re-execute the association.
------------------------------
Code: 12073??2
Display: "Feeding operation time-out"
"PM?? [******]"
"Err Code: 12073??2"
Used by: QP132
Cause: The response to a feed request (feeder) failed to occur within the prescribed period of time.
(value replacing "??" is module number; command name appears in place of asterisks.)
(The first digit of "??" represents the module number; the second digit represents the slot position.)
1: slot number 1 sub-slot number 0 or 1
2: slot number 1 sub-slot number 2
3: slot number 2 sub-slot number 0 or 1
4: slot number 2 sub-slot number 2
5: slot number 3 sub-slot number 0 or 1
6: slot number 3 sub-slot number 2
7: slot number 4 sub-slot number 0 or 1
8: slot number 4 sub-slot number 2
9: slot number 5 sub-slot number 0 or 1
A: slot number 5 sub-slot number 2
B: slot number 6 sub-slot number 0 or 1
C: slot number 6 sub-slot number 2
Remedy: Use the origin SW at the feeder panel to execute origin positioning, then try the operation again.
------------------------------
Code: 12073??3
Display: "Feeder origin error"
"PM?? [******]"
"Err Code: 12073??3"
Used by: QP132
Cause: The feeder motor is not at its origin position.
(value replacing "??" is module number; command name appears in place of asterisks.)
(The first digit of "??" represents the module number; the second digit represents the slot position.)
1: slot number 1 sub-slot number 0 or 1
2: slot number 1 sub-slot number 2
3: slot number 2 sub-slot number 0 or 1
4: slot number 2 sub-slot number 2
5: slot number 3 sub-slot number 0 or 1
6: slot number 3 sub-slot number 2
7: slot number 4 sub-slot number 0 or 1
8: slot number 4 sub-slot number 2
第 764 页
9: slot number 5 sub-slot number 0 or 1
A: slot number 5 sub-slot number 2
B: slot number 6 sub-slot number 0 or 1
C: slot number 6 sub-slot number 2
Remedy: Use the Origin SW at the feeder panel to execute origin positioning.
------------------------------
Code: 12073??4
Display: "Feeder motor error"
"PM?? [******]"
"Err Code: 12073??4"
Used by: QP132
Cause: A malfunction has occurred at the feeder motor.
(value replacing "??" is module number; command name appears in place of asterisks.)
(The first digit of "??" represents the module number; the second digit represents the slot position.)
1: slot number 1 sub-slot number 0 or 1
2: slot number 1 sub-slot number 2
3: slot number 2 sub-slot number 0 or 1
4: slot number 2 sub-slot number 2
5: slot number 3 sub-slot number 0 or 1
6: slot number 3 sub-slot number 2
7: slot number 4 sub-slot number 0 or 1
8: slot number 4 sub-slot number 2
9: slot number 5 sub-slot number 0 or 1
A: slot number 5 sub-slot number 2
B: slot number 6 sub-slot number 0 or 1
C: slot number 6 sub-slot number 2
Remedy: Re-execute the association. If the error occurs repeatedly, replace the feeder.
------------------------------
Code: 12073??5
Display: "Domain refresh count over"
"PM?? [******]"
"Err Code: 12073??5"
Used by: QP132
Cause: The guaranteed refresh count for the feeder's LON chip has been reached.
(value replacing "??" is module number; command name appears in place of asterisks.)
(The first digit of "??" represents the module number; the second digit represents the slot position.)
1: slot number 1 sub-slot number 0 or 1
2: slot number 1 sub-slot number 2
3: slot number 2 sub-slot number 0 or 1
4: slot number 2 sub-slot number 2
5: slot number 3 sub-slot number 0 or 1
6: slot number 3 sub-slot number 2
7: slot number 4 sub-slot number 0 or 1
8: slot number 4 sub-slot number 2
9: slot number 5 sub-slot number 0 or 1
A: slot number 5 sub-slot number 2
B: slot number 6 sub-slot number 0 or 1
C: slot number 6 sub-slot number 2
Remedy: Replace either the feeder or the feeder PCB.
------------------------------
Code: 12073??6
第 765 页
Display: "Domain cannot be referenced"
"PM?? [******]"
"Err Code: 12073??6"
Used by: QP132
Cause: The feeder's LON chip domain table cannot be referenced.
(value replacing "??" is module number; command name appears in place of asterisks.)
(The first digit of "??" represents the module number; the second digit represents the slot position.)
1: slot number 1 sub-slot number 0 or 1
2: slot number 1 sub-slot number 2
3: slot number 2 sub-slot number 0 or 1
4: slot number 2 sub-slot number 2
5: slot number 3 sub-slot number 0 or 1
6: slot number 3 sub-slot number 2
7: slot number 4 sub-slot number 0 or 1
8: slot number 4 sub-slot number 2
9: slot number 5 sub-slot number 0 or 1
A: slot number 5 sub-slot number 2
B: slot number 6 sub-slot number 0 or 1
C: slot number 6 sub-slot number 2
Remedy: If the error still occurs after several association attempts, replace either the feeder or the feeder
PCB.
------------------------------
Code: 12073??7
Display: "Domain cannot be refreshed"
"PM?? [******]"
"Err Code: 12073??7"
Used by: QP132
Cause: The feeder's LON chip domain table cannot be refreshed.
(value replacing "??" is module number; command name appears in place of asterisks.)
(The first digit of "??" represents the module number; the second digit represents the slot position.)
1: slot number 1 sub-slot number 0 or 1
2: slot number 1 sub-slot number 2
3: slot number 2 sub-slot number 0 or 1
4: slot number 2 sub-slot number 2
5: slot number 3 sub-slot number 0 or 1
6: slot number 3 sub-slot number 2
7: slot number 4 sub-slot number 0 or 1
8: slot number 4 sub-slot number 2
9: slot number 5 sub-slot number 0 or 1
A: slot number 5 sub-slot number 2
B: slot number 6 sub-slot number 0 or 1
C: slot number 6 sub-slot number 2
Remedy: If the error persists after several association attempts, replace either the feeder or the feeder
PCB.
------------------------------
Code: 12073??8
Display: "No response from feeder."
"PM?? [******]"
"Err Code: 12073??8"
Used by: QP132
Cause: Feeder fails to respond to ON/OFF request within time limit.
第 766 页