FUJI错误代码查询.pdf - 第2321页
------------------------------ Code: 52??1831 Display: No item definition for "GUISTN". Used by: Cause: "UNIT", "PALLET" in the specified pallet data file was read and the "GUISTN"…
Code: 52??1813
Display: No "UNIT", "PALLET" - "BLOCK", "HEADER-" in the pallet data file.
Used by:
Cause: The specified pallet data file was read and "BLOCK", "HEADER-" in "UNIT", "PALLET" was not
found.
Remedy: Check the setting for "UNIT", "PALLET" - "BLOCK", "HEADER-" in the specified pallet data file.
------------------------------
Code: 52??1814
Display: No "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the pallet data file.
Used by:
Cause: The specified pallet data file was read and "BLOCK", "PLTDT+" in "UNIT", "PALLET" was not
found.
Remedy: Check the setting for "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the specified pallet data file.
------------------------------
Code: 52??1815
Display: Format error in "UNIT", "PALLET" - "BLOCK", "HEADER-" in pallet data file.
Used by:
Cause: The specified pallet data file was read and a format error was detected in "BLOCK", "HEADER-" in
"UNIT", "PALLET".
Remedy: Check the setting for "UNIT", "PALLET" - "BLOCK", "HEADER-" in the specified pallet data file.
------------------------------
Code: 52??1816
Display: Format error in "UNIT", "PALLET" - "BLOCK", "PLTDT+" in pallet data file.
Used by:
Cause: The specified pallet data file was read and a format error was detected in "BLOCK", "PLTDT+" in
"UNIT", "PALLET".
Remedy: Check the setting for "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the specified pallet data file.
------------------------------
Code: 52??1820
Display: Format error in "MCTYPE" in "UNIT", "PALLET" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and a format error was detected in
"MCTYPE" in "BLOCK", "HEADER-".
Remedy: Check the setting for "MCTYPE" in "UNIT", "PALLET" - "BLOCK", "HEADER-" in the specified
pallet data file.
------------------------------
Code: 52??1821
Display: Format error in "NAME" in "UNIT", "PALLET" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and a format error was detected in
"NAME" in "BLOCK", "HEADER-".
Remedy: Check the setting for "NAME" in "UNIT", "PALLET" - "BLOCK", "HEADER-" in the specified pallet
data file.
------------------------------
Code: 52??1830
Display: No item definition line in "UNIT", "PALLET" - "BLOCK", "PLTDT+".
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and the item definition line for
"BLOCK", "PLTDT+" was not found.
Remedy: Check the setting for the item definition line for "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the
specified pallet data file.
第 2320 页
------------------------------
Code: 52??1831
Display: No item definition for "GUISTN".
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and the "GUISTN" entry in the
"BLOCK", "PLTDT+" item definition line was not found.
Remedy: Check the setting for "GUISTN" in the "UNIT", "PALLET" - "BLOCK", "PLTDT+" item definition line
in the specified pallet data file. "GUISTN" is a mandatory item.
------------------------------
Code: 52??1832
Display: Out of range value in "GUISTN" data.
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and there was an out of range value in
the "GUISTN" data in "BLOCK", "PLTDT+". When downloading, the relevant data is ignored.
Remedy: Check the setting for the "GUISTN" data line in "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the
specified pallet data file.
------------------------------
Code: 52??1833
Display: Insufficient values entered for "GUISTN"
Used by:
Cause: "UNIT", "PALLET" in the specified pallet data file was read and the data lines for "GUISTN" in
"BLOCK", "PLTDT+" were insufficient.
Remedy: Check the settings for the "GUISTN" data lines in "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the
specified pallet data file. "GUISTN" must record all of the numbers from 1 up to the number required by
the applicable machine type.
------------------------------
Code: 52??2000
Display: No "UNIT", "PALLET" or "UNIT", "PALLET" is not at the correct position.
Used by:
Cause: "UNIT", "PROPER" was not found in the specified Proper data. Alternatively, "UNIT", "PROPER"
does not follow the correct unit.
Remedy: Check the setting for "UNIT", "PROPER" in the Proper data.
------------------------------
Code: 52??2001
Display: No ""UNIT", "PROPER" - "BLOCK", "HEADER-".
Used by:
Cause: "BLOCK", "HEADER-" was not found in "UNIT", "PROPER" in the specified Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "HEADER-" in the Proper data.
------------------------------
Code: 52??2002
Display: No ""UNIT", "PROPER" - "BLOCK", "PROPDT-".
Used by:
Cause: "BLOCK", "PROPDT-" was not found in "UNIT", "PROPER" in the specified Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "PROPDT-" in the Proper data.
------------------------------
Code: 52??2005
Display: No ""UNIT", "PROPER" - "BLOCK", "IMAGE-".
Used by:
Cause: "BLOCK", "IMAGE" was not found in "UNIT", "PROPER" in the specified transmission image type
Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "IMAGE-" in the Proper data. Furthermore,
第 2321 页
check "FILESTRUCT" in "UNIT", "STRUCT".
------------------------------
Code: 52??2006
Display: No vQN line in "UNIT", "PROPER" - "BLOCK", "IMAGE-".
Used by:
Cause: The vQN line was not found in "UNIT", "PROPER" - "BLOCK", "IMAGE" in the specified
transmission image type Proper data.
Remedy: Check the content of "UNIT", "PROPER" - "BLOCK", "IMAGE-" in the production program.
------------------------------
Code: 52??2011
Display: Format error in "UNIT", "PROPER" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "PROPER" in the specified Proper data was read and a format error was detected in
"BLOCK", "HEADER-".
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "HEADER-" in the Proper data.
------------------------------
Code: 52??2012
Display: Format error in "UNIT", "PROPER" - "BLOCK", "PROPDT-".
Used by:
Cause: "UNIT", "PROPER" in the specified Proper data was read and a format error was detected in
"BLOCK", "PROPDT-".
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "PROPDT-" in the Proper data.
------------------------------
Code: 52??2100
Display: No "UNIT", "STATUS" or "UNIT", "STATUS" is not at the correct position.
Used by:
Cause: "UNIT", "STATUS" was not found in the specified status data or "UNIT", "STATUS" does not follow
the correct unit.
Remedy: Check the "UNIT", "STATUS" setting in status data. Alternatively, check the setting of the "UNIT"
line prior to "UNIT", "STATUS".
------------------------------
Code: 52??2101
Display: No "UNIT", "STATUS" - "BLOCK", "HEADER-".
Used by:
Cause: "BLOCK", "HEADER-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS" - "BLOCK", "HEADER-".
------------------------------
Code: 52??2102
Display: No "UNIT", "STATUS" - "BLOCK", "STATDT-".
Used by:
Cause: "BLOCK", "STATDT-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS" - "BLOCK", "STATDT-".
------------------------------
Code: 52??2105
Display: No "UNIT", "STATUS" - "BLOCK", "IMAGE-".
Used by:
Cause: "BLOCK", "IMAGE-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS"-"BLOCK", "IMAGE-". Furthermore, check
"FILESTRUCT" in "UNIT", "STRUCT".
------------------------------
Code: 52??2106
第 2322 页