FUJI错误代码查询.pdf - 第1331页
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified. Remedy: Specify Qty_0. ------------------------------ Code: 1D0A8121 Display: Used by: Cause: Qty_1 (the number of leads on the low…
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D0A8100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D0A8110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D0A8111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D0A8112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D0A8113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D0A8114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D0A8115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D0A8120
Display:
Used by:
第 1330 页
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D0A8121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D0A8122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D0A8123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D0A82??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A83??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A84??
Display:
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A85??
Display:
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A88??
Display:
第 1331 页
Used by:
Cause: A lead on the left side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A89??
Display:
Used by:
Cause: A lead on the left side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A8A??
Display:
Used by:
Cause: A lead on the lower side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A8B??
Display:
Used by:
Cause: A lead on the lower side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A8C??
Display:
Used by:
Cause: A lead on the right side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A8D??
Display:
Used by:
Cause: A lead on the right side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A8E??
Display:
Used by:
Cause: A lead on the upper side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0A8F??
Display:
Used by:
Cause: A lead on the upper side of the part is too short. The final two digits indicate the lead number.
第 1332 页