FUJI错误代码查询.pdf - 第2228页

Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the production program. ------------------------------ Code: 51??1409 Display: Format error in B mark's &q…

100%1 / 5282
mark was not found. This report is made when the mark data and production program are in the same
file, the G mark data is required in the applicable machine type and the above error is detected. When
downloading, the G mark data is set to its default values.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the production program.
------------------------------
Code: 51??1404
Display: "UNIT", "MARK" - "BLOCK", "MARKDT-" for F mark is multiply defined.
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and "BLOCK", "MARKDT" for the F
mark was multiply defined. This report is made when the mark data and production program are in the
same file and the above error is detected. When downloading, the first "BLOCK", "MARKDT-" to appear is
taken as the valid one.
Remedy: At the "MARKTYPE" setting in "UNIT", "MARK" - "BLOCK", "HEADER-" in the production
program, check that the F mark is not multiply defined.
------------------------------
Code: 51??1405
Display: "UNIT", "MARK" - "BLOCK", "MARKDT-" for B mark is multiply defined.
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and "BLOCK", "MARKDT" for the B
mark was multiply defined. This report is made when the mark data and production program are in the
same file and the above error is detected. When downloading, the first "BLOCK", "MARKDT-" to appear is
taken as the valid one.
Remedy: At the "MARKTYPE" setting in "UNIT", "MARK" - "BLOCK", "HEADER-" in the production
program, check that the B mark is not multiply defined.
------------------------------
Code: 51??1406
Display: "UNIT", "MARK" - "BLOCK", "MARKDT-" for M mark is multiply defined.
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and "BLOCK", "MARKDT" for the M
mark was multiply defined. This report is made when the mark data and production program are in the
same file and the above error is detected. When downloading, the first "BLOCK", "MARKDT-" to appear is
taken as the valid one.
Remedy: At the "MARKTYPE" setting in "UNIT", "MARK" - "BLOCK", "HEADER-" in the production
program, check that the M mark is not multiply defined.
------------------------------
Code: 51??1407
Display: "UNIT", "MARK" - "BLOCK", "MARKDT-" for G mark is multiply defined.
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and "BLOCK", "MARKDT" for the G
mark was multiply defined. This report is made when the mark data and production program are in the
same file and the above error is detected. When downloading, the first "BLOCK", "MARKDT-" to appear is
taken as the valid one.
Remedy: At the "MARKTYPE" setting in "UNIT", "MARK" - "BLOCK", "HEADER-" in the production
program, check that the G mark is not multiply defined.
------------------------------
Code: 51??1408
Display: Format error in F mark's "UNIT", "MARK" - "BLOCK", "MARKDT-".
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and a format error was detected in
F mark's "BLOCK", "MARKDT-". This report is made when the mark data and production program are in
the same file and the above error is detected.
第 2227 页
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the production program.
------------------------------
Code: 51??1409
Display: Format error in B mark's "UNIT", "MARK" - "BLOCK" MARKDT-".
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and a format error was detected in
B mark's "BLOCK", "MARKDT-". This report is made when the mark data and production program are in
the same file and the above error is detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the production program.
------------------------------
Code: 51??1410
Display: Format error in M mark's "UNIT", "MARK" - "BLOCK", "MARKDT-".
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and a format error was detected in
M mark's "BLOCK", "MARKDT-". This report is made when the mark data and production program are in
the same file and the above error is detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the production program.
------------------------------
Code: 51??1411
Display: Format error in G mark's "UNIT", "MARK" - "BLOCK", "MARKDT-".
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and a format error was detected in
G mark's "BLOCK", "MARKDT-". This report is made when the mark data and production program are in
the same file and the above error is detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the production program.
------------------------------
Code: 51??1500
Display: No nozzle data file.
Used by:
Cause: The nozzle data file referred to in the specified production program was not found. This report is
made when the nozzle data and the production program are in different files, the nozzle data being
referred to is required in the applicable machine type and the above error is detected.
Remedy: Check the setting for "GNAN" in "BLOCK", "PGHEAD" in the production program. Furthermore,
check that the file is in the nozzle data directory.
------------------------------
Code: 51??1501
Display: Nozzle data file in use.
Used by:
Cause: The nozzle data file referred to in the specified production program is being used. This report is
made when the nozzle data and the production program are in different files, the nozzle data being
referred to is required in the applicable machine type and the above error is detected.
Remedy: Wait until the file is not being used and then re-execute.
------------------------------
Code: 51??1502
Display: No authorization for nozzle data file.
Used by:
Cause: There is no access authorization for the nozzle data file which is referred to in the specified
production program. This report is made when the nozzle data and the production program are in
different files, the nozzle data being referred to is required in the applicable machine type and the above
error is detected.
Remedy:
第 2228 页
------------------------------
Code: 51??1503
Display: Nozzle data file cannot be opened.
Used by:
Cause: The nozzle data file referred to in the specified production program cannot be opened. This report
is made when the nozzle data and the production program are in different files, the nozzle data being
referred to is required in the applicable machine type and the above error is detected.
Remedy:
------------------------------
Code: 51??1504
Display: No "UNIT", "STRUCT" in nozzle data file.
Used by:
Cause: There is no "UNIT", "STRUCT" in the nozzle data file referred to in the specified production
program. This report is made when the nozzle data and the production program are in different files, the
nozzle data being referred to is required in the applicable machine type and the above error is detected.
Remedy: Check the settings for "UNIT", "STRUCT" in the nozzle data file which is referred to in the
production program.
------------------------------
Code: 51??1505
Display: Nozzle data file structure error.
Used by:
Cause: A format error was detected in "UNIT", "STRUCT" in the nozzle data file referred to in the
production program. This report is made when the nozzle data and the production program are in
different files, the nozzle data being referred to is required in the applicable machine type and the above
error is detected.
Remedy: Check the settings for "UNIT", "STRUCT" in the nozzle data file which is referred to in the
production program.
------------------------------
Code: 51??1506
Display: Not a nozzle data file.
Used by:
Cause: The nozzle data file which is referred to in the specified production program is not nozzle data.
This report is made when the nozzle data and the production program are in different files, the nozzle data
being referred to is required in the applicable machine type and the above error is detected.
Remedy: Check the setting for "FILETYPE", "FILESTRUCT" in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in
the nozzle data file which is referred to in the production program.
------------------------------
Code: 51??1507
Display: Nozzle file read error.
Used by:
Cause: An error occurred when the nozzle data file referred to in the specified production program was
read. This report is made when the nozzle data and the production program are in different files and the
above error is detected.
Remedy: Check the nozzle data file which is referred to in the production program.
------------------------------
Code: 51??1510
Display: "FILETYPE" not entered in the nozzle data file.
Used by:
Cause: There is no entry for "FILETYPE" in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified
nozzle data file.
Remedy: "FILETYPE" is a mandatory item.