FUJI错误代码查询.pdf - 第453页
Display: Used by: IP1,IP2,IP3 Cause: Error due to lack of data. L3 attempted to make a calculation but was unable to do so due to a lack of data. The most common problems are that (a) not all the leads were measurable, (…
Cause: Axis number 15 - soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035F07
Display:
Used by: IP3
Cause: Axis number 15 not ready.
Remedy: Turn off the machine power.
------------------------------
Code: 12035F08
Display:
Used by:
Cause: Axis number 15 emergency stop.
Remedy: Turn off the machine power.
------------------------------
Code: 12035F09
Display:
Used by: IP3
Cause: Incorrect parameter was sent from axis number 15.
Remedy: Turn off the machine power.
------------------------------
Code: 12035F0A
Display:
Used by: IP3
Cause: Axis number 15 encoder error.
Remedy: Turn off the machine power.
------------------------------
Code: 12035F0B
Display:
Used by:
Cause: Axis number 15 synchronicity error.
Remedy: Cut the machine power.
------------------------------
Code: 12035F0C
Display:
Used by:
Cause: The servo interlock was activated during startup.
Remedy: Check the interlock sensor.
------------------------------
Code: 12036001
Display:
Used by: IP1,IP2,IP3
Cause: This is a command sequence error. An L3 command could not be executed.
Remedy: The cause is probably a bug in the FIP-II firmware. Cut the power and restart the operation
from the beginning. If serial communication can be downloaded from the LLL board, the LLL error
conditions can be checked. Set the LLL board so that serial communication can be performed. If the LLL
board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and a
terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match the
LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036002
第 452 页
Display:
Used by: IP1,IP2,IP3
Cause: Error due to lack of data. L3 attempted to make a calculation but was unable to do so due to a
lack of data.
The most common problems are that
(a) not all the leads were measurable,
(b) the encoder pulse was not received from the encoder cable,
(c) coplanarity calculation was attempted after onley one side was measured.
Remedy: (a) If not all leads were measurable, check that the lead lengths set in Part data (Vision data
items 10.Lead_length_x, 11.Lead_length_y) are as accurate as possible.
(b) If the encoder pulse was not received from the encoder cable, check the encoder cable.
(c) If the coplanarity check can do checks for SOIC or QFP parts, the calculation can only be made after at
least two scans.
------------------------------
Code: 12036003
Display:
Used by: IP1,IP2,IP3
Cause: Parameter error. Invalid data was transmitted to the L3.
Remedy: Check the data under the Coplanarity heading in Part data. If serial communication can be
downloaded from the LLL board, the LLL error conditions can be checked. Set the LLL board so that serial
communication can be performed. If the LLL board's dip switch S4's 1 is set to ON, debug information can
be output. Connect the LLL board and a terminal (personal computer, etc.) via an RS232C or RS-422
cable. The terminal settings must match the LLL board settings. In this way, if the LLL operates, one can
check where the error originated.
------------------------------
Code: 12036004
Display:
Used by: IP1,IP2,IP3
Cause: Incorrect command. An invalid command was sent to the L3.
Remedy: Perform reset-start. If serial communication can be downloaded from the LLL board, the LLL
error conditions can be checked. Set the LLL board so that serial communication can be performed. If the
LLL board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and
a terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match
the LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036020
Display: Sensor 0 EEPROM Readback Error
Used by: IP1,IP2,IP3
Cause: Communication could not be performed with L3 Sensor 0.
Remedy: Either the sensor cable is cut or is not connected. Check the sensor cable connection or
exchange the cable. If serial communication can be downloaded from the LLL board, the LLL error
conditions can be checked. Set the LLL board so that serial communication can be performed. If the LLL
board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and a
terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match the
LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036021
Display: Sensor 1 EEPROM Readback Error
Used by: IP1,IP2,IP3
Cause: Communication could not be performed with L3 Sensor 1.
Remedy: Either the sensor cable is cut or is not connected. Check the sensor cable connection or
第 453 页
exchange the cable. If serial communication can be downloaded from the LLL board, the LLL error
conditions can be checked. Set the LLL board so that serial communication can be performed. If the LLL
board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and a
terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match the
LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036022
Display: Sensor 0 Synchronization Error
Used by: IP1,IP2,IP3
Cause: Communication could not be performed with L3 Sensor 0.
Remedy: Either the sensor cable is cut or is not connected. Check the sensor cable connection or
exchange the cable. If serial communication can be downloaded from the LLL board, the LLL error
conditions can be checked. Set the LLL board so that serial communication can be performed. If the LLL
board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and a
terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match the
LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036023
Display: Sensor 1 Synchronization Error
Used by: IP1,IP2,IP3
Cause: Communication could not be performed with L3 Sensor 1.
Remedy: Either the sensor cable is cut or is not connected. Check the sensor cable connection or
exchange the cable. If serial communication can be downloaded from the LLL board, the LLL error
conditions can be checked. Set the LLL board so that serial communication can be performed. If the LLL
board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and a
terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match the
LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036030
Display: Expecting FIFO Data Empty
Used by: IP1,IP2,IP3
Cause: There is a defective VME board.
Remedy: Reset-start the machine. If serial communication can be downloaded from the LLL board, the
LLL error conditions can be checked. Set the LLL board so that serial communication can be performed.
If the LLL board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board
and a terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must
match the LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036031
Display: Expecting FIFO Data Available
Used by: IP1,IP2,IP3
Cause: There is a defective VME board.
Remedy: Reset-start the machine. If serial communication can be downloaded from the LLL board, the
LLL error conditions can be checked. Set the LLL board so that serial communication can be performed.
If the LLL board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board
and a terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must
match the LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036040
Display: Expecting Beam Blocked
Used by: IP1,IP2,IP3
第 454 页