FUJI错误代码查询.pdf - 第1964页

Cause: The base program filename is too long. Remedy: Check the filename. ------------------------------ Code: 21007743 Display: Illegal format at Machine type table Used by: Cause: The machine type table format is illeg…

100%1 / 5282
Code: 2100773A
Display: Not get Occupancy data
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 2100773B
Display: Not get Slot info data
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 2100773C
Display: New production file has no sequence
Used by:
Cause: There are no sequences in the new program file.
Remedy: Check the input file.
------------------------------
Code: 2100773D
Display: Parts height regulation over
Used by:
Cause: The part height exceeds the set limit.
Remedy: Check the Part data part height.
------------------------------
Code: 2100773E
Display: Different cartridge name in PST file
Used by:
Cause: The feeder name in the PST file is wrong.
Remedy: Check the PST file feeder name.
------------------------------
Code: 2100773F
Display: Input program file name is too long
Used by:
Cause: The input program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007740
Display: Output program file name is too long
Used by:
Cause: The output program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007741
Display: Permanent Set Table name is too long
Used by:
Cause: The Permanent Set Table name is too long.
Remedy: Check the filename.
------------------------------
Code: 21007742
Display: Base program file name is too long
Used by:
第 1963 页
Cause: The base program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007743
Display: Illegal format at Machine type table
Used by:
Cause: The machine type table format is illegal.
Remedy: Re-install the software.
------------------------------
Code: 21007744
Display: Make not mount sequence
Used by:
Cause: The queue data used in the strategy section of the system file could not be created.
Remedy: Re-boot MCS. If the error recurs, replace the MPU (memory) board.
------------------------------
Code: 21007745
Display: No entry Machine name
Used by:
Cause: The machine entered in the "Type" heading in "Sep_data" could not be found.
Remedy: Input the correct machine name under the "Type" (do not forget to also input "Time" and
"Device_Name") heading.
------------------------------
Code: 21007746
Display: Cam_table file open error
Used by:
Cause: The system file could not be opened.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 21007747
Display: Cam_table file read error
Used by:
Cause: The system file could not be read.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 21007748
Display: Cam_table file seek error
Used by:
Cause: The seek function did not work on the system file.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 21007749
Display: Cam_table file path read error
Used by:
Cause: The input path could not be specified.
Remedy: Re-boot MCS. If the error recurs, re-install the software.
------------------------------
Code: 2100774A
Display: Not get cycle time
Used by:
Cause: Management time could not be calculated.
Remedy: Re-install the Automatic Programming software.
第 1964 页
------------------------------
Code: 2100774B
Display: Illegal format at Cam_table
Used by:
Cause: The cam table is not formatted correctly.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100774C
Display: Pairing pattern file open error
Used by:
Cause: The system file could not be opened.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100774D
Display: Pairing pattern file read error
Used by:
Cause: The system file could not be read.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100774E
Display: Pairing pattern file file value different
Used by:
Cause: The contents of the system file are not normal.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100774F
Display: Not get queue position
Used by:
Cause: Memory could not be processed.
Remedy: Re-boot MCS.
------------------------------
Code: 21007750
Display: Sequence data co-ordinates over range
Used by:
Cause: There was a memory management error.
Remedy: Re-boot MCS. If the problem recurs, re-install the software.
------------------------------
Code: 21007751
Display: Sequence data co-ordinates over range
Used by:
Cause: The coordinates in the sequence data are outside the board range.
Remedy: Check that the correct values are input in XA, YA, Pcb_x and Pcb_y in the production program.
Check that the correct values are input in Pcb_org in the environment file. Pcb_org=x,y, board orientation
and change flag should be checked. The check flag could be either 0 or 1.
------------------------------
Code: 21007752
Display:
Used by:
Cause: The environment file could not be opened.
Remedy: Re-install the software.
------------------------------
第 1965 页