FUJI错误代码查询.pdf - 第141页
Display: 11022300 Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,IP3,QP132 Cause: The data does not match machine specifications (FCP5, FCP6, FCP6-5, FCP6-M). Remedy: Check the Proper data and transmit again. 1. Print out…
Remedy: Check the setting for Language in the Proper data at the MCS, and retransmit the Proper data.
Select either English, French, or Japanese. As French is currently not supported, English will display if
French is selected.
------------------------------
Code: 11022002
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6N,CP65,CP652C,CP642,CP643,IP2,IP3
Cause: The Proper "Device Check Port" is out of range.
Remedy: Check Proper data's "Device Check Port." When using the optional Handy Terminal this must be
set. Normally, to avoid communication board jumper setting problems, this is set to "1." This is the first
connector from the top of the board. This is set before the machine is delivered.
------------------------------
Code: 11022003
Display:
Used by: IP3
Cause: Device check terminal (ex.: Handy Terminal) communication port has been previously specified
elsewhere.
Remedy: Specify the correct value in Proper data's 73.Device Check port.
------------------------------
Code: 11022004
Display:
Used by: IP3,QP132
Cause: Verifier tool is not set correctly.
Remedy: Specify the correct value in Proper data's 71.Verifier Tool.
------------------------------
Code: 11022005
Display:
Used by: IP3,QP132
Cause: The device check is specified to operate but the device check terminal is set to not operate, and
both ESC Permission and MAN Permission are set to "Non."
Remedy: If the device check is specified to operate but the device check terminal is set to not operate,
either 74.ESC Permission or 75.MAN Permission must be set to "Permit." Alternately, specify that the
device check not be used, or specify that a device check terminal be used.
------------------------------
Code: 11022006
Display: 11022006
Used by: GSP5
Cause: The Proper data cannot be transmitted because the MCS version is old.
Remedy: The machine software version has been upgraded to include additions to the Proper data and
therefore it is not compatible with the present version of MCS. Upgrade the MCS software. As a
temporary measure, return the machine to the original software version until the upgraded version of MCS
is received.
------------------------------
Code: 11022007
Display: Same as code.
Used by: SECS/GEM
Cause: The bit setting in "Machine_status A" (fourth bit from the right) which enables remote commands
is set to "0" or the value for the item "LMS_flag" is set to "0".
Remedy: Ensure that both of these are set to "1" when using SECS/GEM.
------------------------------
Code: 11022300
第 140 页
Display: 11022300
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,IP3,QP132
Cause: The data does not match machine specifications (FCP5, FCP6, FCP6-5, FCP6-M).
Remedy: Check the Proper data and transmit again.
1. Print out the Proper data, and after inputting new Proper data, transmit it to the machine.
2. Check that the machines registered in the MCS line descriptor are correct.
3. Check that the channel to which the data line cable is connected is correct.
------------------------------
Code: 11022321
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: X0, Y0 out of range (less than or equal to zero).
Remedy: Check X0, Y0 in Proper data.
------------------------------
Code: 11022322
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: XL, YL data out of range (<=0).
Remedy: Check XL, YL in Proper data.
------------------------------
Code: 11022323
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: cam_speed out of range (<=100 or >=1706).
Remedy: Check cam_speed in Proper data.
------------------------------
Code: 11022324
Display:
Used by: CP3
Cause: Q_data out of range (<-1 or >=3600).
Remedy: Check Q_data in Proper data.
------------------------------
Code: 11022325
Display:
Used by: CP3
Cause: R_data out of range (<-1 or >=3600).
Remedy: Check R_data in Proper data.
------------------------------
Code: 11022326
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: dl_position out of range (<-1 or >=3600).
Remedy: Check dl_position in Proper data.
------------------------------
Code: 11022327
Display:
Used by: CP3
Cause: ccd_x or ccd_y is 0.
Remedy: Check ccd_x and ccd_y in Proper data.
------------------------------
Code: 11022328
第 141 页
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: d_org_r out of range (<-41000 or >53000).
Remedy: Check d_org_r in Proper data.
------------------------------
Code: 11022329
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: d_org_l out of range (<-2000 or >-1).
Remedy: Check d_org_l in Proper data.
------------------------------
Code: 1102232A
Display:
Used by: CP3
Cause: nozzle_s, nozzle_l out of range (<8000 or >5000).
Remedy: Check "nozzle_s," "nozzle_l" in Proper data.
------------------------------
Code: 1102232B
Display:
Used by: CP3
Cause: chuck_center_x or chuck_X_small No.1 is less than 4000.
Remedy: Check chuck_center_x at Proper data and retransmit it to the machine, or use the command
keys [SET], [PROPER] and [CENTER] to automatically reset the Proper data.
------------------------------
Code: 1102232C
Display:
Used by: CP3
Cause: chuck_center_y is 0.
Remedy: Check chuck_center_y in Proper data and re-transmit to the machine.
------------------------------
Code: 1102232D
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The PCB check positions have been incorrectly entered.
Remedy: Set PCB CHECK POSITION X, PCB_CHECK_POSITION_Y to 0 (CP4).
------------------------------
Code: 1102232E
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Values have not been entered for Proper data items Max Limit Position X and Min Limit Position
X (CP4).
Remedy: Set Proper data items Max Limit Position X and Min Limit Position X to 0.
------------------------------
Code: 1102232F
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Values have not been entered for Proper data items Max Limit Position Y and Min Limit Position Y
(CP4).
Remedy: Set Proper data items Max Limit Position Y and Min Limit Position Y to 0.
------------------------------
Code: 11022330