FUJI错误代码查询.pdf - 第654页
Used by: QP132 Cause: There is no space in the internal table used for managing the board information of boards inside the pallet. This is ordinarily an QP132 software bug. Remedy: First confirm whether or not the pallet…
information was being determined from the number and sizes of boards in the pallet.
Remedy: Given this status, production cannot be interrupted when there is a pallet at the pallet setup
station (mark read station). After unloading all boards inside the machine using the flush out operation,
then restart normal operation.
------------------------------
Code: 12066808
Display: DATA LOGIC ERROR [12066808]
Used by: QP132
Cause: (Reserved)
Remedy:
------------------------------
Code: 12066809
Display: DATA LOGIC ERROR [12066809]
Used by: QP132
Cause: No database can be found for the pallet number reported by the PMC or the Approach Station.
This error will occur when production is recommenced when the flush out process is not fully complete, or
when a damaged part is replaced without first replacing the ID plate.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. Refer to the pallet ID list displayed using the [Pallet Skip]
command to confirm whether any pallets are using an identical ID. When replacing a damaged pallet,
remove the ID plate from the previous pallet and attach it to the new one.
It will not be possible to proceed with operation unless the error is cleared. If necessary restart normal
operation after unloading all boards inside the machine using the [Flush Out] command.
------------------------------
Code: 1206680A
Display: DATA LOGIC ERROR [1206680A]
Used by: QP132
Cause: The status issued from the PMC during automatic operation was "0". Automatic production on
the QP1 determines the production part according to the status report issued from the PMC. This error
should not occur according to logic and is being investigated as a reliability issue.
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause. If this problem occurs regularly,
output trace data from the machine and send it to Fuji for analysis.
------------------------------
Code: 1206680B
Display: DATA LOGIC ERROR [1206680B]
Used by: QP132
Cause: After automatic production is restarted, the program name stored for the pallet ID at the
approach station is different from the program name prior to restart.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206680C
Display: DATA LOGIC ERROR [1206680C]
第 653 页
Used by: QP132
Cause: There is no space in the internal table used for managing the board information of boards inside
the pallet. This is ordinarily an QP132 software bug.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206680D
Display: DATA LOGIC ERROR [1206680D]
Used by: QP132
Cause: There is a contradiction in the QP132 internal data between the pallet management table and the
board management table. A pallet indexing error will occur when either the pallet comes to a halt in the
incorrect position, or when erroneous data is reported by the PMC.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206680E
Display: DATA LOGIC ERROR [1206680E]
Used by: QP132
Cause: The PMC could not locate the program being used in production inside the machine. If the
program being used in production is not in the PMC, the PMC will send a request to the machine (main
controller). The QP132 specifications require that the program being used in production must be inside
the machine, therefore program deletion must not be carried out until the final board has been unloaded.
Remedy: Transmit the program.
------------------------------
Code: 1206680F
Display: DATA LOGIC ERROR [1206680F]
Used by: QP132
Cause: Multiple pallet ID number tables were detected in the pallet management table within the QP132
internal data. Either a pallet exists that actually has the same ID or there is a bug in the QP132 software.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. When replacing a damaged pallet, remove the ID plate from the
previous pallet and attach it to the new one. It will not be possible to proceed with operation unless the
error is cleared. If necessary restart normal operation after unloading all boards inside the machine using
the [Flush Out] command.
------------------------------
Code: 12066810
Display: DATA LOGIC ERROR [12066810]
Used by: QP132
Cause: The table for setting the amount of displacement for fiducial marks does not exist. On the
QP132, the board information is saved in the table when the board is loaded, and the pallet ID is saved at
the approach station after the board is loaded. As a result, when a board exists in the pallet loader after
第 654 页
being set using the I/O operation, the board information will be deleted if the reset-start operation is
carried out thereby making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066811
Display: DATA LOGIC ERROR [12066811]
Used by: QP132
Cause: The board information table inside the pallet does not exist. On the QP132, the board
information is saved in the table when the board is loaded, and the pallet ID is saved at the approach
station after the board is loaded. As a result, when a board exists in the pallet loader after being set using
the I/O commands, the board information will be deleted if the reset-start operation is carried out thereby
making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066812
Display: DATA LOGIC ERROR [12066812]
Used by: QP132
Cause: The creation of multiple board management tables in the QP132 internal data was detected. This
error occurs when separate pallets are found to have the same ID, or there is a QP132 software bug.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066813
Display: DATA LOGIC ERROR [12066813]
Used by: QP132
Cause: During operation in the "One board per pallet" mode a pallet with multiple boards was detected.
This is a bug in the QP132 software.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066814
Display: DATA LOGIC ERROR [12066814]
Used by: QP132
第 655 页