FUJI错误代码查询.pdf - 第143页

Display: Used by: Cause: Values have not been entered for Proper data items Max Limit Position D and Min Limit Position D (CP4). Remedy: Set Proper data items Max Limit Position D and Min Limit Position D to 0. ---------…

100%1 / 5282
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: d_org_r out of range (<-41000 or >53000).
Remedy: Check d_org_r in Proper data.
------------------------------
Code: 11022329
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: d_org_l out of range (<-2000 or >-1).
Remedy: Check d_org_l in Proper data.
------------------------------
Code: 1102232A
Display:
Used by: CP3
Cause: nozzle_s, nozzle_l out of range (<8000 or >5000).
Remedy: Check "nozzle_s," "nozzle_l" in Proper data.
------------------------------
Code: 1102232B
Display:
Used by: CP3
Cause: chuck_center_x or chuck_X_small No.1 is less than 4000.
Remedy: Check chuck_center_x at Proper data and retransmit it to the machine, or use the command
keys [SET], [PROPER] and [CENTER] to automatically reset the Proper data.
------------------------------
Code: 1102232C
Display:
Used by: CP3
Cause: chuck_center_y is 0.
Remedy: Check chuck_center_y in Proper data and re-transmit to the machine.
------------------------------
Code: 1102232D
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The PCB check positions have been incorrectly entered.
Remedy: Set PCB CHECK POSITION X, PCB_CHECK_POSITION_Y to 0 (CP4).
------------------------------
Code: 1102232E
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Values have not been entered for Proper data items Max Limit Position X and Min Limit Position
X (CP4).
Remedy: Set Proper data items Max Limit Position X and Min Limit Position X to 0.
------------------------------
Code: 1102232F
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Values have not been entered for Proper data items Max Limit Position Y and Min Limit Position Y
(CP4).
Remedy: Set Proper data items Max Limit Position Y and Min Limit Position Y to 0.
------------------------------
Code: 11022330
第 142 页
Display:
Used by:
Cause: Values have not been entered for Proper data items Max Limit Position D and Min Limit Position
D (CP4).
Remedy: Set Proper data items Max Limit Position D and Min Limit Position D to 0.
------------------------------
Code: 11022331
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Values have not been entered for Proper data items Max Limit Position Z and Min Limit Position Z
(CP4).
Remedy: Set Proper data items Max Limit Position Z and Min Limit Position Z to 0.
------------------------------
Code: 11022332
Display:
Used by: CP4-1,CP4-2,CP4-3
Cause: The Proper data item S (A~L) Place Offset X value is inappropriate (CP4).
Remedy: Set Proper data item S (A~L) Place Offset X between -2000 and 2000 (CP4).
------------------------------
Code: 11022333
Display:
Used by: CP4-1,CP4-2,CP4-3
Cause: The Proper data item M (A~L) Place Offset X value is inappropriate (CP4).
Remedy: Set Proper data item M (A~L) Place Offset X between -2000 and 2000 (CP4).
------------------------------
Code: 11022334
Display:
Used by: CP4-1,CP4-2,CP4-3
Cause: The Proper data item L (A~L) Place Offset X value is inappropriate (CP4).
Remedy: Set Proper data item L (A~L) Place Offset X between -2000 and 2000 (CP4).
------------------------------
Code: 11022335
Display:
Used by: CP4-1,CP4-2,CP4-3
Cause: The Proper data item S (A~L) Place Offset Y value is inappropriate (CP4).
Remedy: Set Proper data item S (A~L) Place Offset Y between -2000 and 2000 (CP4).
------------------------------
Code: 11022336
Display:
Used by: CP4-1,CP4-2,CP4-3
Cause: The Proper data item M (A~L) Place Offset Y value is inappropriate (CP4).
Remedy: Set Proper data item M (A~L) Place Offset Y between -2000 and 2000 (CP4).
------------------------------
Code: 11022337
Display:
Used by: CP4-1,CP4-2,CP4-3
Cause: The Proper data item L (A~L) Place Offset Y value is inappropriate (CP4).
Remedy: Set Proper data item L (A~L) Place Offset Y between -2000 and 2000 (CP4).
------------------------------
Code: 11022338
Display:
第 143 页
Used by: CP4-1,CP4-2,CP4-3
Cause: The fine theta axis angle of rotation is greater than the limit set in Proper data.(CP4-1,CP4-2) The
results of component vision processing indicate a compensation amount exceeding 30 mm in the Q
direction.(CP4-3)
Remedy: Check the manner in which the component is picked up, and make sure that the device offset
value is appropriate.(CP4-1,CP4-2,CP4-3) Alternately, set the Proper data item q_correct_limit to a larger
value. Default is 30000 (set in increments of 1/1000 degree).(CP4-1,CP4-2)
------------------------------
Code: 11022339
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Max Limit Position T1 and Min Limit Position T1 have no values entered.
Remedy: Measure these values (refer to the Proper data measurement manual) and input appropriate
values in Proper data.
------------------------------
Code: 1102233A
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Max Limit Position T2 and Min Limit Position T2 have no values entered.
Remedy: Measure these values (refer to the Proper data measurement manual) and input appropriate
values in Proper data.
------------------------------
Code: 1102233B
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: An appropriate value for Proper data's Pickup Position for device table 2 has not been entered.
Remedy: Measure this value (refer to the Proper data measurement manual) and input appropriate values
in Proper data.
------------------------------
Code: 1102233C
Display: 1102233C
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The nozzle place offset X is unsuitable (CP6).
Remedy: The nozzle place offset X is set to less than -2000 or more than 2000. Enter an appropriate
value.
------------------------------
Code: 1102233D
Display: 1102233D
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The nozzle place offset Y is unsuitable (CP6).
Remedy: The nozzle place offset Y is set to less than -2000 or more than 2000. Enter an appropriate
value.
------------------------------
Code: 1102233E
Display: 1102233E
Used by: CP6,CP6M,CP65,CP652C,CP642
Cause: The machine size setting in Proper data is incorrect (FCP6).
Remedy: Set the Proper data item 141.M/C Size 4000 5000 to 4000 for a type 4000 machine and 5000 for
a type 5000 machine.
------------------------------
Code: 1102233F
第 144 页