Cause: There was too much picking slippage in the Y direction. Remedy: Check the part feeding orientation. ------------------------------ Code: 1D21E??? Display: Used by: Cause: The image in vision processing is not corr…
Used by:
Cause: A lead could not be detected on the right side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D21C3??
Display:
Used by:
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D21C4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D21C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D21C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D21C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D21D000
Display:
Used by:
Cause: There was too much picking slippage in the X direction.
Remedy: Check the part feeding orientation.
------------------------------
Code: 1D21D080
Display:
Used by:
第 1545 页
Cause: There was too much picking slippage in the Y direction.
Remedy: Check the part feeding orientation.
------------------------------
Code: 1D21E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D21F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D230001
Display:
Used by:
Cause: Part data is set incorrectly.
Remedy: Set Part data correctly.
------------------------------
Code: 1D230002
Display:
Used by:
Cause: There are no parts.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D230003
Display:
Used by:
Cause: Unable to find the left and right edges.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D230004
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the camera, vision processing board, cable and focus. Make sure foreign matter is not
stuck to the parts.
------------------------------
Code: 1D230005
Display:
Used by:
Cause: The X axis orientation is too long. The value obtained when measuring from the ends of 2 leads
on the left and right is more than 20% larger than the value entered in Part data.
Remedy: Check the length of the part.
------------------------------
Code: 1D230006
第 1546 页
Display:
Used by:
Cause: The length of the X axis is too short.
Remedy: Check the X length of the part.
------------------------------
Code: 1D230007
Display: 1D230007(CP2,3)
Used by:
Cause: The length in the y direction is too long. The length is more than 50% longer than the input
value.
Remedy: Check the length of the part.
------------------------------
Code: 1D230008
Display: 1D230008(CP2,3)
Used by:
Cause: The length in the y direction is too short. The length is more than 50% shorter than the input
value.
Remedy: Check the length of the part.
------------------------------
Code: 1D230010
Display: 1D230010(CP2,3)
Used by:
Cause: The leads are too long.
Remedy: Check the lead length.
------------------------------
Code: 1D230018
Display: 1D230018(CP2,3)
Used by:
Cause: The lead width is more than 50% wider than the input value.
Remedy: Check the lead width.
------------------------------
Code: 1D230019
Display: 1D230019(CP2,3)
Used by:
Cause: The lead width is more than 50% narrower than the input value.
Remedy: Check the lead width.
------------------------------
Code: 1D234001
Display: 1D234001
Used by:
Cause: This is a part data error.
Remedy: Check that the part data is correct.
------------------------------
Code: 1D234002
Display: 1D234002
Used by:
Cause: There are no parts.
Remedy: Check the camera, the camera focus, the vision processing board and the cables. Remove any
foreign objects which may be present.
------------------------------
Code: 1D234003