FUJI错误代码查询.pdf - 第660页

Code: 1206690D Display: PFU Unclamp Error [1206690D] Used by: QP132 Cause: The PFU's unclamping operation (X035-X03B: PFU? UNCLP) did not finish in the given time. Remedy: Check operation using I/O commands and adju…

100%1 / 5282
Code: 12066905
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066906
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066907
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066908
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066909
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 1206690A
Display: Parts supply unit error.
Used by: NP2,QP3
Cause: Parts supply unit error.
Remedy: If the parts supply unit is in position at the removable supply side of the machine, select the
[Power On] and [Power Off] commands on the [Parts Stage] screen, and then select the [Confirmation]
command. If the parts supply unit is not attached, set it in position at the machine. For the fixed supply
side, reboot the machine.
------------------------------
Code: 1206690B
Display: PFU Clamp Error [1206690B]
Used by: QP132
Cause: During automatic operation, the PFU's X030-X033: PFU? CLP OK turned OFF
Remedy: Check that the PFU settings are correct.
------------------------------
Code: 1206690C
Display: PFU Clamp Error [1206690C]
Used by: QP132
Cause: The PFU's clamping operation (X034-X03A: PFU? CLP) did not finish in the given time.
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
第 659 页
Code: 1206690D
Display: PFU Unclamp Error [1206690D]
Used by: QP132
Cause: The PFU's unclamping operation (X035-X03B: PFU? UNCLP) did not finish in the given time.
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 12066A00
Display: ID_GET_PAGE_ERR
LD_ERR 12066A00
Used by: QP132
Cause: The data carrier page data could not be read.
Remedy: Make sure that circulation has been carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A01
Display: ID_TRN_MDL_ERR
LD_ERR 12066A01
Used by: QP132
Cause: There was a communication failure with the command that controls the number of write times.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A02
Display: ID_PAGE_OVER_ERR
LD_ERR 12066A02
Used by:
Cause: The number of data carrier write times has been exceeded.
Remedy: Replace the pallet data carrier.
------------------------------
Code: 12066A03
Display: ID_MDL_RESP_ERR
LD_ERR 12066A03
Used by: QP132
Cause: There was an error with the response from the command that controls the number of write times.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A04
Display: ID_READ_DATA_ERR
LD_ERR 12066A04
Used by: QP132
Cause: The first page of data of the data carrier could not be read.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A05
Display: ID_COPY_DATA_ERR
第 660 页
LD_ERR 12066A05
Used by: QP132
Cause: There was a failure with the data carrier page toggle write function.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A06
Display: ID_NEXT_PAGE_ERR
LD_ERR 12066A06
Used by: QP132
Cause: There was a failure with the page data write function.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A07
Display: CARRIER DATA ERROR
ID Reader Error: 12066A07
Used by: QP132
Cause: The pallet's carrier data at the landing station is corrupt.
Remedy: The pallet's data carrier at the landing station has corrupted information. Remove all pallets
and reload them.
------------------------------
Code: 12066A08
Display: No carrier at landing station.
ID Reader Error: 12066A08
Used by: QP132
Cause: A carrier is at the landing station when it should not be there or, when a carrier is expected for
the loading of a pallet, there is no carrier present.
Remedy: Check that the connection between the landing station head and ID controller, as well as the
connection between the ID controller and the machine data port, is good. When a pallet is present when
none should be, remove and reload all pallets.
------------------------------
Code: 12066A09
Display: JEDEC tray type error!
Used by: QP301
Cause: A JEDEC tray feeder of the wrong type has been attached.
Remedy: Attach a JEDEC tray feeder of the correct type.
------------------------------
Code: 12066A0A
Display: Lifter plate error!
Used by: QP301
Cause: An atempt was made to unclamp the package with the lifter plate in place.
Remedy: Remove the lifter plate.
------------------------------
Code: 12066A0B
Display: Nozzle Position Error
Used by: QP301
Cause: Nozzle is not set to the right holder.
Remedy: Check the nozzle positions and make changes as required.
第 661 页