FUJI错误代码查询.pdf - 第1503页
Remedy: Check how the parts are being supplied. ------------------------------ Code: 1D19E??? Display: Used by: Cause: The image in vision processing is not correct so operation was canceled. Remedy: Check the part. Chec…
Cause: A lead could not be detected on the right side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D19C3??
Display:
Used by:
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D19C4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D19C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D19C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D19C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D19D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D19D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
第 1502 页
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D19E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D19F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D1A0002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D1A4001
Display:
Used by:
Cause: This Vision number is unsupported.
Remedy: It is necessary to upgrade the software.
------------------------------
Code: 1D1A4003
Display:
Used by:
Cause: The part could not be detected.
Remedy: Check the image taken by vision processing.
------------------------------
Code: 1D1A4004
Display:
Used by:
Cause: The part could not be detected.
Remedy: Check the image taken by vision processing.
------------------------------
Code: 1D1A4005
Display:
Used by:
Cause: The size of the part in the X direction is too large.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D1A4006
Display:
Used by:
Cause: The size of the part in the X direction is too small.
Remedy: Check the part shape and the orientation of the part.
------------------------------
第 1503 页
Code: 1D1A4007
Display:
Used by:
Cause: The size of the part in the Y direction is too large.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D1A4008
Display:
Used by:
Cause: The size of the part in the Y direction is too small.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D1A8002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large.Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D1A8100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D1A8110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D1A8111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D1A8112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D1A8113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D1A8114
第 1504 页