Used by: Cause: The device size of the Device data is too small or too large for the field. Remedy: The data field cannot be edited at this point, so make sure it is correct beforehand. ------------------------------ Cod…
Code: 21005501
Display: Specified device number not found in device data.
Used by:
Cause: The device number does not exist.
Remedy: Change the device data and try again.
------------------------------
Code: 21005502
Display: Specified device number not found in sequence data.
Used by:
Cause: This is a warning.
Remedy: The specified device number was not found in sequence data. The sequence data accompanying
the specified device number does not exist.
------------------------------
Code: 21005503
Display: Working mode not 'D'
Used by:
Cause: The input device number was wrong.
Remedy: The input device number must have an accompanying sequence number.
------------------------------
Code: 21005507
Display: Change command device number not select
Used by:
Cause: Either the device number was not changed or not input.
Remedy: After inputting the data, select F6 [execute].
------------------------------
Code: 21005555
Display: This item is automatically set; no setting required.
Used by:
Cause: This item is automatically set. No setting is required.
Remedy: This is just a warning message. It is not an error.
------------------------------
Code: 21005600
Display: Data entry error. Please check (File descriptor MIN & MAX)
Used by:
Cause: When inputting a block of data, some input was out of range.
Remedy: Adjust the input data and re-input the data.
------------------------------
Code: 21005601
Display: Search data not found.
Used by:
Cause: The data does not exist.
Remedy: Edit the data and re-execute.
------------------------------
Code: 21005602
Display: Data type parameter not specified in srch/rpl command.
Used by:
Cause: The parameter when the direct command was input is wrong.
Remedy: Check the input parameter.
------------------------------
Code: 21005603
Display: Data type match not found.
第 1884 页
Used by:
Cause: The device size of the Device data is too small or too large for the field.
Remedy: The data field cannot be edited at this point, so make sure it is correct beforehand.
------------------------------
Code: 21005604
Display: Data type cannot accept characters.
Used by:
Cause: This data type only accepts numerical input.
Remedy: Input numerical data.
------------------------------
Code: 21005605
Display: can't execute Srch/rpl command
Used by:
Cause: This is a multiple-heading field. A batch input was attempted for a single data field.
Remedy: Select more than one data field with the cursor. Batch input can only be performed in multiple-
heading fields.
------------------------------
Code: 21005606
Display: Search data or replace data not specified.
Used by:
Cause: The address of the data has not been set.
Remedy: Specify the address of the data and re-execute.
------------------------------
Code: 21005700
Display: Copy line overflow
Used by:
Cause: In the editor there is a buffer, allowing the maximum number of lines to double. This buffer has
overflowed.
Remedy: Eliminate all unnecessary data.
------------------------------
Code: 21005701
Display: Paste buffer overflow - clear buffer? [y/n]
Used by:
Cause: Copy command overflow mode was executed over 100 times.
Remedy: Clear either the paste buffer or clear buffer or both.
------------------------------
Code: 21005702
Display: Single entry data. Function key not valid
Used by:
Cause: The function key used cannot handle multiple-entry data. The copy, delete and other such keys
can only handle single entry data.
Remedy: Input single entry data.
------------------------------
Code: 21005703
Display: Data field over
Used by:
Cause: The specified address is out of the data field.
Remedy: Check the input data.
------------------------------
Code: 21005704
Display: Data field no match
第 1885 页
Used by:
Cause: Either no data was entered into the paste buffer or the paste command tried put the data into a
different field.
Remedy: Data can only be pasted into the same field.
------------------------------
Code: 21005705
Display: Copy line is record field over
Used by:
Cause: The data exceeded the range of the field during copying. (Data is recorded up to the range of the
field.)
Remedy: Sufficient space is allowed for data so this problem should seldom occur. Field size cannot be
changed at this point, so make sure it is correct beforehand.
------------------------------
Code: 21005706
Display: Data entry error
Used by:
Cause: The data entry was out of range.
Remedy: Check the input data.
------------------------------
Code: 21005801
Display: Digitizer not found
Used by:
Cause: The digitizer is not registered in the line descriptor.
Remedy: Register the digitizer (Mc_type=18) in the editor (line descriptor) and re-boot the system. Refer to
the operation manual, Part 2, Sections 1,2 and 3 for details.
------------------------------
Code: 21005802
Display: Digitizer time out error
Used by:
Cause: Nothing was received from the digitizer within the specified time limit.
Remedy: Check that the cable and connector is properly connected. Perform the self-test on port RS
232C.
------------------------------
Code: 21005803
Display: Digitizer data error
Used by:
Cause: The data from the digitizer is out of range.
Remedy: Check the range of entry.
------------------------------
Code: 21005811
Display: file name error
Used by:
Cause: The filename is longer than 19 characters. This number includes appendages such as ".exp."
Remedy: Shorten it.
------------------------------
Code: 21005900
Display: Now editting data is not Programe data
Used by:
Cause: The cut command was used on data which was not in the production program or the source
program.
Remedy: Do not use the cut command on data which is not in the production program or source program.