robot safety sensor. ------------------------------ Code: 11081090 Display: TRAY SET OFF Used by: MTU4 Cause: The tray set check sensor was off while the T axis was moving (other than during inching). Remedy: Check that …

100%1 / 5282
MTU is of the type where air is supplied from the IP machine, check that the air pressure sensor is not
installed. In this case also check that the inputs for the air pressure sensor are short circuited.
------------------------------
Code: 11081080
Display: MTU not Zero set Properly
Used by: MTU4
Cause: An error occurred during zero setting.
Remedy: Check the T axis speed reduction sensor and the robot safety sensor.
------------------------------
Code: 11081081
Display: Part Carrier: Zero Setting Failed
Used by: MTU4
Cause: When the carrier retracted, the retract end sensor did not come on within the prescribed time.
Remedy: Adjust the carrier retract end sensor.
------------------------------
Code: 11081083
Display: Y Axis Deceleration Sensor is Not ON at Nozzle change
Used by: MTU4
Cause: The Y axis speed reduction sensor was not on when the nozzle was changed at zero setting.
Remedy: Adjust the Y axis speed reduction sensor and the dog.
------------------------------
Code: 11081084
Display: Z Axis Deceleration Sensor is Not ON at Nozzle change
Used by: MTU4
Cause: The Z axis speed reduction sensor was not on when the nozzle was changed at zero setting.
Remedy: Adjust the Z axis speed reduction sensor and the dog.
------------------------------
Code: 11081085
Display: Nozzle Changer is Not at Retract Limit Position
Used by: MTU4
Cause: The nozzle changer retract sensor was not on when the nozzle was changed at zero setting.
Remedy: Adjust the nozzle changer retract and advance sensors.
------------------------------
Code: 11081086
Display: Nozzle Pos. Sensor Error
Used by: MTU4
Cause: When the nozzle rotated during zero setting, the nozzle position sensors did not turn on at the
correct positions.
Remedy: Check the nozzle position sensors, the dogs and the nozzle changer.
------------------------------
Code: 11081087
Display: Tray Set Off at Zero Set
Used by: MTU4
Cause: During zero setting the tray set sensor was activated.
Remedy: Check that the trays are correctly set in place and that the tray door is closed.
------------------------------
Code: 11081088
Display: Y Axis Deceleration Sensor and Tray Space Chk Sensor is Not ON at Zero Set
Used by: MTU4
Cause: During zero setting neither the Y axis speed reduction sensor nor the robot safety sensor was on.
Remedy: After manually turning on the Y axis speed reduction sensor, inch the T axis and turn on the
第 214 页
robot safety sensor.
------------------------------
Code: 11081090
Display: TRAY SET OFF
Used by: MTU4
Cause: The tray set check sensor was off while the T axis was moving (other than during inching).
Remedy: Check that the tray plate is correctly positioned.
------------------------------
Code: 11081091
Display: Tray positioning sensor is not on.
Used by: MTU4
Details: The tray positioning sensor is not on.
Cause:
Remedy: Adjust the robot safety sensor.
------------------------------
Code: 11081092
Display: Tray positioning sensor is not off.
Used by: MTU4
Details: The tray positioning sensor is not off.
Cause:
Remedy: Adjust the robot safety sensor.
------------------------------
Code: 110810A0
Display: Software limit: Check +X
Used by:
Cause: During automatic operation, the X axis moved to a position (in the plus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A1
Display: Software limit: Check -X
Used by: MTU3,MTU4,MTU5
Cause: During automatic operation, the X axis moved to a position (in the minus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A2
Display: Software limit: Check +Y
Used by: MTU3,MTU4,MTU5
Cause: During automatic operation, the Y axis moved to a position (in the plus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A3
Display: Software limit: Check -Y
Used by: MTU3,MTU4,MTU5
Cause: During automatic operation, the Y axis moved to a position (in the minus direction) outside the
software limit set in Proper data.
第 215 页
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A4
Display: Software limit: Check +Z
Used by: MTU3,MTU4,MTU5
Cause: During automatic operation, the Z axis moved to a position (in the plus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A5
Display: Software limit: Check -Z
Used by: MTU3,MTU4,MTU5
Cause: During automatic operation, the Z axis moved to a position (in the minus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A6
Display: Software limit: Check +T
Used by: MTU4
Cause: During automatic operation, the T axis moved to a position (in the plus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A7
Display: Software limit: Check -T
Used by: MTU4
Cause: During automatic operation, the T axis moved to a position (in the minus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement and set correct data.
------------------------------
Code: 11081100
Display: 11081100
Used by: MTU3,MTU5
Cause: When the nozzle and the conveyor interfere with each other, the Z axis interlock sensor will be on
and the Y axis retract sensor off.
Remedy: Move the Y axis and Z axis away from the interference area.
------------------------------
Code: 11081120
Display: 11081120
Used by: MTU3,MTU5
Cause: The rear parts supply door was opened.
Remedy: Close the rear parts supply door.
------------------------------
Code: 11082000
Display: MTU is in ON_LINE Mode
Used by: MTU3,MTU4,MTU5
Cause: When the MTU was in the on-line mode, a command for off-line use was issued by the IP