FUJI错误代码查询.pdf - 第153页

2. Check that the machines registered in the MCS line descriptor are correct. 3. Check that the channel to which the data line cable is connected is correct. 4. If the machine is an IP-1 using MCS/1, input a number other…

100%1 / 5282
Used by: GSP5
Cause: The Proper Data item "186. Cleaner type" is not within specifications (GSP5).
Remedy: The Proper Data item "186. Cleaner type" should be set to "0" when the standard cleaner is
used. When the cleaning unit has been retrofitted, the last bit must be set to "1". Check the Proper Data
and that I/O input 1212 (optional board) CLEANER TYPE is on and then retransmit.
------------------------------
Code: 1102251F
Display: Same as code
Used by: GP551,GP6
Cause: The unloading timer setting is outside the valid range.
Remedy: Make sure that the "ssd_timer" parameter in the Proper data is set to a value from 0.1 to 60
[sec].
------------------------------
Code: 11022520
Display: Same as code
Used by: GP6
Cause: The solder supply speed specified in the Proper data is outside the valid range.
Remedy: Make sure that the "Solder_Supply_speed" parameter in the Proper data is set to a value from 0
to 200 [mm/sec].
------------------------------
Code: 11022521
Display: Same as code.
Used by: GP551
Cause: For machines equipped with double squeegees, double-sided cleaning cannot be performed
during automatic operation.
Remedy: At Proper data item "202. Cleaner type", specify only the lower cleaner for use during automatic
operation.
------------------------------
Code: 11022522
Display: Same as code.
Used by:
Cause: A cleaning action has been attempted on a machine that is not equipped with cleaners or, double-
sided cleaning has been attempted on a machine equipped only with a lower cleaner.
Remedy: Ensure that the settings in Proper data reflect machine configuration.
------------------------------
Code: 11022523
Display: Same as code.
Used by: GP551,GP6
Cause: Cleaning method is not specified or incorrect value has been entered.
Remedy: Ensure if "cleaning method no.0,1,2" in Proper Data satisfy the following requirements.
More than six characters.
Available characters; Y,N,E and C. Lower case characters are not available.
Terminate code "E" is used.
------------------------------
Code: 11022600
Display:
Used by: IP1,IP2
Cause: The data does not match machine specifications (IP, IP2).
Remedy: Check the Proper data to ensure that the Proper data in the file is the Proper data for the
machine.
1. Print out the Proper, and after inputting new Proper, transmit this to the machine.
第 152 页
2. Check that the machines registered in the MCS line descriptor are correct.
3. Check that the channel to which the data line cable is connected is correct.
4. If the machine is an IP-1 using MCS/1, input a number other than 0 into Proper data's "Identity" item.
------------------------------
Code: 11022601
Display: 11022601
Used by: IP2
Cause: The Proper data item Nozzle size LL is set to 0 (FIP2).The nozzle size item "Nozzle size LL" in
Proper data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022602
Display: 11022602
Used by: IP2
Cause: The Proper data item Nozzle size L is set to 0 (FIP2).The nozzle size item "Nozzle size L" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022603
Display: 11022603
Used by: IP2
Cause: The Proper data item Nozzle size M is set to 0 (FIP2).The nozzle size item "Nozzle size M" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022604
Display: 11022604
Used by: IP2
Cause: The Proper data item Nozzle size S is set to 0 (FIP2).The nozzle size item "Nozzle size S" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022605
Display:
Used by: IP2
Cause: The Proper data item ccd level is set to 0 (IP2).
Remedy: Re-measure the CCD level and re-transmit Proper data.
------------------------------
Code: 11022606
Display:
Used by: IP1,IP2
Cause: The Proper data item max.speed_? is out of range (IP1).
Remedy: Check the Proper data item max.speed_?. The acceptable range is from 0% to 100%. Re-
transmit after changing Proper data.
------------------------------
Code: 11022607
Display:
Used by: IP1,IP2
Cause: The Proper data item Middle_? is out of range (IP1).
Remedy: Check the Proper data item Middle_?. The acceptable range is from 5 pulses to 500 pulses. Re-
transmit after changing Proper data.
第 153 页
------------------------------
Code: 11022608
Display:
Used by: IP1,IP2
Cause: Reducing_time in Proper data is out of range.
Remedy: The range for Proper data's Reducing time is from 100 msec to 6000 msec. Check the entry and
retransmit Proper data.
------------------------------
Code: 11022609
Display:
Used by: IP2
Cause: X0 in Proper data (IP2) is 0 (zero).
Remedy: Input a correct Proper data value at X0 and retransmit Proper data.
------------------------------
Code: 1102260A
Display:
Used by: IP2
Cause: Y0 in Proper data (IP2) is 0 (zero).
Remedy: Input a correct Proper data value at Y0 and retransmit Proper data.
------------------------------
Code: 1102260B
Display:
Used by: IP2
Cause: Choose Z0, 1 and 2. This is for IP2 machines with a Z axis.
Remedy: Enter the correct values and re-transmit Proper data.
------------------------------
Code: 1102260C
Display:
Used by: IP2
Cause: X feeder origin 1,4 is set at 0 (IP2).
Remedy: Enter the correct value and re-transmit the Proper data.
------------------------------
Code: 1102260D
Display:
Used by: IP2
Cause: XC 1, YC 1 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102260E
Display:
Used by: IP2
Cause: XC 2, YC 2 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102260F
Display:
Used by: IP2
Cause: XC 3, YC 3 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022610
第 154 页