FUJI错误代码查询.pdf - 第1765页
Cause: A range error occurred during vision processing and the operation was cancelled. Remedy: Check that the nozzle is clean, that no foreign matter is stuck to the part, and that the part itself is the correct one. --…
Code: 1D650012
Display: 0018
Used by:
Cause: The part was moved to where under 60% of the body width has no leads and a range error
occurred.
Remedy: None.
------------------------------
Code: 1D650016
Display: 0022
Used by:
Cause: The machine decides whether or not there are leads on the part. The machine checked half the
part and found no leads, and this error occurred. Alternately, when a bright area is searched for after a
lead, no bright area is found for more than half the part.
Remedy: Check the body size and direction in Part data (PDG).
------------------------------
Code: 1D650017
Display: 0023
Used by:
Cause: When the bumper was recognized the leads were searched for from the center and a range error
occurred.
Remedy: None.
------------------------------
Code: 1D650019
Display: 0025
Used by:
Cause: When searching for a bright area after a lead, more than half the body was searched but a bright
area was not found.
Remedy: Check the body size and direction as entered in Part data (PDG).
------------------------------
Code: 1D65001A
Display: 0026
Used by:
Cause: When the bumper was recognized the leads were searched for from the center and a range error
occurred.
Remedy: None.
------------------------------
Code: 1D65001B
Display: 0027
Used by:
Cause: The lead could not be found because the part was tilted or some related reason.
Remedy: Check that the machine is picking parts correctly.
------------------------------
Code: 1D65001C
Display: 0028
Used by:
Cause: The lead could not be found because the part was tilted or some related reason.
Remedy: Check that the machine is picking parts correctly.
------------------------------
Code: 1D65001D
Display: 0029
Used by:
第 1764 页
Cause: A range error occurred during vision processing and the operation was cancelled.
Remedy: Check that the nozzle is clean, that no foreign matter is stuck to the part, and that the part itself
is the correct one.
------------------------------
Code: 1D65001F
Display: 0031
Used by:
Cause: There are more leads on the part than the number entered in Part data (PDG).
Remedy: Check the number of leads entered in Part data (PDG), the direction, and lead information.
Check the orientation of the part as it is fed into the machine.
------------------------------
Code: 1D650020
Display: 0032
Used by:
Cause: The edge cannot be found.
Remedy: Check the number of leads entered in Part data (PDG), the direction, and lead information.
Check the orientation of the part as it is fed into the machine.
------------------------------
Code: 1D650021
Display: 0033
Used by:
Cause: A lead could not be found by searching 1/3 of the body, but when vision processing started again
a range error occurred.
Remedy: Check the number of leads entered in Part data (PDG), the direction, and lead information.
Check the orientation of the part as it is fed into the machine.
------------------------------
Code: 1D658002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D658100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D658110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D658111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
第 1765 页
------------------------------
Code: 1D658112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D658113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D658114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D658115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D658120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D658121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D658122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D658123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D6582??
Display:
第 1766 页