FUJI错误代码查询.pdf - 第858页

"No PX-Axis Servo Control Block" Used by: QP242 Cause: Internal data is corrupted. "?" indicates the module number (QP2). "****" indicates the error code. Remedy: Switch the power off and th…

100%1 / 5282
Display: "SCU?(PMC?,ICM) Error Code:********"
"PX-Axis Servo Controller Busy"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2)
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?9B
Display: "SCU?(PMC?,ICM) Error Code:********"
"PX-Axis Servo Controller Axis Stop"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
------------------------------
Code: 1207F?9C
Display: "SCU?(PMC?,ICM) Error Code:********"
"PX-Axis Servo Limit Error"
Used by: QP242
Cause: The maximum or minimum position for the axis controlled by the Robustshin servo motor has
been exceeded. Alternatively, something may be obstructing the overtravel sensor for that axis.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Return the axis in question to a position within the maximum and minimum range using the
inching keys and check those values.
------------------------------
Code: 1207F?9D
Display: "SCU?(PMC?,ICM) Error Code:********"
"PX-Axis Servo Limit Check Error"
Used by: QP242
Cause: The Robustshin servo motor attempted to move its axis to a position out side the range of its
maximum and minimum values.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: The Robustshin servo motor cannot move an axis outside the maximum or minimum range.
Check these maximum and minimum values. Alternatively, check the position to which the Robustshin
servo motor is attempting to move the axis.
------------------------------
Code: 1207F?9E
Display: "SCU?(PMC?,ICM) Error Code:********"
"No PX-Axis System Call"
Used by: QP242
Cause: System call cannot be carried out because internal data is corrupted.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?9F
Display: "SCU?(PMC?,ICM) Error Code:********"
第 857 页
"No PX-Axis Servo Control Block"
Used by: QP242
Cause: Internal data is corrupted.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1208????
Display: Same as Code.
Used by: QP132
Cause: This is the code used by production data indicating that the recovery limit was reached. The code
includes device numbers and so the number of times that recovery has been carried out can be
determined when the system creates a production data summary. The vision processing error code that
was the direct cause of the recovery processing is recorded in a different report.
The first "?" represents module number 0-F (Stage 16 is 0). The next "??" represent the slot number 0-FF,
and the last "?" represents the sub-slot number 0-F.
Remedy: This code represents the recovery code. Carry out the necessary adjustments in light of the
vision processing error which caused the recovery processing.
------------------------------
Code: 121???01
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either a result error or a time up condition occurred when the LLL board scan start command
was executed.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. If the problem continues,
turn the power off.
------------------------------
Code: 121???02
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either a result error or a time up condition occurred when the LLL board scan start command
was executed.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. If the problem continues,
turn the power off.
------------------------------
Code: 121???03
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either a result error or a time up condition occurred when the LLL board scan start command
was executed. If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) Leads
could not be measured. (Error) Check connections of encoder and sensor cables.
Remedy: Set the LLL baud rate to 9600bps or higher. Check to see if the lead length indicated in part
data is significantly different from the actual lead length. part data items: Body-Length, Body-Width
------------------------------
Code: 121???04
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either an error or a time up condition occurred when the LLL board coplanarity calculation
command was executed.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
第 858 页
------------------------------
Code: 121???05
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either an internal processing error or a time up condition occurred when the LLL board
coplanarity calculation command was executed.
Remedy: Verify that the part in question has either 2 or 4 sides with leads. The coplanarity calculation
command cannot be used for parts with leads on only 1 side. If the LLL baud rate is less than 9600bps,
set it to 9600bps or higher. (Time up) If the problem continues, turn the power off.
------------------------------
Code: 121???06
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: An error occurred when an encoder resolution setting was attempted for an LLL board.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
------------------------------
Code: 121???07
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either an error or a time up condition occurred when attempting to output engineering data to
the LLL board.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
------------------------------
Code: 121???08
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either an error or time up condition occurred when attempting to set parameter data (linearity
tolerance, coplanarity tolerance) for an LLL board.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
------------------------------
Code: 121???09
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either an error or a time up condition occurred when the LLL board scan-end command was
executed. If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) Leads could
not be measured. (Error) Check connections of encoder and sensor cables.
Remedy: Set the LLL baud rate to 9600bps or higher. Is the lead length indicated in part data
significantly different from the actual lead length? part data items: Body-Length, Body-Width
------------------------------
Code: 121???0A
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Another LLL measurement command is in progress.
Remedy: Restart the machine.
------------------------------
Code: 121???0B
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
第 859 页