FUJI错误代码查询.pdf - 第819页

Code: 1207E?19 Display: "SCU?(ICM,PMC?) Error Code:********" (QP2) "PMC Device Reqest Logic Err" (QP2) Used by: QP242,QP201,QP202,QP203 Cause: There was a logic error in a PMC device request. (value r…

100%1 / 5282
Code: 1207E?13
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Reply Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The machine was unable to respond to a request from the PMC within the specified time.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?14
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Transfer Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A board did not arrive within the specified time, resulting in a board transfer error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that board transport occurs smoothly. Make sure that the board arrival check sensor
is functioning normally.
------------------------------
Code: 1207E?15
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Transport Mode" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The command could not be executed because a board transport mode was being executed.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?16
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Feeder is Indexing" (QP2)
Feeder is Indexing.(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The machine stopped while a feeder was indexing.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)(QP2)
The machine stopped while a feeder was indexing.(NP2,QP3)
Remedy: Use I/O commands or another method to initialize the indexing feeder.
------------------------------
Code: 1207E?17
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MFU Clamp Error" (QP2)
Used by: QP242
Cause: MFU clamp timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?18
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MFU Unclamp Error" (QP2)
Used by: QP242
Cause: MFU unclamp timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
第 818 页
Code: 1207E?19
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PMC Device Reqest Logic Err" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There was a logic error in a PMC device request.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?1A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Change Sta Pos'g NG" (QP2)
Used by: QP242
Cause: There is an error in the nozzle change station upper and lower limits.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the nozzle change station. Make sure that the
upper and lower end sensors are functioning normally.
------------------------------
Code: 1207E?1B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Change Sta Pos'g NG" (QP2)
Used by: QP242
Cause: Reject conveyor operation error (positioning timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure the positioning sensor on the reject conveyor is functioning normally.
------------------------------
Code: 1207E?1C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Therml Break Trip;Rjct Conv" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Reject conveyor operation error (thermal relay tripped).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Reset the thermal relay.
------------------------------
Code: 1207E?1D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Reject Conveyor Full" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The reject conveyor is full.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the rejected parts from the reject conveyor. Make sure that the reject conveyor full
check sensor is functioning normally.
------------------------------
Code: 1207E?1E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl-Changer and Shutter Err" (QP2)
Used by: QP242
Cause: Nozzle changer/shutter operation error (timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that nothing is interfering with the nozzle change shutter. Make sure that the shutter
open and close limit sensors are functioning normally.
------------------------------
第 819 页
Code: 1207E?1F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Void Found in Flux" (QP2)
Used by: QP242
Cause: The machine stopped because a void was detected in manual void detection mode.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then execute the [AIR OUT] command.
------------------------------
Code: 1207E?20
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Flux Tank Empty" (QP2)
Used by: QP242
Cause: The flux tank has become empty. (The flux surface sensor has turned on.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then fill the flux tank.
------------------------------
Code: 1207E?21
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl Head Jointed Index Unit" (QP2)
Used by: QP242
Cause: The nozzle head cannot be lowered because it is joined to an index unit.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?22
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Automatic tape cutter error" (QP2)
Used by: QP242
Cause: The automatic tape cutter operation timed out.(QP2,QP3)
(value replacing "?" is module number; error code appears in place of asterisks)(QP2)
Remedy: Use the I/O commands to check the action of the cutter and the retract confirmation
sensor.(QP2)
Check the status (cable connections, air supply) of the PFU/MFU side displayed in the parameter. If the
problem is hardware related, restart the machine.(QP3)
------------------------------
Code: 1207E?23
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Tray;Last Tray Rejected" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There is no tray. (The last tray of a tray stacker has been ejected.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then supply tray components.
------------------------------
Code: 1207E?24
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Rejection Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Tray ejection timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the STU and the tray ejection unit for problems.
------------------------------
第 820 页