Display: A feeder included in fixed feeder processing cannot be loaded on the stage because it is too close to the feeder to the left. Used by: Cause: In the program's feeder setup, a feeder wide enough to interfere…
Cause: The Part data, referred to by a sequence slot that contains no skipped board/feeder/sequence
setting, does not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23040008
Display: No feeder exists in the slot referenced by this skipped sequence (for skipped sequences included
in optimization).
Used by:
Cause: A feeder does not exist in a sequence slot that contains board/feeder/sequence skip settings.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2304000A
Display: Part data referred to by the skip sequence does not exist. This error can be avoided by selecting
[Lines to Skip are Removed] when you optimize.
Used by:
Cause: The part data referred to by a sequence slot containing board/feeder/sequence skip settings does
not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2304000D
Display: The Alt. Feeder does not exist. Do you want to set 0 for alternate feeder?
Used by:
Cause: A feeder is not set in the alternate feeder specified for the displayed stage-slot.
Remedy: The Feeder Setup information in the program file is incorrect. Check the settings.
------------------------------
Code: 2304000E
Display: There are too many feeders allocated to one stage.
Used by:
Cause: When automatic feeder arrangement was selected at the Optimize Condition settings screen, the
number of feeders allocated to the stage exceeded the maximum feeder slots.
Remedy: Firstly, try changing the [Use feeder type] settings. If unsuccessful, perform optimization using
the [Alt. Feeders are Removed] setting. If still unsuccessful, reduce the part varieties used in the program.
------------------------------
Code: 23040010
Display: Part data referred to by the unused feeders in the [Fix Feeder Slots] does not exist. (Even for
unused feeder(s) without part data, it can't be determined whether the feeder is set at the machine.) This
error can be avoided by selecting [Automatic Most Suitable Feeder Arrangement] when you optimize.
Used by:
Cause: There is no part data displayed in the Feeder Setup.
Remedy: The program file data is incorrect. Check the contents.
------------------------------
Code: 23040012
Display: The slot number does not exist at the machine. This error can be avoided by selecting [Automatic
Most Suitable Feeder Arrangement] when you optimize.
Used by:
Cause: The specified stage - slot number does not exist.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23040015
第 2141 页
Display: A feeder included in fixed feeder processing cannot be loaded on the stage because it is too close
to the feeder to the left.
Used by:
Cause: In the program's feeder setup, a feeder wide enough to interfere with the adjacent feeder on the
left side.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 2304001A
Display: Are you finished?
Used by:
Cause: The confirmation dialog displays at each time of completion.
Remedy: Select [Yes] to finish. Select [No] to continue.
------------------------------
Code: 2304001B
Display: The optimized program has not been saved yet. Will you save it?
Used by:
Cause: Attempting to open the program file, or optimization process has completed, but the optimized
program has not been saved to the file.
Remedy: Select [Yes] to display the dialog for saving the file with a new name.
When attempting to open the program file, select [No] to abandon the optimized program, and display the
dialog for selecting a new program file to be optimized.
When optimization process has completed, select [No] to exit without saving the optimized program.
------------------------------
Code: 2304001C
Display: No nozzle is registered.
Used by:
Cause: No valid nozzle match could be made between the Nozzle Config. file's NCFTYPE and the Nozzle
Spec. file's NSPNAME.
Remedy: There is a problem with either or both files. Normally, the Nozzle Config. and Nozzle Spec. files
in the MCS-X default directory are read automatically. Check that both files contain correct data. When
starting up the optimizer, in cases where prompted to specify a file because the default file cannot be
found, check the file contents and correct if necessary.
------------------------------
Code: 2304001D
Display: Nozzle Configuration File "Fujinzl.cfg" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 2304001E
Display: The contents of Nozzle Configuration File are empty.
Used by:
Cause: The Nozzle Config. file is empty.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
第 2142 页
Code: 2304001F
Display: Contents are not Nozzle Configuration File.
Used by:
Cause: The field "UNIT", "NZLCONF" does not exist.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040020
Display: Cannot read the file.
Used by:
Cause: An error occurred while reading the Nozzle Config. file.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040021
Display: There are no data for "XP-141" in the file.
Used by:
Cause: XP-141 Nozzle Config. information (XP141 specified in NZLCONF/HEADER/TYPE) does not exist.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040024
Display: The nozzle items "NCFNAME" or "NCFTYPE" do not exist in the file.
Used by:
Cause: The Nozzle Name and Nozzle Type cannot be obtained because either or both of the fields,
"NCFNAME" and "NCFTYPE" are missing from underneath the ["BLOCK","CONFIG+"] field in the XP-141
Nozzle Config. information file (XP141 specified in NZLCONF/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040025
Display: A syntax error occurred because the data field count does not agree with the number of nozzle
configuration items.
Used by:
Cause: The item count in the field immediately following the ["BLOCK","CONFIG+"] field in the XP-141
Nozzle Config. information file (XP141 specified in NZLCONF/HEADER/TYPE) does not match the actual
number of items in the fields below that field.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040026