Code: 1D0B0014 Display: Used by: Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wr…

100%1 / 5282
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B000E
Display:
Used by:
Cause: The lead is too long.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B000F
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0010
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0011
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0012
Display:
Used by:
Cause: The part is tilted too much.
Remedy: Check that the CCD level and vision processing is operating normally.
------------------------------
Code: 1D0B0013
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
第 1340 页
Code: 1D0B0014
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0015
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0016
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B0017
Display:
Used by:
Cause: A correct image could not be taken. The lead or a related item is defective. Alternately, one or
more of the values entered in Part data (PDG) (such as Lead length or Pitch) are wrong and therefore vision
processing cannot be carried out.
Remedy: Check that the nozzle is not dirty, that foreign matter is not stuck to the part and that the
correct part was picked.
------------------------------
Code: 1D0B4001
Display:
Used by:
Cause: A Part data entry is missing.
Remedy: Check Part data.
------------------------------
Code: 1D0B4002
Display:
Used by:
Cause: The left or right area cannot be found.
Remedy: Check the direction in which the part is oriented when it is fed into the machine. Check that
vision processing is operating normally.
------------------------------
Code: 1D0B4003
Display:
第 1341 页
Used by:
Cause: A Part data entry is missing.
Remedy: Check Part data.
------------------------------
Code: 1D0B4004
Display:
Used by:
Cause: A Part data entry is missing.
Remedy: Check Part data.
------------------------------
Code: 1D0B4005
Display:
Used by:
Cause: The Y direction is too long.
Remedy: Check the part, and check that the vision processing system is working correctly (check the
image).
------------------------------
Code: 1D0B4006
Display:
Used by:
Cause: The upper and lower area could not be found.
Remedy: Check the lead width, the lead length and check that the vision processing system is working
correctly (check the image).
------------------------------
Code: 1D0B4007
Display:
Used by:
Cause: The upper and lower area could not be found.
Remedy: Check the lead width, the lead length and check that the vision processing system is working
correctly (check the image).
------------------------------
Code: 1D0B4008
Display:
Used by:
Cause: The lead is too long.
Remedy: Check the part size, and check that the vision processing system is working correctly (check the
image).
------------------------------
Code: 1D0B4009
Display:
Used by:
Cause: The lead is too long.
Remedy: Check the part size, and check that the vision processing system is working correctly (check the
image).
------------------------------
Code: 1D0B400A
Display:
Used by:
Cause: The Y direction is too long.
Remedy: Check the part size, and check that the vision processing system is working correctly (check the
image).