FUJI错误代码查询.pdf - 第846页
"TY-Axis Encorder Counter Overflow" Used by: QP242 Cause: During axis movemen,the maximum counter value was exceeded. "?" indicates the module number (QP2). "****" indicates the error code. …
"****" indicates the error code.
Remedy: Check that the servo unit is properly connected.
------------------------------
Code: 1207F?51
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?52
Display: "SCU?(PMC?,ICM) Error Code:********"
"The TY-Axis Servo is OFF or an alarm is active."
Used by: QP242
Cause: The TY-axis servo is off or an alarm is active.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: If the TY-axis servo is off, check that the servo controller is being supplied with power. If an
alarm is active, clear the alarm and restart operation.
------------------------------
Code: 1207F?53
Display: "SCU?(PMC?,ICM) Error Code:********"
"A TY-axis servo parameter have not been set."
Used by: QP242
Cause: Check the parameters for the TY-axis.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Set the TY-axis servo parameters, supply power and restart operation.
------------------------------
Code: 1207F?54
Display: "SCU?(PMC?,ICM) Error Code:********"
"Cancellation by TY-Axis stop command."
Used by: QP242
Cause: Axis operation terminated because a separate error occurred during communication.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?55
Display: "SCU?(PMC?,ICM) Error Code:********"
"Error prior to TY-Axis Encorder Counter Operation"
Used by: QP242
Cause: The machine attempted to take an encoder count before the current count had been confirmed.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?56
Display: "SCU?(PMC?,ICM) Error Code:********"
第 845 页
"TY-Axis Encorder Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?57
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Encorder Counter Recieving Error"
Used by: QP242
Cause: An error occurred at the TY-axis servo controller when receiving data.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?58
Display: "SCU?(PMC?,ICM) Error Code:********"
"Disconnected TY-Axis"
Used by: QP242
Cause: TY-axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?59
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Servo Controller Timeout"
Used by: QP242
Cause: The TY-axis timed out.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?5A
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Servo Controller Busy"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2)
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?5B
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Servo Controller Axis Stop"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
第 846 页
------------------------------
Code: 1207F?5C
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Servo Limit Error"
Used by: QP242
Cause: The maximum or minimum position for the axis controlled by the Robustshin servo motor has
been exceeded. Alternatively, something may be obstructing the overtravel sensor for that axis.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Return the axis in question to a position within the maximum and minimum range using the
inching keys and check those values.
------------------------------
Code: 1207F?5D
Display: "SCU?(PMC?,ICM) Error Code:********"
"TY-Axis Servo Limit Check Error"
Used by: QP242
Cause: The Robustshin servo motor attempted to move its axis to a position out side the range of its
maximum and minimum values.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: The Robustshin servo motor cannot move an axis outside the maximum or minimum range.
Check these maximum and minimum values. Alternatively, check the position to which the Robustshin
servo motor is attempting to move the axis.
------------------------------
Code: 1207F?5E
Display: "SCU?(PMC?,ICM) Error Code:********"
"No TY-Axis System Call"
Used by: QP242
Cause: System call cannot be carried out because internal data is corrupted.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?5F
Display: "SCU?(PMC?,ICM) Error Code:********"
"No TY-Axis Servo Control Block"
Used by: QP242
Cause: Internal data is corrupted.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?60
Display: "SCU?(ICM,PMC?) Error Code:********"
"FX-Axis Servo Alarm Controller Error"
Used by: QP242
Cause: Processing cannot be performed during an emergency stop.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: After releasing the emergency stop button, restart operation.
------------------------------
第 847 页