For nozzle numbers above 256, 256 is displayed. Used by: QP242,QP201,QP202,QP203 Cause: Cannot change to the specified nozzle. Remedy: Do not set nozzle positions in NAT which have not been measured or do not exist. ----…
Used by: QP242,QP201,QP202,QP203
Cause: The part body sizes X and Y in part data are larger than the reject parts conveyor sizes.
The first "?" represents the station number and the following "??" represent the device slot within the
station. Since the device slot number is represented in hexadecimal form, subtract 256 from any number
greater than 256.
Remedy: Change body size X, or Y, to a size smaller than the reject parts conveyor size. Alternatively, set
a size for the reject parts conveyor in Proper data large enough to accommodate the size of the part.
------------------------------
Code: 11D68???
Display: Same as Code.
Used by: QP242,QP201,QP202,QP203
Cause: The size of the scan area for the line scan camera is too large.
The first "?" represents the station number and the following "??" represent the device slot within the
station. Since the device slot number is represented in hexadecimal form, subtract 256 from any number
greater than 256.
Remedy: Reduce the values specified at part data items, "scan_area_x" and "scan_area_y" as they
currently exceed the possible maximum scan area of the line scan camera. If "0" has been specified at
these items, vision processing according to the part's sizes cannot be performed.
------------------------------
Code: 11D69???
Display: Same as code.
Used by: QP242,QP201,QP202,QP203
Cause: Placing pressure control is being used during part pick-up at a module which is not equipped
with a placing pressure control sensor.
The first "?" represents the station number and the following "??" represent the device number within the
station. The numbering is hexadecimal. For device numbers higher than 256, subtract 256.
Remedy: Pressure control is used for the part assigned to this device when it is picked up. Change the
program so that the part is picked up at a module which is equipped with a placing pressure control
sensor.
------------------------------
Code: 11D6A???
Display: Same as code.
Used by: IP-3
Cause: The camera type specified in Proper data does not match the "Lighting" and "Fst_pin_chk"
settings in part data.
The first "?" indicates the stage number, the second two "??" indicate the slot number within the stage.
This is in hexadecimal notation. Subtract 256 for values larger than 256.
Remedy: Ensure the "Lighting" and "Fst_pin_chk" settings match those shown below:
Cameras other than type 12,13 Camera type 12,13
Back_light NON, IC, IC_FIRST, IC_180, NON, IC, IC_FIRST, IC_180,
CUT CUT
Front_light_A NON, IC, IC_FIRST, IC_180, NON, IC, IC_FIRST, IC_180,
CUT, BUMP CUT
Front_light_B *** NON, IC, IC_FIRST, IC_180,
CUT, MARK, BUMP
Front_light_AB *** NON, IC, IC_FIRST, IC_180
------------------------------
Code: 11D70???
Display: 11D70???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the nozzle number in that station.
第 285 页
For nozzle numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: Cannot change to the specified nozzle.
Remedy: Do not set nozzle positions in NAT which have not been measured or do not exist.
------------------------------
Code: 11D82301
Display: Nozzle data error
Used by: CP732
Cause: Unable to distinguish the nozzles used for the parts placement.
Remedy: Verify that the nozzle name has been specified in Part Data.
------------------------------
Code: 11E000??
Display: Non
Used by: CP642,CP642M
Cause: The associated master device of the reported pair device has not been specified in device data.
The pair device number is represented by the question marks.
Remedy: Specify the master device number in sequence data.
------------------------------
Code: 11E001??
Display: Non
Used by: CP642,CP642M
Cause: The associated master device of the reported pair device has been specified more than once in
device data. The pair device number is represented by the question marks.
Remedy: Specify the master device number only once in sequence data.
------------------------------
Code: 11E002??
Display: Non
Used by: CP642,CP642M
Cause: The associated slave device of the reported pair device has not been specified in device data. The
pair device number is represented by the question marks.
Remedy: Specify the slave device number in sequence data.
------------------------------
Code: 11E003??
Display: Non
Used by: CP642,CP642M
Cause: A slave device associated with a different paired device is present in the slave device loop of the
reported pair device. The pair device number is represented by the question marks.
Remedy: Ensure that the slave device loop contains only slave devices for the associated paired device.
------------------------------
Code: 11E004??
Display: Non
Used by: CP642,CP642M
Cause: The slave device loop for the reported device has been specified more than once. The device
number is represented by the question marks.
Remedy: Ensure that there is only one slave device loop per paired device.
------------------------------
Code: 11E005??
Display: Non
Used by: CP642,CP642M
Cause: The specified paired device number of the reported device is outside the permissible range. The
device number is represented by the question marks.
第 286 页
Remedy: Ensure that the paired device number is within the range of 000 - 255.
------------------------------
Code: 11E006??
Display: None
Used by: CP43,FCP6,CP6M,CP642,CP642M
Cause: During use of the pair parts function, the value specified at the part data item "Empty_cavities" is
outside the acceptable range (CP-6-series), or the specified recovery setting is outside the acceptable range
(CP-43). The question marks (??) represent the device number in hexadecimal format.
Remedy: Set the number of empty cavities within the range of 2 to 10, and set the number of recovery
attempts within the range of 0 to 4.
------------------------------
Code: 12010101
Display: 紧急停止开关 NG EMERGENCY(CP3)
Used by: CP3,CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP
1,IP3,QP242,QP201,QP202,QP203,QP132,NP132,NP133,CP-732E,CP-742ME,CP-742E,CP-
752E,GPX,NXTP
Cause: 紧急停止开关被按下了。
Remedy: 请复位紧急停止开关。紧急停止开关带有锁定功能。朝箭头方向(顺时针方向)转动后,锁定就会被解除。
·请按下电源关闭按钮,关闭电源。(CP3)
·请按下电源关闭按钮关闭电源(结束生产时)或者按下复位按钮。(GL)
<img src="$LKEY_ERRIMG_MC$/12010101.PNG">
------------------------------
Code: 12010201
Display: “ 周期停止 ”
Used by: GSP2,GSP3,GSP5,GP2,GP3,IP1,GPX
Cause: 周期停止开关被按下了。
Remedy: 请按下复位按钮。
------------------------------
Code: 12010202
Display: 来自外部输入的停止信号ON
Used by: GPX,NXTP
Cause: 由于来自外部输入的停止信号ON着,因此停止了机器
Remedy: 请确认外部工程是否因错误而停止了。
<img src="$LKEY_ERRIMG_MC$/12010202.PNG">
------------------------------
Code: 12010301
Display:
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,IP1
Cause: The matching production program is finished.
Remedy: None.
------------------------------
Code: 12010401
Display: 完成了生产预定块数(CP5) PRODUCTION COMPLETE(CP3)
完成生产预定块数(GL,GSP2,IP2)
完成生产预定块数。(NP2,QP3)
Used by: CP3,CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,GP551,GP6,IP1,NP2,QP3,
GPX
Cause: 完成了生产预定块数。
Remedy: 请在PROGRAM - QTYCLR 中清除生产块数。(CP3,GL)