Display: 1102233F Used by: CP6,CP6M,CP65,CP642,CP643 Cause: The Handy Terminal type setting in Proper Data is inappropriate. Remedy: if the handy terminal software version is H2.10,set "Barcode Reader Type" in …

100%1 / 5282
Used by: CP4-1,CP4-2,CP4-3
Cause: The fine theta axis angle of rotation is greater than the limit set in Proper data.(CP4-1,CP4-2) The
results of component vision processing indicate a compensation amount exceeding 30 mm in the Q
direction.(CP4-3)
Remedy: Check the manner in which the component is picked up, and make sure that the device offset
value is appropriate.(CP4-1,CP4-2,CP4-3) Alternately, set the Proper data item q_correct_limit to a larger
value. Default is 30000 (set in increments of 1/1000 degree).(CP4-1,CP4-2)
------------------------------
Code: 11022339
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Max Limit Position T1 and Min Limit Position T1 have no values entered.
Remedy: Measure these values (refer to the Proper data measurement manual) and input appropriate
values in Proper data.
------------------------------
Code: 1102233A
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Max Limit Position T2 and Min Limit Position T2 have no values entered.
Remedy: Measure these values (refer to the Proper data measurement manual) and input appropriate
values in Proper data.
------------------------------
Code: 1102233B
Display:
Used by: CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: An appropriate value for Proper data's Pickup Position for device table 2 has not been entered.
Remedy: Measure this value (refer to the Proper data measurement manual) and input appropriate values
in Proper data.
------------------------------
Code: 1102233C
Display: 1102233C
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The nozzle place offset X is unsuitable (CP6).
Remedy: The nozzle place offset X is set to less than -2000 or more than 2000. Enter an appropriate
value.
------------------------------
Code: 1102233D
Display: 1102233D
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The nozzle place offset Y is unsuitable (CP6).
Remedy: The nozzle place offset Y is set to less than -2000 or more than 2000. Enter an appropriate
value.
------------------------------
Code: 1102233E
Display: 1102233E
Used by: CP6,CP6M,CP65,CP652C,CP642
Cause: The machine size setting in Proper data is incorrect (FCP6).
Remedy: Set the Proper data item 141.M/C Size 4000 5000 to 4000 for a type 4000 machine and 5000 for
a type 5000 machine.
------------------------------
Code: 1102233F
第 144 页
Display: 1102233F
Used by: CP6,CP6M,CP65,CP642,CP643
Cause: The Handy Terminal type setting in Proper Data is inappropriate.
Remedy: if the handy terminal software version is H2.10,set "Barcode Reader Type" in Proper data to "4".
if the handy terminal software version is H3.00,set "Barcode Reader Type" in Proper data to "5".
------------------------------
Code: 11022340
Display: 11022340
Used by: CP643,CP643M
Cause: The setting for the resupply position (Parts replace Pos T1) for device table 1 is not between the
retract position (D1 Origin Position) and the pick-up position (Pickup Position T1).
Remedy: Correct the Proper data settings for the resupply position for device table 1, and retransmit
Proper data to the machine.
------------------------------
Code: 11022341
Display: 11022341
Used by: CP643,CP643M
Cause: The setting for the resupply position (Parts replace Pos T2) for device table 2 is not between the
retract position (D2 Origin Position) and the pick-up position (Pickup Position T2).
Remedy: Correct the Proper data settings for the resupply position for device table 2, and retransmit
Proper data to the machine.
------------------------------
Code: 11022342
Display: 11022342
Used by: CP643,CP643M
Cause: The middle loading position item in Proper data is set to a value that may result in collision with
the carrier.
Remedy: Set the middle loading position item in Proper data to a position 20mm or more above Loading
Position Z.
------------------------------
Code: 11022343
Display: 11022343
Used by: CP643,CP643M
Cause: The values for Loading position Y_IN and Y_OUT in Proper data are invalid.
Remedy: The values for Loading position Y_IN and Y_OUT in Proper data are different, preventing smooth
loading and unloading of panels. Perform loading position measurements once again, set identical values
in Proper data, and transmit to the machine.
------------------------------
Code: 11022344
Display: 11022344
Used by: CP43,CP6,CP6M,CP65,CP642,CP&42M,CP643,CP643M
Cause: Neither the Handy Terminal nor a forced device check can be specified in the case where feeder
verification settings have been made in Proper data.
Remedy: Retransmit Proper data after canceling the feeder verification settings (do not set ∪4∩ in
Machine ID), or after canceling the Handy Terminal and forced device check settings (Verifier
Tool:Non/Device Check SW:NO).
------------------------------
Code: 11022400
Display:
Used by: GL2,GL5,GL541
Cause: The data does not match machine specifications (Ep, GL1, GL2, IP1).
第 145 页
Remedy: Check the Proper data to ensure that the Proper data in the file is the Proper data for the
machine.
1. Print out the Proper, and after inputting new Proper, transmit this to the machine.
2. Check that the machines registered in the MCS line descriptor are correct.
3. Check that the channel to which the data line cable is connected is correct.
------------------------------
Code: 11022401
Display:
Used by:
Cause: The Proper data item Device_No_xx is out of range (EP, GL1).
Remedy: Check the Proper data item Device_No_xx.
------------------------------
Code: 11022402
Display:
Used by:
Cause: The Proper data items Pathlight_flag, PCB_flow_direction are out of range (EP, GL1).
Remedy: Check the Proper data items Pathlight_flag, PCB_flow_direction.
------------------------------
Code: 11022403
Display:
Used by:
Cause: The Proper data items inching_speed, V_max, zero_speed are out of range (EP, GL1).
Remedy: Check the Proper data items inching_speed, V_max, zero_speed.
------------------------------
Code: 11022404
Display:
Used by:
Cause: The Proper data items Inbuffer_flg, check_glue, Q_axis_type are out of range (EP, GL1).
Remedy: Check the Proper data items Inbuffer_flg, check_glue, Q_axis_type.
------------------------------
Code: 11022405
Display:
Used by:
Cause: The Proper data items X0, Y0, Q0, DX0, DY0 are out of range (EP, GL1).
Remedy: Check the Proper data items X0, Y0, Q0, DX0, DY0.
------------------------------
Code: 11022406
Display:
Used by:
Cause: The Proper data item timerA~timerJ is out of range (EP, GL1).
Remedy: Check the Proper data item timerA~timerJ.
------------------------------
Code: 11022407
Display:
Used by:
Cause: The Proper data item syringe_offset is out of range (EP, GL1).
Remedy: Check the Proper data item syringe_offset.
------------------------------
Code: 11022408
Display:
Used by: