Used by: QP242,QP201,QP202,QP203,QP132 Cause: Y-axis command pulse error (outside software limit range). (value replacing "?" is module number; error code appears in place of asterisks) (value replacing "?…

100%1 / 5282
Remedy: Check that the Z-axis operates normally. Check that the Z-axis speed reduction point sensor is
operating normally.
------------------------------
Code: 12074?1B
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Failed to reset servo amp." (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Failed to clear servo amp error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET button again.
------------------------------
Code: 12074?1C
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Feeder set error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A tape leaf error has been detected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Make sure the feeder is properly set. Make sure the tape leaf detection sensor is functioning
normally.
------------------------------
Code: 12074?1D
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Plcg. pressure sensor error" (QP2)
Regular placing pressure control alarm (QP3)
Used by: QP242,QP341,QP351
Cause: The placing pressure confirmation sensor did not turn on when the nozzle descended to the
provisional position for pressure control.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)
Placing pressure check sensor did not come ON. Sensor is damaged or position of sensor is
incorrect.(QP3)
Remedy: Check whether the placing pressure confirmation sensor is functioning normally and whether it
is attached at the correct position.(QP2)
Check sensor position.(QP3)
------------------------------
Code: 12074?20
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Command Out of Soft Lim (X)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis command pulse error (outside software limit range).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The X-axis movement target position exceeds the limit values specified in the Proper data.
Check the movement target value and the Proper data values.
------------------------------
Code: 12074?21
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Command Out of Soft Lim (Y)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
第 773 页
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis command pulse error (outside software limit range).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The Y-axis movement target position exceeds the limit values specified in the Proper data.
Check the movement target value and the Proper data values.
------------------------------
Code: 12074?22
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Command Out of Soft Lim (Z)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Z-axis command pulse error (outside software limit range).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The Z-axis movement target position exceeds the limit values specified in the Proper data.
Check the movement target value and the Proper data values.
------------------------------
Code: 12074?23
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Command Out of Soft Lim (Q)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Q-axis command pulse error (outside software limit range).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The Q-axis movement target position exceeds the limit values specified in the Proper data.
Check the movement target value and the Proper data values.
------------------------------
Code: 12074?31
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake error).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?32
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake timeout1).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?33
Display: PM?? ERROR Code:********
第 774 页
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake timeout2).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?40
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(No data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?41
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake timeout1).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?42
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Handshake timeout2).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12074?43
Display: PM?? ERROR Code:********
Used by: QP132
Cause: PMC board communication error. SVdata transmission error(Block count error).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12076?02
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"X-axis(-) Overtravel" (QP2)
第 775 页