FUJI错误代码查询.pdf - 第901页
Display: Event error Used by: Cause: The event object became invalid. Remedy: Reinstall software,if this error cannot be corrected after reboot, because the conveyor control function could be damaged. -------------------…
Code: 12201003
Display: CRC error.
Used by:
Cause: An error has occurred during communication.
Remedy: Replace conveyor control board with a new one if no abnormalities are found, because the
conveyor control board could be damaged.
------------------------------
Code: 12201004
Display: Cover opening.
Used by:
Cause: Conveyor's cover is open.
Remedy: Close a conveyor's cover.
------------------------------
Code: 12201005
Display: Emergency Stop.
Used by:
Cause: The emergency stop button was pressed.
Remedy: Reset the emergency stop button.
------------------------------
Code: 12201006
Display: Encoder error.
Used by:
Cause: The battery of the encoder for the backup fell to equal to or less than 2.8 V.
Remedy: There is possibility that the position data of the encoder disappeared.
------------------------------
Code: 12201007
Display: Battery error.
Used by:
Cause: The battery of the encoder for the backup fell to equal to or less than 3.0 V.
Remedy: Exchange a battery of the encoder for the backup.
------------------------------
Code: 12201009
Display: Conveyor's width error.
Used by:
Cause: The software limit of Conveyor's width is over.
Remedy: After confirming a maximum and a minimum value, input once more.
------------------------------
Code: 1220100A
Display: Movement error.
Used by:
Cause: The operation didn't end normally by some factor.
Remedy: After removing an extraordinary factor, operation be resumed.
------------------------------
Code: 1220100B
Display: Communication error.
Used by:
Cause: Communication between the host and the conveyor control board wasn't established in the time.
Remedy: Replace conveyor control board with a new one if no abnormalities are found, because the
conveyor control board could be damaged.
------------------------------
Code: 12201014
第 900 页
Display: Event error
Used by:
Cause: The event object became invalid.
Remedy: Reinstall software,if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201015
Display: Timeout
Used by:
Cause: The communication didn't complete to the conveyor control board with the host in the time.
Remedy: Resume operation after checking that the connection cable of a communication port has not
separated.
------------------------------
Code: 12201016
Display: CRC error
Used by:
Cause: An error has occurred during communication.
Remedy: Please reboot ,after checking connection of cable.
If this error cannot be corrected, the conveyor control board could be damaged.
------------------------------
Code: 12201017
Display: Retry over
Used by:
Cause: Communication wasn't established to the conveyor control board after retry.
Remedy: Please reboot ,after checking connection of cable.
If this error cannot be corrected, the conveyor control board could be damaged.
------------------------------
Code: 12201018
Display: Shared memory error
Used by:
Cause: The version of the modules may not be adjusted.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201019
Display: Command error
Used by:
Cause: After executing a command, it becomes extraordinary ending.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 1220101A
Display: Failed to send command.
Used by:
Cause: A command could not be send to the conveyor control board.
Remedy: After confirming whether or not the connection cable at the communication port doesn't come,
operation be resumed.
------------------------------
Code: 1220101F
Display: Failed to start shell.
Used by:
第 901 页
Cause: The conveyor shell could not start normally .
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201020
Display: Failed to terminate dll.
Used by:
Cause: The conveyor shell could not terminate normally.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201028
Display: Abnormal parameter.
Used by:
Cause: Because the parameter when using an API was an incorrect, the function could not be executed.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201032
Display: Communication port error.
Used by:
Cause: Conveyor control function wasn't possible to do the opening or the closing of the communication
port.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201033
Display: Que error.
Used by:
Cause: The Que in conveyor control function was full.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12202001
Display: Device communication error.
Used by:
Cause: The received data is incorrect data.
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12202002
Display: Queue buffer full.
Used by:
Cause: DxShell API function is called by mistake.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202003
Display: Association Suspended.
Used by:
第 902 页