FUJI错误代码查询.pdf - 第25页

Display: Used by: Cause: The device description ID number has not been recorded in Part data (device numbers 26~39 on the CP4 and 28~41 on the CP5). Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at…

100%1 / 5282
Used by:
Cause: There is non-numerical data in the header data.
Remedy: Check the header data.
------------------------------
Code: 11011063
Display:
Used by:
Cause: The header data is incorrect.
Remedy: Check the header data.
------------------------------
Code: 11011064
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541
Cause: The end does not match n_max.
Remedy: Re-transmit the program.
------------------------------
Code: 11011065
Display:
Used by:
Cause: There is no end.
Remedy: Re-transmit the program.
------------------------------
Code: 11011066
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There is no sequence end bit (CP4).
Remedy: Re-transmit the program.
------------------------------
Code: 11011067
Display: LIMIT ERROR
Used by: CP3
Cause: The servo axis target is out of range (CP).
Remedy: Check and fix the program. Re-transmit the program.
------------------------------
Code: 11011070
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 1~13 on the CP4 and CP5).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011071
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 14~26 on the CP4, and 14~27 on the CP5).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011072
第 24 页
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 26~39 on the CP4 and 28~41 on the CP5).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011073
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 40~52 on the CP4 and 42~55 on the CP5).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011074
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 53~65 on the CP4 and 56~69 on the CP5).
Remedy: On versions MCS/2 t2.30 and later, enter ":idg -a" at the UCI menu.
------------------------------
Code: 11011075
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 66~78 on the CP4 and 70~83 on the CP5).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011076
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 79~91 on the CP4 and 84~97 ).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011077
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 92~104 on the CP4 and 98~111 on the CP5).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011078
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 105~117 on the CP4 and 112~1225 on the CP5).
第 25 页
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011079
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 118~130 on the CP4 and 126~139 on the CP5).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 1101107A
Display:
Used by:
Cause: The device description ID number has not been recorded in Part data
(device numbers 131~140 on the CP4 and 140~153 on the CP5).
Remedy: On MCS/2 versions t2.30 and later, enter ":idg -a" at the UCI menu. On MCS/2 versions t2.2a
and earlier, input a unique device description ID number in Part data.
------------------------------
Code: 11011080
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: The nozzle size specified in the part data item,"Nozzle_size_CP4" cannot be found in the program
items "S_nozzle_size","M_nozzle_size",or "L_nozzle_size"(CP4, CP43). The nozzle size specified in the part
data item, "Nozzle_size_CP6" cannot be found in the nozzle assignment table(CP-6/6M/65/642). The
applicable part data is that listed in lines 1-13 in "D_data".
Remedy: For the CP4 or CP43, change the value for one of the program
items,"S_nozzle_size","M_nozzle_size",or "L_nozzle_size",so that it is the same as the value specified for the
part data item,"Nozzle_size_CP4". For the CP-6/6M/65/642, change the nozzle assignment table to
include the nozzle specified in the part data item,"Nozzle_size_CP6". Alternatively, in either case, change
the part data. if it is okay for the nozzle to be selected automatically, set the part data
item,"Nozzle_size_CP4" or "Nozzle_size_CP6" to "0".
------------------------------
Code: 11011081
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: The nozzle size specified in the part data item,"Nozzle_size_CP4" cannot be found in the program
items "S_nozzle_size","M_nozzle_size",or "L_nozzle_size"(CP4, CP43). The nozzle size specified in the part
data item, "Nozzle_size_CP6" cannot be found in the nozzle assignment table(CP-6/6M/65/642). The
applicable part data is that listed in lines 14-26 in "D_data".
Remedy: For the CP4 or CP43, change the value for one of the program
items,"S_nozzle_size","M_nozzle_size",or "L_nozzle_size",so that it is the same as the value specified for the
part data item,"Nozzle_size_CP4". For the CP-6/6M/65/642, change the nozzle assignment table to
include the nozzle specified in the part data item,"Nozzle_size_CP6". Alternatively, in either case, change
the part data. if it is okay for the nozzle to be selected automatically, set the part data
item,"Nozzle_size_CP4" or "Nozzle_size_CP6" to "0".
------------------------------
Code: 11011082
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: The nozzle size specified in the part data item,"Nozzle_size_CP4" cannot be found in the program