FUJI错误代码查询.pdf - 第464页
occurred. Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected, notify Fuji. ------------------------------ Code: 12037A8? Display: Reduce data creation error Used by: CP3…
Code: 12037A2?
Display: INTL SRV initialize error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GP551,GP6
Cause: Initialization of the intelligent servo board is not complete. This error occurred when Fuji OS
system call_intl_init_chk() was used. The last number in the error code indicates the board number in
which the error occurred. 0 indicates the first board.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A3?
Display: PI SRV creation error
Used by:
Cause: An error occurred when an attempt was made to generate the driver which performs servo driver
PI control. This error occurred when Fuji OS system call_create_pi_srv() was used. The last number in
the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A4?
Display: TBA SRV creation error
Used by: CP3
Cause: An error occurred when an attempt was made to generate the driver which controls the
acceleration speed of the servo driver. This error occurred when Fuji OS system call_create_tba_srv() was
used. The last number in the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A5?
Display: OLD SRV creation error
Used by: CP4-1,CP4-2,CP4-3,GL541,GP551,GP6
Cause: An error occurred during an attempt to generate the driver which controls the target value. This
error occurred when Fuji OS system call_create_old_srv() was used. The last number in the error code
indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A6?
Display: CNT SRV creation error
Used by:
Cause: An error occurred when an attempt was made to generate the counter driver for the system which
uses 8253 (PIT). This error occurred when Fuji OS system call_create_cnt_srv() was used. The last
number in the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A7?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GL541,GP551,GP6
Cause: An error occurred due to a lack of memory when an attempt was made to generate the
deceleration function data used by the servo. This error occurred when Fuji OS system
call_create_reduce() was used. The last number in the error code indicates the axis in which the error
第 463 页
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A8?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo because the parameter-specified deceleration time was too long. This error occurred when Fuji
OS system call_create_reduce() was used. The last number in the error code indicates the axis in which
the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A9?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo because the parameter-specified generate size was out of range. This error occurred when Fuji
OS system call_create_reduce() was used. The last number in the error code indicates the axis in which
the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AA?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo. This error occurred when Fuji OS system call_create_reduce() was used. The last number in
the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AB?
Display: Accel data creation error
Used by: CP3
Cause: An error occurred due to a lack of memory when an attempt was made to generate the
acceleration function data used by the servo. This error occurred when Fuji OS system
call_create_reduce() was used. The last number in the error code indicates the axis in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AC?
Display: Accel data creation error
Used by: CP3
Cause: An error occurred when an attempt was made to generate the acceleration function data used by
the servo because the specified parameter was unsuitable. This error occurred when Fuji OS system
call_create_accel() was used. The last number in the error code indicates the axis in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
第 464 页
notify Fuji.
------------------------------
Code: 12037AD?
Display: INTL SRV version error
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541
Cause: This error involves the internal processing of the machine software. The "intelligent Servo Power
Version Check" with " system call_intl_ver_chk()" discovered the FUJI OS to be v2.17 or earlier.The last
digit of the error code indicates the number of the board in which the error occurred. "0" indicates board
one. (? represents the board in which the error occurred.)
Remedy: Boot up the machine using the reset-start procedure. If the machine still does not work properly
or if this problem occurs often, contact Fuji.
------------------------------
Code: 12038000
Display:
Used by: CP732E,CP742ME,CP742E,CP752E,NP133E,NP134E,NP153E
Cause: Control power for the servo amplifier was cut due to an outage of 100msec,resulting in an
encoder communication error. This error is caused when the servo amplifier's control power is cut, not
due to an error in the encoder itself.
Remedy: Be sure to shutdown the machine according to the instructions on the monitor and restart the
machine.
------------------------------
Code: 12040101
Display: TAPE END
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: Even though there are still parts in the tape,the machine(CP3) has detected the end of the tape
end and has stopped operation. The machine stops underthese conditions only if the third bit in
"Machine_status" is set to "1"(4H).
Alternatively, when the large part check is performed, no part ie detected on the nozzle and the machine
assumes that the tape is at an end.
Remedy: Check the feeder. Replenish the part supply. If parts have not run out check the tape end sensor
or check for tape wobbling during pickup.
------------------------------
Code: 12040102
Display: Parts Out
Used by: CP5
Cause: The small part sensor detected that small parts were not being picked. The machine is out of
parts.
Remedy: Replenish the parts supply. If parts have not run out check the tape end sensor and check the
tape for wobbling during pickup.
------------------------------
Code: 12040103
Display: Parts Out(CP5) D*** Supply(CP4)
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: When the large part check is performed(CP5),there is no part on the nozzle,and the tape end
sensor confirms that parts have run out.
when the part is inspected,no part is found on the nozzle and the machine stops when the tape end sensor
confirms that the parts have run out,or recovery is performed and the machine stops when it is unable to
pick up a part.
Remedy: Replenish the parts. If not out of parts, check the tape end sensor and whether on not there is
vibration in the tape.
------------------------------