FUJI错误代码查询.pdf - 第1209页

Remedy: Check the direction in which the parts are supplied. ------------------------------ Code: 1CC02102 Display: 1CC02102 Used by: Cause: The value input for the back light diameter is 0. Remedy: Input the correct bac…

100%1 / 5282
Display: 1CB07006
Used by:
Cause: Mark is distorted.
Remedy: Verify that the entire mark fits in the window.
------------------------------
Code: 1CB07007
Display: 1CB07007
Used by:
Cause: Mark size exceeds the tolerance range.
Remedy: Increase the tolerance value.
------------------------------
Code: 1CC01001
Display: 1CC01001
Used by:
Cause: The check window is outside of the scan area.
Remedy: Check the coordinates of the check window.
------------------------------
Code: 1CC01002
Display: 1CC01002
Used by:
Cause: The specified window size is unsuitable.
Remedy: Check the window area specified at the MCS.
------------------------------
Code: 1CC01003
Display: 1CC01003
Used by: IP3
Cause: A vision processing error occurred during the part polarity check.
Remedy: Check the direction in which the parts are supplied.
------------------------------
Code: 1CC01101
Display: 1CC01101
Used by:
Cause: The value input for the back light diameter is 0.
Remedy: Input the correct back light diameter in part data.
------------------------------
Code: 1CC02001
Display: 1CC02001
Used by:
Cause: The check window is outside of the scan area.
Remedy: Check the coordinates of the check window.
------------------------------
Code: 1CC02002
Display: 1CC02002
Used by:
Cause: The specified window size is unsuitable.
Remedy: Check the window area specified at the MCS.
------------------------------
Code: 1CC02003
Display: 1CC02003
Used by:
Cause: A vision processing error occurred during the part polarity check.
第 1208 页
Remedy: Check the direction in which the parts are supplied.
------------------------------
Code: 1CC02102
Display: 1CC02102
Used by:
Cause: The value input for the back light diameter is 0.
Remedy: Input the correct back light diameter in part data.
------------------------------
Code: 1CC03001
Display: 1CC03001
Used by:
Cause: Direction check area is improper.
Remedy: The specified area is too narrow. Increase the area size.
------------------------------
Code: 1CC03011
Display: 1CC03011
Used by:
Cause: The supply orientation of the part is wrong.
Remedy: A bump exists in the specified area (No bump check). Check the supply orientation of the part.
When checking the supply orientation also make sure that there are no errors in the area position and
area range settings.
------------------------------
Code: 1CC03021
Display: 1CC03021
Used by:
Cause: The supply orientation of the part is wrong.
Remedy: A bump does not exist in the specified area (Bump check). Check the supply orientation of the
part. When checking the supply orientation also make sure that there are no errors in the area position
and area range settings.
------------------------------
Code: 1CC03022
Display: 1CC03022
Used by:
Cause: The supply orientation of the part is wrong.
Remedy: Either a bump exists in the specified area or the verified bump that was found did not fit with a
bump that was too small. Check the supply orientation of the part. When checking the supplyorientation
also make sure that there are no errors in the area position and area range settings.
------------------------------
Code: 1CC04001
Display: 1CC04001
Used by:
Cause: The mark check position (area) is outside the body.
Remedy: Enter the correct mark check position (area) coordinates.
------------------------------
Code: 1CC04002
Display: 1CC04002
Used by:
Cause: Mark check area is improper.
Remedy: Enter the correct mark check area coordinates. This error occurs when the X1 and X2, or Y1
and Y2 values are the same.
------------------------------
第 1209 页
Code: 1CC04003
Display: 1CC04003
元件的方向不对。(XP242)
Used by: XP242
Cause: 元件的方向不对。
Remedy: 请确认元件的供应方向。请确认定位点检查位置·范围。
------------------------------
Code: 1CC04004
Display: 1CC04004
Used by:
Cause: Incorrect setting value in the Part data's Fst_Pin_check_data item (for MCS), or in the Check
Mode algorithm (for F4G).
Remedy: Enter "0, 4, or 5" at the part data's Fst_pin_check_data item (for MCS), or at the Check mode
algorithm (For F4G).
For the CUT mode, enter "0" at the algorithm. For the MARK mode, enter "4" or "5".
------------------------------
Code: 1CC05001
Display: 1CC05001
Used by:
Cause: The mark check area (range) is outside the body of the part.
Remedy: Correct the coordinates of the mark check area (range).
------------------------------
Code: 1CC05002
Display: 1CC05002
Used by:
Cause: Invalid setting for the mark check range.
Remedy: This error occurs if X1 and X2 are the same or smaller, or if Y1 and Y2 are the same or smaller.
The smallest range is five pixels. Ensure the setting is five pixels or greater.
------------------------------
Code: 1CC05003
Display: 1CC05003
Used by:
Cause: The part orientation is not correct.
Remedy: Check the feeding direction of the part.Check the mark check area (range).
------------------------------
Code: 1CC06001
Display: 1CC06001
Used by:
Cause: Failed to register the 2D code object.
Remedy: This error occurs when an attempt is made to create an object without deleting the old one. This
is a rarely occurring error. There could be a problem with the vision system. Cut and then resupply power
to the machine. If this does not rectify the problem, contact Fuji. Obtain a trace report.
------------------------------
Code: 1CC06002
Display: 1CC06002
Used by:
Cause: Failed to delete the 2D code object.
Remedy: This error occurs when an attempt is made to delete an object when no registered object exists.
This is a rarely occurring error. There could be a problem with the vision system. Cut and then resupply
power to the machine. If this does not rectify the problem, contact Fuji. Obtain a trace report.
------------------------------
第 1210 页