FUJI错误代码查询.pdf - 第2231页

Used by: Cause: The nozzle data file referred to in the specified production program was read and a format error was detected in the machine-type "BLOCK" in "UNIT", "NOZZLE". This report is …

100%1 / 5282
------------------------------
Code: 51??1511
Display: "FILESTRUCT" not entered in the nozzle data file.
Used by:
Cause: There is no entry for "FILESTRUCT" in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified
nozzle data file.
Remedy: "FILESTRUCT" is a mandatory item.
------------------------------
Code: 51??1512
Display: No "UNIT", "NOZZLE" in the nozzle data file or "UNIT", "NOZZLE" is not at the correct position.
Used by:
Cause: The nozzle data file referred to in the specified production program was read and "UNIT",
"NOZZLE" was not found or "UNIT", "NOZZLE" does not follow the correct unit. This report is made when
the nozzle data and the production program are in different files, the nozzle data referred to in the
program is required at the machine and the above error is detected. When downloading, the nozzle data
takes its default values.
Remedy: Check the setting for "UNIT", "NOZZLE" in the nozzle data file which is referred to in the
production program. Alternatively, check the setting for the "UNIT" line prior to "UNIT", "NOZZLE".
------------------------------
Code: 51??1513
Display: No "UNIT", "NOZZLE" - "BLOCK", "HEADER-" in the nozzle data file.
Used by:
Cause: The nozzle data file referred to in the specified production program was read and "BLOCK",
"HEADER-" in "UNIT", "NOZZLE" was not found. This report is made when the nozzle data and the
production program are in different files, the nozzle data referred to in the program is required at the
machine and the above error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" - "BLOCK", "HEADER-" in the nozzle data file which is
referred to in the production program.
------------------------------
Code: 51??1514
Display: No machine-type "BLOCK" in "UNIT", "NOZZLE" in the nozzle data file.
Used by:
Cause: The nozzle data file referred to in the specified production program was read and no machine-type
"BLOCK" was found in "UNIT", "NOZZLE". This report is made when the nozzle data and the production
program are in different files, the nozzle data referred to in the program is required at the machine and the
above error is detected.
Remedy: Check the setting for "BLOCK" in "UNIT", "NOZZLE" in the nozzle data file which is referred to in
the production program.
------------------------------
Code: 51??1515
Display: Format error in "UNIT", "NOZZLE" - "BLOCK", "HEADER-" in the nozzle data file.
Used by:
Cause: The nozzle data file referred to in the specified production program was read and a format error
was detected in "BLOCK", "HEADER-" in "UNIT", "NOZZLE". This report is made when the nozzle data and
the production program are in different files, the nozzle data referred to in the program is required at the
machine and the above error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" - "BLOCK", "HEADER-" in the nozzle data file which is
referred to in the production program.
------------------------------
Code: 51??1516
Display: Format error in machine-type "BLOCK" in "UNIT", "NOZZLE" in the nozzle data file.
第 2230 页
Used by:
Cause: The nozzle data file referred to in the specified production program was read and a format error
was detected in the machine-type "BLOCK" in "UNIT", "NOZZLE". This report is made when the nozzle
data and the production program are in different files, the nozzle data referred to in the program is
required at the machine and the above error is detected.
Remedy: Check the setting for the machine-type "BLOCK" in "UNIT", "NOZZLE" in the nozzle data file
referred to in the production program.
------------------------------
Code: 51??1520
Display: No "UNIT", "NOZZLE" or "UNIT", "NOZZLE" was not found at the correct place.
Used by:
Cause: "UNIT", "NOZZLE" was not found in the specified production program or "UNIT", "NOZZLE" does
not follow the correct unit. This report is made when the nozzle data and the production program are in
the same file and the above error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" in the production program. Alternatively, check the
setting for the "UNIT" line prior to "UNIT", "NOZZLE".
------------------------------
Code: 51??1521
Display: No "BLOCK" in "UNIT", "NOZZLE".
Used by:
Cause: No "BLOCK" was found in "UNIT", "NOZZLE" in the specified production program. This report is
made when the nozzle data and the production program are in the same file and the above error is
detected. When downloading, the nozzle data takes its default values.
Remedy: Check the setting for "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 51??1522
Display: No "UNIT", "NOZZLE" - "BLOCK", "HEADER".
Used by:
Cause: "BLOCK", "HEADER-" was not found in "UNIT", "NOZZLE" in the specified production program.
This report is made when the nozzle data and the production program are in the same file and the above
error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" - "BLOCK", "HEADER-" in the production program.
------------------------------
Code: 51??1523
Display: No machine-type "BLOCK" in "UNIT", "NOZZLE".
Used by:
Cause: The machine-type block was not found in "UNIT", "NOZZLE" in the specified production program.
This report is made when the nozzle data and the production program are in the same file and the above
error is detected. When downloading, the nozzle data takes its default values.
Remedy: Check the setting for the machine-type "BLOCK" in "UNIT", "NOZZLE" in the production
program.
------------------------------
Code: 51??1524
Display: "UNIT", "NOZZLE" - "BLOCK", "HEADER-" format error.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a format error was detected
in "BLOCK", "HEADER-". This report is made when the nozzle data and the production program are in the
same file and the above error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" - "BLOCK", "HEADER" in the production program.
------------------------------
Code: 51??1525
第 2231 页
Display: "UNIT", "NOZZLE" machine-type "BLOCK" format error.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a format error was detected
in the machine-type "BLOCK". This report is made when the nozzle data and the production program are
in the same file and the above error is detected.
Remedy: Check the setting for machine-type "BLOCK" in "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 51??1530
Display: No item definition line for machine-type "BLOCK" in "UNIT", "NOZZLE".
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and the machine-type "BLOCK"
item definition line was not found.
Remedy: Check the setting for the item definition line for the machine-type "BLOCK" in the production
program's "UNIT", "NOZZLE".
------------------------------
Code: 51??1531
Display: "GCCNN" item not defined.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a description for "GCCNN" in
the item declaration line in the machine-type "BLOCK" was not found.
Remedy: Check the setting for "GCCNN" in the item declaration line for the machine-type "BLOCK" in
"UNIT", "NOZZLE" in the production program. "GCCNN" is a mandatory item.
------------------------------
Code: 51??1532
Display: "GNAMN"item not defined.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a description for "GNAMN"
in the item declaration line in the machine-type "BLOCK" was not found.
Remedy: Check the setting for "GNAMN" in the item declaration line for the machine-type "BLOCK" in
"UNIT", "NOZZLE" in the production program. "GNAMN" is a mandatory item.
------------------------------
Code: 51??1550
Display: There is "UNIT", "NOZZLE".
Used by:
Cause: There is a "UNIT", "NOZZLE" entry in the specified production program even though "UNIT",
"NOZZLE" was specified as being separate. At downloading, the "UNIT", "NOZZLE" entry in the program is
ignored.
Remedy: Check the "UNIT", "NOZZLE" setting in the production program and the "FILESTRUCT" setting in
"UNIT", "STRUCT".
------------------------------
Code: 51??1551
Display: "UNIT", "NOZZLE" is repeated.
Used by:
Cause: "UNIT", "NOZZLE" is repeated in the production program. When downloading, the first "UNIT",
"NOZZLE" is valid.
Remedy: Check the setting for "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 51??1552
Display: Cannot find nozzle file setting line.
Used by:
Cause: The line for setting the nozzle file at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the